Barnett Engineering ARU CV2 instruction manual Exit

Page 39

Voice Storage and Configuration with the Telset

4-6

Cv2: "Enter Program Code"

￿￿￿ Edit Directories

Cv2: "Enter Directory Code"

￿￿￿ Speak Directory Codes

Cv2: Speaks the list of Directory Codes described previously

￿￿￿, ￿￿￿ ... ￿￿￿ Select Directory

Cv2: "Directory One Line One is DIAL 2559544 WAIT 3 VOICE"

￿￿￿ Change Current Entry

Cv2: "beep"

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Cv2: "Directory One Line One is DIAL 2559544 WAIT 5 VOICE"

￿￿￿ Delete Entry

Cv2: "beep"

Cv2: "Directory One Line One is DIAL 2559544 DTMF 1234 VOICE"

￿￿￿ Insert Before Current Entry

Cv2: "beep"

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Cv2: "Directory One Line One is DIAL 2559544 VOICE"

￿￿ Accept

Cv2: "beep"

Cv2: "Directory One Line Two is DIAL 2559598 VOICE" or

Cv2: "Directory Two Line One is ..." (next directory if current one is done)

￿￿￿ Exit

￿￿￿ Exit

￿￿￿ Record Sites and Groups

Cv2: "Site ID is Ajax Compressor Station"

￿￿￿ Record

Cv2: "beep"

You: "Acme Pump Station"

Cv2: "Site ID is Acme Pump Station"

B1272M001

BARNETT ENGINEERING LTD.

ProTalk Cv2

Image 39
Contents 1272M001 3UR7DONContents Cv2 Capabilities What constitutes an alarm?Way in which the Cv2 processes alarms is shown in Figure How are alarms processed?What actions should occur when an alarm is detected? How do you want to respond to an alarm call? What if an alarm is not acknowledged? What do you want the Cv2 to do when you call it?Sending remote control commands Troubleshooting IndicatorsAre the inputs connected properly? Antenna requirements MountingPackaged model Ground closure alarm signal Input port connectionsStand-alone model 2 +12 volt alarm signal 3 +5 volt alarm signalAnalog input Output port connections Configuration programming connectionStand-alone Cv2 PC requirements Installing the programStarting the configuration program Desktop and how to access programming functionsGroups File OperationsHardware GeneralHardware section Configuring the Cv2Directories ProgrammingWatchdog Input Interval InputTotalizer Input On/Off Output Timed OutputPoints section Common Settings for Points Port Selection Using GroupPoint Name Dtmf Tag EnabledAlarm State Digital and Watchdog PointsClear Code UnitsAnalog Point Calibrate Binary ValuesDecimal Values Hysteresis On/Off Output PointDtmf On Code Dtmf Off Code Timed Output PointGroup section Acknowledge Code Enable This GroupEnable Auto Ack Group NameLong Timer Enable Ack RequestTimers Short TimerAcknowledge Received Alarm ActiveNew Alarm Special Function OutputsWait DialAnswer Auto AckAlert VoiceSite Name SignalAccess Code DeleteShift Change Code Temporary Acknowledge TimeCall Progress Configuration Data Voice MessagesVocabulary Setup AccessCommands Dial Cv2 Site ID is Ajax Compressor Station Cv2 Electrical on or Electrical OFF Telset Programming Summary Exit Record Points Query NAM Programmable Features SpecificationsOptions TelephoneWarranty