On-Q/Legrand HMS 1100 Duress Code, Panic Switches, Area Arming, Manager Code, User Code

Page 21

Manager Code

The Manager codes can arm/disarm the security system in assigned areas, during assigned times. The Manager code can access functions that are code protected in High Security mode. Managers may also access the system from an outside telephone line.

User Code

User codes can only be used to arm and disarm the security system in assigned areas when the time assigned to that code is valid.

Duress Code

If you are forced to disarm the system against your will by an intruder, disarm it as you normally would, but use the Duress Code instead of your normal code. The system will disarm normally. No sirens will sound, no lights will flash, but the HMS 1100 will perform a silent dial out and say that this is a silent alarm.

To stop a silent dial out, turn your security system off the usual way, pressing Off key, then your code.

Panic Switches

If you have had panic switches installed, they are always armed. Pressing a panic switch will cause the alarm to activate. This alarm can only be silenced by pressing the Off key and a valid code on the console.

Area Arming

If your installer has enabled the Area feature, the security system may be armed in Area 1, and disarmed in Area 2. In fact, each area may be armed in different security modes at the same time. Each area will have its own console that will control that area independently from the other.

When disarming the security system or arming the security system in any mode, the system will automatically control all security functions in the area of that console if your code is valid for that area.

If you have a Master code, your code is valid in any area. If you are in Area 2, and wanted to arm the system in the Away mode, simply press the Away key and enter your code. The system will automatically arm Area 2. The security mode in Area 1 will not change.

If you have a code that is only valid in Area 1, you will not be able to disarm or arm Area 2.

If you are in Area 1 and wish to disarm the security system in Area 2, HMS 1100 will allow you to disarm Area 2 from the console in Area 1 if you have a Master code or a code that is valid for both areas.

From the top-level display or from the main menu, press the 2 (SEC) key on the console keypad.

Press the 0 (OFF) key, the display will show:

 

DISARM

 

ENTER CODE:

#=AREA

Press the ' # ' (AREA) key, the display will show:

 

AREA:

0=ALL

ENTER AREA

The Area number can be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of areas. If the ' 0 ' key is pressed, then all areas will be selected.

Press the 2 key then the ' # ' key. You will then be prompted to enter your code. The display will show:

DISARM AREA 2

ENTER CODE:

Page 13

Image 21
Contents HMS Page Contents Control Telephone Control Page Underwriters Laboratories Requirements Page Underwriters Laboratories UL Listing IntroductionConsole Operation Overall DescriptionDisplay Menus Normal Top-Level DisplayMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel HMS 1100 MaintenanceAreas Confirmation BeepSecurity System Operation Disarming the Security System and Silencing AlarmsArming the Security System = OFF= Night DLY Night Delay Using Shortcut Keys= Night = VacationQuick Arm = RestoreBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated #=GOTOFire Alarm Activated Gas Alarm ActivatedEmergency Keys Duress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Master Code Trouble IndicationsDuress Code Panic SwitchesArea Arming Manager CodeGoto Area Testing Your System ALC Switch Modules Control CommandsControl ModulesUnit Numbers House CodesScrolling Through Names Controlling Units Dimming and BrighteningLighting Level Timed Commands Ramp CommandScene Command Compose Internal Flags Status of a UnitControlling Outputs All On / OffScenes Leviton Scene ControlButtons HMS Thermostats Temperature ControlIf hold mode is On, Hold is shown Freeze Alarms Temperature AlarmsOutdoor Temperature Temperature Control of AppliancesStatus Through Show Events Tstat Mode Auto FAN AutoClear Text Messages MessagesShow Message MessageLog Message Clear MessageSend Message Pro-Link Phone MessageTelephone Interface Telephone ControlIn-House Phones Remote PhonesPhone Access Denied Remote Lockout Alternate MethodMain Menu Control TemperatureSecurity ButtonWhen the HMS Communicating Thermostat is entered EventsMessage Playing and Recording a Custom Phrase Playing and Recording a MessagePanic Button over the Phone # # # # # # Good-ByeEmergency Dial-Out Digital DialerVoice Dialer How the HMS 1100 Voice Dialer WorksWhat the HMS 1100 Voice Dialer Does PC Access What You Hear If Your HMS 1100 Calls YouEntering the Code Built-In Ethernet Port Connecting to Network via PC AccessController IP Address, Port Number, and Encryption Key HMS 1100 Ethernet ConnectionsDynamic DNS Local NetworkLocal / Wide Area Network Setup Configuration and Advanced Control Programming ACPSet Up Codes Duress Code Set Up TimeAdvanced Control Programming ACP = Add Programs= Show Programs Otherwise, a help screen is displayed = Delete All Programs Edit ProgramsTimes Programs Edit Programs WhenControl Unit Event / ALC Switch Press Event Buttons Security Mode Event ButtonsButton and Event Programs Zone Event Buttons Alarm Event Buttons All On/Off Event ButtonsEvent Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsEdit Program Command Program Control CommandsProgram Security Commands Program All On / All Off Commands Program Button CommandsProgram Temperature Commands Program Message CommandsEdit Program Condition Program Security Mode ConditionsProgram Control Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsSet Up Dial Dial Out Number Dial Out NumbersDial Order Set Up Arming Entry DelayExit Delay Set up Miscellaneous Format Number Description House Codes 2-16 X-10 All Off Latitude, Longitude, and Time Zone Zone NameDaylight Savings Controller Port Number Controller IP AddressEncryption Key Set Up NamesSet Up Address Set Up VoiceFire Escape Planning Underwriters Laboratories RequirementsFederal Communication Commission Notice If YOU have Trouble with Your Phones Canadian Industry Canada NoticeHMS 1100 Voice Dial-Out Planner Appendix a Dial OUT PlannerPress 9. The system will say Good-bye and hang up Instructions to Called PartyCode Char Appendix B Text Description Character CodesCode Description Appendix C Voice Description CodesFall Online Vault Page Page OnQTechnologies,Inc