GUIDE SPECIFICATIONS Ð 579F180-300
PACKAGED ROOFTOP ELECTRIC COOLING UNIT WITH GAS HEAT Ð CONSTANT VOLUME APPLICATION
HVAC GUIDE SPECIFICATIONS
SIZE RANGE: 15 TO 25 TONS, NOMINAL (COOLING) 172,000 to 360,000 BTUH, NOMINAL (INPUT HEATING)
MODEL NUMBER: 579F
Part 1 Ð General
1.01SYSTEM DESCRIPTION
Unit is an outdoor rooftop mounted, electrically controlled heating and cooling unit utilizing a reciprocating semi- hermetic compressor(s) for cooling duty and gas combus- tion for heating duty. Supply air shall be discharged downward or horizontally (with horizontal supply/return curb adapter assembly), as shown on contract drawings. Standard unit shall include a manual
1.02QUALITY ASSURANCE
A.Unit
NOTE: The 579F300 is beyond the scope of the ARI cer- ti®cation program.
B.Unit shall be designed to conform to ASHRAE 15.
C.Unit shall be ETL and ETL, Canada tested and certi®ed in accordance with ANSI Z21.47 Standards as a total pack- age.
D.Roof curb shall be designed to conform to NRCA Standards.
E.Insulation and adhesive shall meet NFPA 90A require- ments for ¯ame spread and smoke generation.
F.Unit casing shall be capable of withstanding
G.Unit shall be manufactured in a facility registered to ISO 9002/BS5750, Part 2.
1.03DELIVERY, STORAGE, AND HANDLING
Unit shall be stored and handled per manufacturer's recommendations.
Part 2 Ð Products
2.01EQUIPMENT (STANDARD)
A.General:
The 579F unit shall be a factory assembled,
B.Unit Cabinet:
1.Unit cabinet shall be constructed of galvanized steel, bonderized and coated with a prepainted baked enamel
®nish.
2.Indoor blower compartment interior surfaces shall be insulated with a minimum
3.Cabinet panels shall be easily removable for servicing.
4.Filters shall be accessible through an access panel.
5.Holes shall be provided in the base rails for rigging shackles to facilitate overhead rigging.
6.Unit shall have a
C.Fans:
1.Indoor blower (evaporator fan):
a.Fan shall be belt driven. Belt drive shall include an adjustable pulley. The standard fan drive shall have a
b.Fan wheel shall be made from steel with a corro- sion resistant ®nish. It shall be a dynamically bal- anced,
2.Condenser fans shall be of the
3.
D.Compressor(s):
1.The reciprocating
2.
3.The 180 size
4.Compressors shall be on mechanically and electrically independent circuits
E.Coils:
1.Standard evaporator and condenser coils shall have copper or aluminum plate ®ns mechanically bonded to seamless internally grooved copper tubes with all joints brazed.
2.Optional precoated coils shall be coated with a
F.Heating Section:
1.
2.The heat exchanger shall be of the
3.Burners shall be of the
4.All gas piping shall enter the unit at a single location.
G.Refrigerant Components:
Refrigerant circuit components shall include:
1.Fixed expansion device with ®lter driers.
2.Service valve gage and connections on suction, dis- charge, and liquid lines.
3.Thermostatic expansion valve (size 180) or ®xed ori- ®ce feed system (sizes