Bryant manual 580D036-072 579F180,216 580D090-150 579F240,300, Features/Benefits

Page 1

COMMERCIAL

Model 579F/580D

SINGLE PACKAGE ROOFTOP

Sizes 036-300

GAS HEATING/ELECTRIC COOLING UNITS

3 to 25 Tons

 

 

580D036-072

579F180,216

580D090-150

579F240,300

Standard-Efficiency Rooftop Units with:

·Exclusive integrated gas control board with diagnostics

·Alumagard™ heat exchanger coating

·Induced-draft fan for gas combustion

·Tubular, dimpled heat exchangers

·Pre-painted galvanized steel cabinet for long life and quality appearance

·Commercial strength baserails with built-in rigging capability

·Convertible design for horizontal supply/return

·Non-corrosive, sloped condensate drain pan, meets ASHRAE 62-89 (IAQ)

·Two-inch return-air ®lters

·A wide assortment of factory-installed options available, in- cluding high static drives that provide additional performance range

INTEGRATED GAS UNIT CONTROLLER (IGC) (All Models)

ÐAll ignition components are contained in the compact IGC which is easily accessible for servicing. The IGC control board, designed and manufactured exclusively for Bryant rooftop units, provides built-in diagnostic capability. An LED (light-emitting di- ode) simpli®es troubleshooting by providing visual fault noti®ca- tion and system status con®rmation.

The IGC also contains an exclusive anti-cycle protection for gas heat operation. After 4 continuous cycles on the unit high- temperature limit switch, the gas heat operation is disabled, and an error code is issued. This feature greatly improves reliability of the rooftop unit.

FEATURES/BENEFITS

Every compact one-piece unit arrives fully assembled, charged, tested, and ready to run.

Form No. PDS 580D.36.8

Image 1
Contents 580D036-072 579F180,216 580D090-150 579F240,300 FEATURES/BENEFITSPage Table of Contents 580D036-150 Models only Model Number NomenclatureModel Number Nomenclature 579F180-300 Models only ARI* Capacity Ratings Heating Capacities and Efficiencies Ð 580D036-150 ARI* Capacity RatingsHeating Capacities and Efficiencies Ð 579F180-300 Rise EfficiencyUnit Size 580D Physical Data Ð 580D036-072Unit Size 580D Medium LOW/MEDIUM High Heat Physical Data Ð 580D036-072090 102 120 150 Nominal Capacity tons Physical Data Ð 580D090-150Quantity...Diameter Motor Hp...Rpm Pulley Center Line Distance StdUnit Size 580D LOW/MEDIUM High Heat Hihg Heat Medium Heat Physical Data Ð 580D090-150Unit Size 579F Physical Data Ð 579F180-300Unit Size 579F Physical Data Ð 579F180-300LOW/HIGH Heat Option ACCESSORY² Options and AccessoriesHead Pressure Control Head Pressure Control Speed Control 180,216Time Guard II Control Options and AccessoriesDurablade Economizer SizesAccusensor Control Power Exhaust 180-300 Shown Accusensor SensorOnly ThermostatUnit Base Unit Dimensions Ð 580D036-072Unit Corner Weight Dimensions Base Unit Dimensions Ð 580D090-150486 220 636 288 Base Unit Dimensions Ð 579F180,216Dimension Base Unit Dimensions Ð 579F240,300Roof Curb Ð 580D036-072 Accessory DimensionsRoof Curb Ð 580D090-150 Accessory DimensionsPKG. NO. REF Curb Description Height Dimensions degrees and inchesUnit DEG 579FPower Exhaust 579F180-300 Horizontal Supply/Return Adapter Installation 579F180-300Accessory Curb Description Package no Height Pre-Assembled, High StaticII Select Unit Based on Required Cooling Capacity Selection Procedure with 579F180 exampleSHC Performance Data Cooling CapacitiesCooling Capacities Performance Data580D120 10 Tons Performance Data Cooling Capacities580D150 121¤2 Tons 4500/0.08 5250/0.10 6000/0.11 6750/0.12 7500/0.14 Condenser 579F180 15 Tons Temp F Air Entering Evaporator Ð Cfm/BF579F216 18 Tons 5400/0.06 6000/0.07 7200/0.08 9000/0.09579F300 25 Tons 579F240 20 Tons Temp F Air Entering Evaporator Ð Cfm/BF7000/0.03 8750/0.05 10,000/0.07 11,250/0.09 580D036 3 Tons Ð Standard Motor Direct Drive FAN Performance Ð 580D036-150 Vertical Discharge UnitsFiop 580D036 3 Tons Ð Alternate Motor Belt Drive580D048 4 Tons Ð Alternate Motor Belt Drive 580D048 4 Tons Ð Standard Motor Direct Drive580D060 5 Tons Ð Alternate Motor Belt Drive 580D060 5 Tons Ð Standard Motor Direct DriveRpm Bhp Watts 1800 580D072 6 Tons Air¯ow External Static Pressure in. wg2600 1562Rpm Bhp Watts 2250 580D090 71¤2 Tons Air¯ow External Static Pressure in. wg2550 3100Rpm Bhp Watts 2550 580D102 81¤2 Tons Air¯ow External Static Pressure in. wg891 2188 3300 904 2300 3400Rpm Bhp Watts 3000 580D120 10 Tons Air¯ow External Static Pressure in. wg4300 985Rpm Bhp Watts 3750 580D150 121¤2 Tons Air¯ow External Static Pressure in. wg5100 5200FAN Performance Ð 580D036-150 Horizontal Discharge Units Rpm Bhp Watts 1200 569 189 641 1989 1466 2171 Bhp Brake Horsepower Input to Fan299 761 357 859 483 901 546 943 609 1300 604 231 673 352 788 410 887 546 928 615 968 683 1400 640 284 7051392 Medium Speed High Speed 208 230, 460, 575 230,460, 5751365 2038 1426 1331 1986 1400 2227 14611514 15361496 2240 1529 1603894 997 3055 1040 3333 Bhp Brake Horsepower Input to Fan882 895Rpm Bhp Watts 2550 669 627 867 692 1056 754 1062 3676 1102 3860 Bhp Brake Horsepower Input to Fan783 8121008 962973 10191166 Bhp Watts 37501178 1131FAN Performance Ð 579F180-300 Units Performance Data FAN Performance Ð 579F180-300 Units 579F240 20 Tons Air¯ow External Static Pressure in. wg 10,000 Bhp Brake Horsepower Input to FanRpm Bhp Watts 6000 9500579F300 25 Tons Air¯ow 10,500 11,000 11,250 Bhp Brake Horsepower Input to FanRpm Bhp Watts 500 3507Sound Weighted Octave Bands Unit Rating Sound Power Total UnitAIR Quantity Limits Unit Minimum CFM Maximum CFMACCESSORY/FIOP Static PRESSURE* in. wg − 579F180-300 ACCESSORY/FIOP Static PRESSURE* in. wg − 580D090-150Component CFM Unit Motor Pulley Turns OpenBtuh Nominal Altitude COMPENSATION* ÐNominal Input InputAltitude COMPENSATION* Ð 580D090-150 Fan Performance Using Accessory Power Exhaust 579F180-300EVAPORATOR-FAN Motor Efficiency Altitude Derating FACTOR* Ð ALL UnitsMaximum Unit EVAPORATOR-FAN Acceptable EVAPORATOR-FAN Motor PerformanceContinuous Operating AMP Draw BHP 580D036RLA LRA FLA MCA MOCP² Electrical Data Ð 580D036-150Electrical Data Ð 579F180-300 Vertical Discharge Ducting Typical Piping and Wiring Ð 580D036-150Horizontal Discharge Ducting NEC Ð National Electrical Code579F180 shown Typical Piping and Wiring Ð 579F180-300Typical Wiring Schematic Ð 580D036-150 Typical Wiring Schematic 579F240-300, 460-v shown PRI AHAIDM IFCOperating Sequence ControlsCooling, Units With Parablade Economizer 580D036-072 Controls580D036-150 Application DataApplication Data Part 1 Ð General Guide Specifications Ð 580D036-150Guide Specifications Ð 580D036-150 Guide Specifications Ð 580D036-150 Guide Specifications Ð 579F180-300 Guide Specifications Ð 579F180-300 Copyright 1998 Bryant Heating & Cooling Systems