On-Q/Legrand HMS 1100 owner manual Controller IP Address, Controller Port Number

Page 73

DST START WEEKEND:

FIRST SUNDAY

#=CHNG

DST END MONTH:

10

1-12 0=DISABLE



DST END WEEKEND:

#=CHNG

LAST SUNDAY

Set the value for DST Start and End Months to "0" if Daylight Savings Time does not apply to your region, or to disable this automatic time update feature.

The DST Start and End Weekend takes place on the specified Sunday (1-7) at 2:00 AM.

To change the DST Start or End Weekend, press the ' # ' key, then use the arrow keys to scroll through the list. Press the ' # ' key to make the new selection.

NUMBER

DESCRIPTION

1

First Sunday

2

Second Sunday

3

Third Sunday

4

Fourth Sunday

5

Last Sunday

6

Next to Last Sunday

7

Third from Last Sunday

Controller IP Address

The controller’s local network IP address is used to identify the HMS 1100 controller on the network. To view and assign the controller’s local network IP address, from the Set Up menu, press the 6 (MISC) key. Using the down arrow key (), scroll to the following menu item:

IP ADDRESS 192.168.0.101



The format of the IP address is a 32-bit numeric address written as four numbers separated by periods. An IP address has two components, the network address, and the host address. The first two numbers (e.g. 192.168) represent the Class B network address and must be the same as the first two numbers of your local network. The second two numbers (e.g. 0.101) identify a particular host on the local network and may be assigned at random as long as each device on the local network has a unique address. Each number can be 0 to 255. Enter the 1, 2, or 3 digit number followed by the “#” key to move to the next number. After the 4th number has been entered, press the “#” key to store the IP address.

Controller Port Number

The controller’s local network port number identifies the logical channel to the HMS 1100 controller. For example, port 80 is used for HTTP traffic; the controller’s local network port number is used for HMS-Link traffic. To view and assign the controller’s local network port number, from the previous Setup item (IP ADDRESS), press the down arrow key ().

PORT NUMBER

4369

0-65535

 



In most installations, the default port number can remain the same. Port numbers range from 0 to 65535. To change the port number, enter the new port number followed by the “#” key to store the port number. Port numbers 0 to 1024 are reserved for designated services and should not be used.

Page 65

Image 73
Contents HMS Page Contents Control Telephone Control Page Underwriters Laboratories Requirements Page Underwriters Laboratories UL Listing IntroductionConsole Operation Overall DescriptionDisplay Menus Normal Top-Level DisplayMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel HMS 1100 MaintenanceAreas Confirmation BeepSecurity System Operation Disarming the Security System and Silencing AlarmsArming the Security System = OFF= Night DLY Night Delay Using Shortcut Keys= Night = VacationQuick Arm = RestoreBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated #=GOTOGas Alarm Activated Fire Alarm ActivatedEmergency Keys Alarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Master Code Trouble IndicationsDuress Code Panic SwitchesArea Arming Manager CodeGoto Area Testing Your System ALC Switch Modules Control CommandsControl ModulesUnit Numbers House CodesScrolling Through Names Dimming and Brightening Controlling UnitsLighting Level Ramp Command Timed CommandsScene Command Compose Internal Flags Status of a UnitControlling Outputs All On / OffScenes Leviton Scene ControlButtons HMS Thermostats Temperature ControlIf hold mode is On, Hold is shown Freeze Alarms Temperature AlarmsOutdoor Temperature Temperature Control of AppliancesStatus Through Show Events Tstat Mode Auto FAN AutoClear Text Messages MessagesShow Message MessageLog Message Clear MessageSend Message Pro-Link Phone MessageTelephone Interface Telephone ControlIn-House Phones Remote PhonesAlternate Method Phone Access Denied Remote LockoutMain Menu Control TemperatureSecurity ButtonEvents When the HMS Communicating Thermostat is enteredMessage Playing and Recording a Custom Phrase Playing and Recording a MessagePanic Button over the Phone # # # # # # Good-ByeEmergency Dial-Out Digital DialerHow the HMS 1100 Voice Dialer Works Voice DialerWhat the HMS 1100 Voice Dialer Does What You Hear If Your HMS 1100 Calls You PC AccessEntering the Code Built-In Ethernet Port Connecting to Network via PC AccessController IP Address, Port Number, and Encryption Key HMS 1100 Ethernet ConnectionsDynamic DNS Local NetworkLocal / Wide Area Network Configuration and Advanced Control Programming ACP SetupSet Up Codes Duress Code Set Up Time= Add Programs Advanced Control Programming ACP= Show Programs Otherwise, a help screen is displayed = Delete All Programs Edit ProgramsTimes Programs Edit Programs WhenSecurity Mode Event Buttons Control Unit Event / ALC Switch Press Event ButtonsButton and Event Programs Zone Event Buttons All On/Off Event Buttons Alarm Event ButtonsEvent Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsProgram Control Commands Edit Program CommandProgram Security Commands Program All On / All Off Commands Program Button CommandsProgram Temperature Commands Program Message CommandsEdit Program Condition Program Security Mode ConditionsProgram Control Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsSet Up Dial Dial Out Numbers Dial Out NumberDial Order Entry Delay Set Up ArmingExit Delay Set up Miscellaneous Format Number Description House Codes 2-16 X-10 All Off Zone Name Latitude, Longitude, and Time ZoneDaylight Savings Controller Port Number Controller IP AddressEncryption Key Set Up NamesSet Up Address Set Up VoiceFire Escape Planning Underwriters Laboratories RequirementsFederal Communication Commission Notice If YOU have Trouble with Your Phones Canadian Industry Canada NoticeHMS 1100 Voice Dial-Out Planner Appendix a Dial OUT PlannerPress 9. The system will say Good-bye and hang up Instructions to Called PartyCode Char Appendix B Text Description Character CodesCode Description Appendix C Voice Description CodesFall Online Vault Page Page OnQTechnologies,Inc