On-Q/Legrand HMS 1100 owner manual Tstat Mode Auto FAN Auto, Show Events

Page 37
Event Log
ENERGY COST: MID
6= ENERGY (ENERGY COST)

You may enter a unit number to start displaying the status with that unit, or simply press the down arrow key to scroll through the list of temperature zones. The status display is as shown under Temperature Control, except that now the arrow keys may be used to continue scrolling.

TSTAT

1

MODE:

AUTO FAN: AUTO

At this point, you may press the ' # ' key to control the temperature zone as specified under Temperature Control.

The Energy Cost Status menu allows you to view the current energy rate in use.

The Energy Cost will display Lo, Mid, Hi or Crit (for critical) energy rates.

The Event Log records the 250 most recent significant security system Events (happenings) and trouble conditions in the system. When a new event occurs, the oldest one is lost.

The following Events, along with the time and date of their occurrence are recorded in the Event Log when they occur:

All Security system Armings and disarmings (Off, Day, Night, Away, and Vacation), and user name. All zones bypassed or restored by the user, and user name.

Any zone automatically bypassed by the system. Any zone tripped while the security system is armed.

Any trouble condition (zone, battery, fuse, AC power, or phone).

The restoration of any trouble condition (the trouble condition ceased to occur). Any Remote Telephone Access, Remote Access Denied, or Remote PC Access.

Show Events

To view your event log, from the top-level display or from the main menu, press the 7 key, then enter your code. The arrow keys may be used to scroll through the event log, starting with the most recent event.

Each event log entry displays the time and date on the top line and a description of the event on the bottom line:

7:15

PM

5/8

USER

NAME

AWAY

For trouble conditions, the event log will show the zone name or specific trouble condition and "TROUBLE":

10:59 AM 5/8

BATTERYTROUBLE

For trouble restorations, the event log will show the zone name or specific trouble condition and "TRBL RST":

11:57 AM

5/8

BATTERY

TRBL RST

The system records each remote access. A remote phone access is when someone calls into the system from an outside phone line. Remote phone access is also recorded if the system phones out in response to an alarm and the called party enters a code. The event log displays the code used to access the system and "REM ACCESS":

12:05 PM

5/8

USER NAME

REM ACCESS

Page 29

Image 37
Contents HMS Page Contents Control Telephone Control Page Underwriters Laboratories Requirements Page Underwriters Laboratories UL Listing IntroductionConsole Operation Overall DescriptionDisplay Menus Normal Top-Level DisplayMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel HMS 1100 MaintenanceAreas Confirmation BeepSecurity System Operation Disarming the Security System and Silencing AlarmsArming the Security System = OFF= Night DLY Night Delay Using Shortcut Keys= Night = VacationQuick Arm = RestoreBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated #=GOTOGas Alarm Activated Fire Alarm ActivatedEmergency Keys Alarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Master Code Trouble IndicationsDuress Code Panic SwitchesArea Arming Manager CodeGoto Area Testing Your System ALC Switch Modules Control CommandsControl ModulesUnit Numbers House CodesScrolling Through Names Dimming and Brightening Controlling UnitsLighting Level Ramp Command Timed CommandsScene Command Compose Internal Flags Status of a UnitControlling Outputs All On / OffScenes Leviton Scene ControlButtons HMS Thermostats Temperature ControlIf hold mode is On, Hold is shown Freeze Alarms Temperature AlarmsOutdoor Temperature Temperature Control of AppliancesStatus Through Show Events Tstat Mode Auto FAN AutoClear Text Messages MessagesShow Message MessageLog Message Clear MessageSend Message Pro-Link Phone MessageTelephone Interface Telephone ControlIn-House Phones Remote PhonesAlternate Method Phone Access Denied Remote LockoutMain Menu Control TemperatureSecurity ButtonEvents When the HMS Communicating Thermostat is enteredMessage Playing and Recording a Custom Phrase Playing and Recording a MessagePanic Button over the Phone # # # # # # Good-ByeEmergency Dial-Out Digital DialerHow the HMS 1100 Voice Dialer Works Voice DialerWhat the HMS 1100 Voice Dialer Does What You Hear If Your HMS 1100 Calls You PC AccessEntering the Code Built-In Ethernet Port Connecting to Network via PC AccessController IP Address, Port Number, and Encryption Key HMS 1100 Ethernet ConnectionsDynamic DNS Local NetworkLocal / Wide Area Network Configuration and Advanced Control Programming ACP SetupSet Up Codes Duress Code Set Up Time= Add Programs Advanced Control Programming ACP= Show Programs Otherwise, a help screen is displayed = Delete All Programs Edit ProgramsTimes Programs Edit Programs WhenSecurity Mode Event Buttons Control Unit Event / ALC Switch Press Event ButtonsButton and Event Programs Zone Event Buttons All On/Off Event Buttons Alarm Event ButtonsEvent Buttons Message Event Buttons Pro-Link Miscellaneous Event ButtonsProgram Control Commands Edit Program CommandProgram Security Commands Program All On / All Off Commands Program Button CommandsProgram Temperature Commands Program Message CommandsEdit Program Condition Program Security Mode ConditionsProgram Control Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsSet Up Dial Dial Out Numbers Dial Out NumberDial Order Entry Delay Set Up ArmingExit Delay Set up Miscellaneous Format Number Description House Codes 2-16 X-10 All Off Zone Name Latitude, Longitude, and Time ZoneDaylight Savings Controller Port Number Controller IP AddressEncryption Key Set Up NamesSet Up Address Set Up VoiceFire Escape Planning Underwriters Laboratories RequirementsFederal Communication Commission Notice If YOU have Trouble with Your Phones Canadian Industry Canada NoticeHMS 1100 Voice Dial-Out Planner Appendix a Dial OUT PlannerPress 9. The system will say Good-bye and hang up Instructions to Called PartyCode Char Appendix B Text Description Character CodesCode Description Appendix C Voice Description CodesFall Online Vault Page Page OnQTechnologies,Inc