Barnett Engineering ARU CV2 instruction manual Cv2 Site ID is Ajax Compressor Station

Page 36

Voice Storage and Configuration with the Telset

4-3

If a sequence is entered without a Voice command, the Cv2 will add the word “Warning” when it speaks the line.

3UU Delete current entry

Cv2: “beep”

This command will remove the selected line from the directory. If there are any lines following the deleted line, they will be moved up to fill in the empty line created by this command. The Cv2 will respond with the new setting for this line.

Cv2: “Directory One Line One is DIAL 2559544 DTMF 1234 VOICE”

(Former entry for line 2)

‘Empty’ will be spoken if there are no entries for this line. You can either accept the new entry or perform one of the other editing functions.

4UU Insert before current entry

Cv2: “beep”

This command will place a new line entry in the selected directory line and move all of the lines, including the current setting for this line down by one line. The new setting will be spoken after the entry is complete.

Cv2: “Directory One Line One is DIAL 2559544 VOICE” (new entry)

Entering the new line is done in the same way as changing the current entry described previously. You can either accept the new entry or perform one of the other editing functions.

#UU Exit

The Exit command will return the Cv2 to the ‘Enter Directory’ prompt.

UUAccept

Accepting an entry advances the selection to the next line in the directory. The Cv2 will speak the line and wait for a command.

#UU Exit and return to the ‘Enter Program Code’ prompt.

UUExit and return to the ‘Enter Program Code’ prompt.

1UU - Record or Play Back Site ID and Group Voices

Cv2: “Site ID is Ajax Compressor Station

(The first time the site ID, or any other voice message, is programmed, the Cv2 will have either no voice message or a factory test message.)

To record the new site ID, press 2UU and speak the desired name after the prompt ‘beep’ is returned.

The Cv2 detects when you stop speaking, and automatically plays back the message.

B1272M001

BARNETT ENGINEERING LTD.

ProTalk Cv2

Image 36
Contents 3UR7DON 1272M001Contents What constitutes an alarm? Cv2 CapabilitiesHow are alarms processed? Way in which the Cv2 processes alarms is shown in FigureWhat actions should occur when an alarm is detected? How do you want to respond to an alarm call? What if an alarm is not acknowledged? What do you want the Cv2 to do when you call it?Sending remote control commands Indicators TroubleshootingAre the inputs connected properly? Antenna requirements MountingPackaged model Ground closure alarm signal Input port connectionsStand-alone model 2 +12 volt alarm signal 3 +5 volt alarm signalAnalog input Configuration programming connection Output port connectionsStand-alone Cv2 Installing the program Starting the configuration programDesktop and how to access programming functions PC requirementsFile Operations HardwareGeneral GroupsConfiguring the Cv2 DirectoriesProgramming Hardware sectionWatchdog Input Interval InputTotalizer Input On/Off Output Timed OutputPoints section Common Settings for Points Port Selection Using GroupPoint Name Enabled Alarm StateDigital and Watchdog Points Dtmf TagClear Code UnitsAnalog Point Calibrate Binary ValuesDecimal Values Hysteresis On/Off Output PointDtmf On Code Dtmf Off Code Timed Output PointGroup section Enable This Group Enable Auto AckGroup Name Acknowledge CodeEnable Ack Request TimersShort Timer Long TimerAlarm Active New AlarmSpecial Function Outputs Acknowledge ReceivedDial WaitAuto Ack AlertVoice AnswerSignal Access CodeDelete Site NameShift Change Code Temporary Acknowledge TimeCall Progress Configuration Data Voice MessagesVocabulary Setup AccessCommands Dial Cv2 Site ID is Ajax Compressor Station Cv2 Electrical on or Electrical OFF Telset Programming Summary Exit Record Points Query NAM Specifications Programmable FeaturesTelephone OptionsWarranty