House Codes
All of your X-10 modules, controlled by your HMS 1100, must be set to a House Code. A House Code can have 16 unit numbers. The House Code is set on each module using a dial. House codes are letters A through P.
Unit Numbers
Each module has its own Unit Number. Any unit number that is not being used for an ALC Switch Module may be used for an X-10 Module. ALC Switch Modules and X-10 Modules can not be assigned to the same unit number.
Each ALC switch module must have a unique address. ALC switch modules on the same branch can NOT have the same address. ALC Modules have 31 possible addresses, 1 through 31.
More than one X-10 Module can have the same unit number if you want to control multiple lights with the same unit number. X-10 Modules have 16 possible unit numbers, 1 through 16.
HMS 1100 systems have 511 unit numbers. They consist of ALC and X-10 module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows:
HMS | 1100 | Modules / Output |
Unit Numbers | Unit Numbers |
1 | - 16 | X-10 modules 1 - 16, House Code X |
17 | - 32 | X-10 modules 1 - 16, House Code X+1 |
(1 | - 31) | ALC addresses 1-31, Module 1 - Branch 1 * |
33 | - 48 | X-10 modules 1 - 16, House Code X+2 |
49 | - 64 | X-10 modules 1 - 16, House Code X+3 |
(33 | - 63) | ALC addresses 1-31, Module 1 - Branch 2 * |
65 | - 80 | X-10 modules 1 - 16, House Code X+4 |
81 | - 96 | X-10 modules 1 - 16, House Code X+5 |
(65 | - 95) | ALC addresses 1-31, Module 1 - Branch 3 * |
97 | - 112 | X-10 modules 1 - 16, House Code X+6 |
113 | - 128 | X-10 modules 1 - 16, House Code X+7 |
(97 | - 127) | ALC addresses 1-31, Module 1 - Branch 4 * |
129 | - 144 | X-10 modules 1 - 16, House Code X+8 |
145 | - 160 | X-10 modules 1 - 16, House Code X+9 |
(129 | - 159) | ALC addresses 1-31, Module 2 - Branch 1 * |
161 | - 176 | X-10 modules 1 - 16, House Code X+10 |
177 | - 192 | X-10 modules 1 - 16, House Code X+11 |
(161 | - 191) | ALC addresses 1-31, Module 2 - Branch 2 * |