Bryant 580D Aha, Pri, Idm, Cap, Ifcb, Sen,Sn, Clo, Comp, Igc, Tdr, Tran, Lor, Lps, Equip, Mat

Page 62

TYPICAL WIRING SCHEMATIC (579F240-300, 460-v shown) (cont)

LEGEND FOR TYPICAL WIRING SCHEMATICS

AHA

Ð Adjustable Heat Anticipator

HV

Ð High Voltage

PRI

Ð Primary

BKR W/AT Ð Breaks with Amp Turns

I

Ð Ignitor

QT

Ð Quadruple Terminal

BR

Ð Burner Relay

IDM

Ð Induced-Draft Motor

R

Ð Relay

C

Ð Contactor, Compressor

IFC

Ð Indoor (Evaporator)

RS

Ð Rollout Switch

CAP

Ð Capacitor

 

Fan Contactor

SR

Ð Solenoid Relay

CB

Ð Circuit Breaker

IFCB

Ð Indoor (Evaporator)

SEN,SN

Ð Sensor

CC

Ð Cooling Compensator

 

Fan Circuit Breaker

SW

Ð Switch

CH

Ð Crankcase Heater

IFM

Ð Indoor (Evaporator)

TB

Ð Terminal Block

CLO

Ð Compressor Lockout

 

Fan Motor

TC

Ð Thermostat Cooling

COMP

Ð Compressor Motor

IGC

Ð Integrated Gas Unit Controller

TDR

Ð Time-Delay Relay

CR

Ð Control Relay

IP

Ð Internal Protector

TH

Ð Thermostat Heating

CT

Ð Current Transformer

L

Ð Light

TRAN

Ð Transformer

DM

Ð Damper Motor

LLSV Ð Liquid Line Solenoid Valve

 

Terminal (Marked)

DU

Ð Dummy Terminal

LOR

Ð Lockout Relay

 

 

 

EC

Ð Enthalpy Control

LPS

Ð Low-Pressure Switch

 

Terminal (Unmarked)

ER

Ð Economizer Relay

LS

Ð Limit Switch

 

Terminal Block

EQUIP

Ð Equipment

MAT

Ð Mixed-Air Thermostat

 

EPS

Ð Emergency Power Supply

MGV

Ð Main Gas Valve

 

Splice

 

(9 v Battery)

MTR

Ð Motor

 

FPT

Ð Freeze Protection Thermostat

OAT

Ð Outdoor-Air Thermostat

 

Factory Wiring

FU

Ð Fuse

OFC

Ð Outdoor (Condenser)

 

 

Field Wiring

GND

Ð Ground

 

Fan Contactor

 

 

 

To Indicate Common

GVR

Ð Gas Valve Relay

OFM

Ð Outdoor (Condenser)

 

HPS

Ð High-Pressure Switch

 

Fan Motor

 

Potential Only, Not

HS

Ð Hall Effect Sensor

PL

Ð Plug Assembly

 

To Represent Wiring

NOTES FOR 579F240-300 UNITS:

1.Compressor and fan motors thermally protected; 3-phase motors protected against primary single-phasing conditions.

2.If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent.

3.Jumpers are omitted when unit is equipped with economizer.

4.IFCB must trip amps is equal to or less than 140% full load amps, and CB1 and CB2 (156%).

5.On TRAN1 use BLK lead for 460-v power supply.

6.The CLO locks out the compressor to prevent short cycling on compressor overload and safety devices. Before replacing CLO, check these devices.

7.Number(s) indicates the line location of used contacts. A bracket over (2) numbers signi®es a single-pole, double-throw contact. An underlined number signi®es a normally closed contact. A plain (no line) number signi®es a normally open contact.

8.TDR switches 1 and 2 to be set to ON for a 3-second delay.

62

Image 62
Contents FEATURES/BENEFITS 580D036-072 579F180,216 580D090-150 579F240,300Page Table of Contents Model Number Nomenclature 580D036-150 Models onlyModel Number Nomenclature 579F180-300 Models only ARI* Capacity Ratings Heating Capacities and Efficiencies Ð 579F180-300 ARI* Capacity RatingsHeating Capacities and Efficiencies Ð 580D036-150 Rise EfficiencyPhysical Data Ð 580D036-072 Unit Size 580DPhysical Data Ð 580D036-072 Unit Size 580D Medium LOW/MEDIUM High HeatQuantity...Diameter Motor Hp...Rpm Physical Data Ð 580D090-150090 102 120 150 Nominal Capacity tons Pulley Center Line Distance StdPhysical Data Ð 580D090-150 Unit Size 580D LOW/MEDIUM High Heat Hihg Heat Medium HeatPhysical Data Ð 579F180-300 Unit Size 579FLOW/HIGH Heat Physical Data Ð 579F180-300Unit Size 579F Head Pressure Control Options and AccessoriesOption ACCESSORY² Head Pressure Control Speed Control 180,216Durablade Economizer Options and AccessoriesTime Guard II Control SizesOnly Power Exhaust 180-300 Shown Accusensor SensorAccusensor Control ThermostatBase Unit Dimensions Ð 580D036-072 UnitBase Unit Dimensions Ð 580D090-150 Unit Corner Weight DimensionsBase Unit Dimensions Ð 579F180,216 486 220 636 288Base Unit Dimensions Ð 579F240,300 DimensionAccessory Dimensions Roof Curb Ð 580D036-072Accessory Dimensions Roof Curb Ð 580D090-150Unit DEG Dimensions degrees and inchesPKG. NO. REF Curb Description Height 579FAccessory Curb Description Package no Height Horizontal Supply/Return Adapter Installation 579F180-300Power Exhaust 579F180-300 Pre-Assembled, High StaticSelection Procedure with 579F180 example II Select Unit Based on Required Cooling CapacityPerformance Data Cooling Capacities SHCPerformance Data Cooling Capacities580D150 121¤2 Tons Performance Data Cooling Capacities580D120 10 Tons 579F216 18 Tons 579F180 15 Tons Temp F Air Entering Evaporator Ð Cfm/BF4500/0.08 5250/0.10 6000/0.11 6750/0.12 7500/0.14 Condenser 5400/0.06 6000/0.07 7200/0.08 9000/0.097000/0.03 8750/0.05 10,000/0.07 11,250/0.09 579F240 20 Tons Temp F Air Entering Evaporator Ð Cfm/BF579F300 25 Tons Fiop FAN Performance Ð 580D036-150 Vertical Discharge Units580D036 3 Tons Ð Standard Motor Direct Drive 580D036 3 Tons Ð Alternate Motor Belt Drive580D048 4 Tons Ð Standard Motor Direct Drive 580D048 4 Tons Ð Alternate Motor Belt Drive580D060 5 Tons Ð Standard Motor Direct Drive 580D060 5 Tons Ð Alternate Motor Belt Drive2600 580D072 6 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 1800 15622550 580D090 71¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2250 3100891 2188 3300 580D102 81¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2550 904 2300 34004300 580D120 10 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3000 9855100 580D150 121¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3750 5200FAN Performance Ð 580D036-150 Horizontal Discharge Units 299 761 357 859 483 901 546 943 609 1300 604 231 673 1989 1466 2171 Bhp Brake Horsepower Input to FanRpm Bhp Watts 1200 569 189 641 352 788 410 887 546 928 615 968 683 1400 640 284 7051365 2038 1426 Medium Speed High Speed 208 230, 460, 575 230,460, 5751392 1331 1986 1400 2227 14611496 2240 1529 15361514 1603882 997 3055 1040 3333 Bhp Brake Horsepower Input to Fan894 895783 1062 3676 1102 3860 Bhp Brake Horsepower Input to FanRpm Bhp Watts 2550 669 627 867 692 1056 754 812973 9621008 10191178 Bhp Watts 37501166 1131FAN Performance Ð 579F180-300 Units Performance Data FAN Performance Ð 579F180-300 Units Rpm Bhp Watts 6000 10,000 Bhp Brake Horsepower Input to Fan579F240 20 Tons Air¯ow External Static Pressure in. wg 9500Rpm Bhp Watts 500 10,500 11,000 11,250 Bhp Brake Horsepower Input to Fan579F300 25 Tons Air¯ow 3507AIR Quantity Limits Sound Power Total UnitSound Weighted Octave Bands Unit Rating Unit Minimum CFM Maximum CFMComponent CFM ACCESSORY/FIOP Static PRESSURE* in. wg − 580D090-150ACCESSORY/FIOP Static PRESSURE* in. wg − 579F180-300 Unit Motor Pulley Turns OpenNominal Input Altitude COMPENSATION* ÐBtuh Nominal InputEVAPORATOR-FAN Motor Efficiency Fan Performance Using Accessory Power Exhaust 579F180-300Altitude COMPENSATION* Ð 580D090-150 Altitude Derating FACTOR* Ð ALL UnitsContinuous Operating AMP Draw BHP EVAPORATOR-FAN Motor PerformanceMaximum Unit EVAPORATOR-FAN Acceptable 580D036Electrical Data Ð 580D036-150 RLA LRA FLA MCA MOCP²Electrical Data Ð 579F180-300 Horizontal Discharge Ducting Typical Piping and Wiring Ð 580D036-150Vertical Discharge Ducting NEC Ð National Electrical CodeTypical Piping and Wiring Ð 579F180-300 579F180 shownTypical Wiring Schematic Ð 580D036-150 Typical Wiring Schematic 579F240-300, 460-v shown IDM AHAPRI IFCControls Operating SequenceControls Cooling, Units With Parablade Economizer 580D036-072Application Data 580D036-150Application Data Guide Specifications Ð 580D036-150 Part 1 Ð GeneralGuide Specifications Ð 580D036-150 Guide Specifications Ð 580D036-150 Guide Specifications Ð 579F180-300 Guide Specifications Ð 579F180-300 Copyright 1998 Bryant Heating & Cooling Systems