Directed Electronics SR6000 manual

Page 45

2-3 NUISANCE PREVENTION CIRCUITRY™ (NPC™) ON/OFF: NPC™ stops repeated triggering of the same zone. If one zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time of the third trigger. During that hour, if the system sees a trigger on that zone again, the system resets the one hour timer. If one hour passes and the zone has not triggered again, the zone is activated and can trigger the system again. NPC™ only monitors sensor inputs, and does not bypass the door trigger or the ignition trigger at any time. If NPC™ is turned off, the system will respond to repeated triggers on the sensor inputs and will do so indefinitely. Some states have laws regulating how many times a security system can trigger before it is consid- ered a nuisance and the vehicle is towed away.

2-4 PROGRESSIVE DOOR TRIGGER ON/OFF: The system responds to a door trigger input with a progressive response. When the door is opened with the system armed, the siren will chirp 10 times prior to the full trig- gered sequence. The door trigger is still treated as an instant trigger and closing the door quickly will not prevent full triggered sequence from occurring. If the progressive door trigger is programmed off, the full siren output will occur the moment the door is opened.

2-5 VALET PULSE COUNT 1 TO 5 PULSES: The system can be programmed to count the number of presses of the valet switch before disarming the security system. The factory default setting is one pulse. The unit can also be set for two to five pulses.

Ghost Switch option: For added security, the GRAY wire on the two-pin Valet®/Program plug can be connected to any switch in the vehicle that provides a positive (+) momentary pulse.

2-6 DOOR SENSOR BYPASS CHIRP ON/OFF: This feature controls the error chirp that is generated if the system is armed with the door trigger active. This is useful in vehicles that have a long dome light delay after the door has been closed. If the system is armed before the dome light has turned off, the security system will generate the door trigger error chirp. If this error chirp is not desired, use this feature to disable the door open error chirp. If the bypass chirp is turned off, no bypass chirp will be generated, even if a door is accidentally left open.

2-7 IGNITION CONTROLLED DOME LIGHT SUPERVISION ON/OFF: If turned on, the system will turn on the dome light for 60 seconds when the ignition is turned off. The optional dome light supervision feature must be installed as described in the Wire Connection Guide.

2-8 DOUBLE PULSE UNLOCK ON/OFF: Some vehicles require two pulses on a single wire to unlock the doors. When the double pulse unlock feature is turned on, the BLUE wire will supply two negative pulses instead of a single pulse. At the same time, the GREEN wire will supply two positive pulses instead of a single pulse. This makes it possible to directly interface with double pulse vehicles without any extra parts.

2-9 FACTORY ALARM DISARM WITH CHANNEL 2: In the default setting the factory alarm disarm output will disarm the factory alarm system any time the button(s) controlling Channel Two is pressed.

45

Image 45
Contents ProSecurity Page Table of contents Page Installation points to remember Before beginning the installationAfter the installation Locations for the control module Locations for the sirenLocations for stinger doubleguard shock sensor Locations for the status LED Locations for valet/program switchLocations for the optional starter kill relay Finding the wires you needLocations for the relay satellite Obtaining constantFinding the starter wire Finding the 12V switched ignition wireFinding the accessory wire Finding the tachometer wireFinding the wait-to-start bulb wire for diesels Finding the door pin switch circuit Finding a + parking light wireMaking your wiring connections Auxiliary harness H2, 6-pin connector Door lock harness, 3-pin connector Heavy gauge relay satellite wiring diagram Primary harness H1 wire connection guide H1/3 WHITE/BLUE remote start activation input H1/5 Green door trigger input, zone H1/8 Black chassis ground connection Secondary harness H2 wire connection guide Page Relay key satellite interface wire connection guide Connect this wire to the ignition wire in the vehicle Remote start secondary harness H3 wire con- nection guide Figure a Neutral safety switch interfaceTesting the neutral safety switch Sense wire shutting down the unit prematurely Directed Electronics, Inc. Vista, CA Bypassing GM vehicle anti-theft systems Vats Passkey III PK-3, transponder-based systems Passlock I and passlock II PL-1 and PL-2Plug-in LED and valet/program switch Shock sensor harness, 4-pin connector Programming jumpers Tach learningLight flash + Tach threshold on/offFunction Wire Color Standard configuration Transmitter configurationsPressing Multi-level security armingSystem features learn routine Tings. The sire will chirp once if connected. Pressing Menu #1 basic features Feature menusMenu #3 remote start options Menu #2 advanced featuresFeature descriptions Menu #2 advanced features Page Tion from 1-60 minutes Page Nuisance prevention circuitry Valet modeTable of zones Timer modeShutdown diagnostics To perform shutdown diagnosticsLong term event history Safety check Alarm troubleshooting TroubleshootingRemote start troubleshooting Page Wiring quick reference guide Quick reference guide Get Started Get Protected