Bryant manual EVAPORATOR-FAN Motor Performance, Maximum Unit EVAPORATOR-FAN Acceptable, 580D036

Page 55

PERFORMANCE DATA (cont)

EVAPORATOR-FAN MOTOR PERFORMANCE

 

 

 

MAXIMUM

MAXIMUM

 

UNIT

EVAPORATOR-FAN

UNIT

ACCEPTABLE

ACCEPTABLE

MAXIMUM

MOTOR

VOLTAGE

CONTINUOUS

OPERATING

AMP DRAW

 

 

 

 

BHP*

WATTS

 

 

 

208/230

 

 

2.9

 

Standard

460

0.34

440

1.4

580D036

 

575

 

 

1.4

 

208/230

 

 

5.4

 

 

 

 

 

Alternate

460

1.00

1000

2.3

 

 

575

 

 

2.3

 

 

208/230

 

 

3.5

 

Standard

460

0.75

850

1.8

580D048

 

575

 

 

1.8

 

208/230

 

 

5.4

 

 

 

 

 

Alternate

460

1.00

1000

2.3

 

 

575

 

 

2.3

 

 

208/230

 

 

5.9

 

Standard

460

1.20

1340

3.2

580D060

 

575

 

 

3.2

 

208/230

 

 

8.9

 

 

 

 

 

Alternate

460

1.80

1921

4.7

 

 

575

 

 

4.7

 

 

208/230

 

 

6.1

580D072

Standard

460

2.40

2120

2.7

 

 

575

 

 

2.7

 

 

208/230

 

 

6.1

580D090

Standard

460

2.40

2120

2.7

 

 

575

 

 

2.7

 

 

208/230

 

 

6.1

580D102

Standard

460

2.40

2120

2.7

 

 

575

 

 

2.7

 

 

208/230

 

 

6.1

 

Standard

460

2.40

2120

2.7

580D120

 

575

 

 

2.7

 

208/230

 

 

7.9

 

 

 

 

 

Alternate

460

2.90

2615

3.6

 

 

575

 

 

3.6

 

 

208/230

 

 

11.1

 

Standard

460

4.20

3775

5.0

580D150

 

575

 

 

5.0

 

208/230

 

 

15.0

 

 

 

 

 

Alternate

460

5.25

4400

7.4

 

 

575

 

 

7.4

579F180

Standard

208/230

4.25

3775

10.5

460

4.8

 

 

 

 

579F216

Standard

208/230

5.90

5180

15.8

460

7.9

 

 

 

 

579F240

Standard

208/230

8.70

7915

22.0

460

9.50

8640

13.0

 

 

579F300

Standard

208/230

10.20

9510

28.0

460

11.80

11,000

14.6

 

 

 

 

 

 

 

 

LEGEND

Bhp Ð Brake Horsepower

*Extensive motor and electrical testing on these units ensures that the full horsepower range of the motors can be utilized with con®dence. Using your fan motors up to the horsepower ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit war- ranty will not be affected.

NOTE: All indoor-fan motors 5 hp and larger meet the minimum effi- ciency requirements as established by the Energy Policy Act of 1992 (EPACT) effective October 24, 1997.

55

Image 55
Contents 580D036-072 579F180,216 580D090-150 579F240,300 FEATURES/BENEFITSPage Table of Contents 580D036-150 Models only Model Number NomenclatureModel Number Nomenclature 579F180-300 Models only ARI* Capacity Ratings Rise Efficiency ARI* Capacity RatingsHeating Capacities and Efficiencies Ð 580D036-150 Heating Capacities and Efficiencies Ð 579F180-300Unit Size 580D Physical Data Ð 580D036-072Unit Size 580D Medium LOW/MEDIUM High Heat Physical Data Ð 580D036-072Pulley Center Line Distance Std Physical Data Ð 580D090-150090 102 120 150 Nominal Capacity tons Quantity...Diameter Motor Hp...RpmUnit Size 580D LOW/MEDIUM High Heat Hihg Heat Medium Heat Physical Data Ð 580D090-150Unit Size 579F Physical Data Ð 579F180-300Unit Size 579F Physical Data Ð 579F180-300LOW/HIGH Heat Head Pressure Control Speed Control 180,216 Options and AccessoriesOption ACCESSORY² Head Pressure ControlSizes Options and AccessoriesTime Guard II Control Durablade EconomizerThermostat Power Exhaust 180-300 Shown Accusensor SensorAccusensor Control OnlyUnit Base Unit Dimensions Ð 580D036-072Unit Corner Weight Dimensions Base Unit Dimensions Ð 580D090-150486 220 636 288 Base Unit Dimensions Ð 579F180,216Dimension Base Unit Dimensions Ð 579F240,300Roof Curb Ð 580D036-072 Accessory DimensionsRoof Curb Ð 580D090-150 Accessory Dimensions579F Dimensions degrees and inchesPKG. NO. REF Curb Description Height Unit DEGPre-Assembled, High Static Horizontal Supply/Return Adapter Installation 579F180-300Power Exhaust 579F180-300 Accessory Curb Description Package no HeightII Select Unit Based on Required Cooling Capacity Selection Procedure with 579F180 exampleSHC Performance Data Cooling CapacitiesCooling Capacities Performance Data580D120 10 Tons Performance Data Cooling Capacities580D150 121¤2 Tons 5400/0.06 6000/0.07 7200/0.08 9000/0.09 579F180 15 Tons Temp F Air Entering Evaporator Ð Cfm/BF4500/0.08 5250/0.10 6000/0.11 6750/0.12 7500/0.14 Condenser 579F216 18 Tons579F300 25 Tons 579F240 20 Tons Temp F Air Entering Evaporator Ð Cfm/BF7000/0.03 8750/0.05 10,000/0.07 11,250/0.09 580D036 3 Tons Ð Alternate Motor Belt Drive FAN Performance Ð 580D036-150 Vertical Discharge Units580D036 3 Tons Ð Standard Motor Direct Drive Fiop580D048 4 Tons Ð Alternate Motor Belt Drive 580D048 4 Tons Ð Standard Motor Direct Drive580D060 5 Tons Ð Alternate Motor Belt Drive 580D060 5 Tons Ð Standard Motor Direct Drive1562 580D072 6 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 1800 26003100 580D090 71¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2250 2550904 2300 3400 580D102 81¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2550 891 2188 3300985 580D120 10 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3000 43005200 580D150 121¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3750 5100FAN Performance Ð 580D036-150 Horizontal Discharge Units 352 788 410 887 546 928 615 968 683 1400 640 284 705 1989 1466 2171 Bhp Brake Horsepower Input to FanRpm Bhp Watts 1200 569 189 641 299 761 357 859 483 901 546 943 609 1300 604 231 6731331 1986 1400 2227 1461 Medium Speed High Speed 208 230, 460, 575 230,460, 5751392 1365 2038 14261603 15361514 1496 2240 1529895 997 3055 1040 3333 Bhp Brake Horsepower Input to Fan894 882812 1062 3676 1102 3860 Bhp Brake Horsepower Input to FanRpm Bhp Watts 2550 669 627 867 692 1056 754 7831019 9621008 9731131 Bhp Watts 37501166 1178FAN Performance Ð 579F180-300 Units Performance Data FAN Performance Ð 579F180-300 Units 9500 10,000 Bhp Brake Horsepower Input to Fan579F240 20 Tons Air¯ow External Static Pressure in. wg Rpm Bhp Watts 60003507 10,500 11,000 11,250 Bhp Brake Horsepower Input to Fan579F300 25 Tons Air¯ow Rpm Bhp Watts 500Unit Minimum CFM Maximum CFM Sound Power Total UnitSound Weighted Octave Bands Unit Rating AIR Quantity LimitsUnit Motor Pulley Turns Open ACCESSORY/FIOP Static PRESSURE* in. wg − 580D090-150ACCESSORY/FIOP Static PRESSURE* in. wg − 579F180-300 Component CFMInput Altitude COMPENSATION* ÐBtuh Nominal Nominal InputAltitude Derating FACTOR* Ð ALL Units Fan Performance Using Accessory Power Exhaust 579F180-300Altitude COMPENSATION* Ð 580D090-150 EVAPORATOR-FAN Motor Efficiency580D036 EVAPORATOR-FAN Motor PerformanceMaximum Unit EVAPORATOR-FAN Acceptable Continuous Operating AMP Draw BHPRLA LRA FLA MCA MOCP² Electrical Data Ð 580D036-150Electrical Data Ð 579F180-300 NEC Ð National Electrical Code Typical Piping and Wiring Ð 580D036-150Vertical Discharge Ducting Horizontal Discharge Ducting579F180 shown Typical Piping and Wiring Ð 579F180-300Typical Wiring Schematic Ð 580D036-150 Typical Wiring Schematic 579F240-300, 460-v shown IFC AHAPRI IDMOperating Sequence ControlsCooling, Units With Parablade Economizer 580D036-072 Controls580D036-150 Application DataApplication Data Part 1 Ð General Guide Specifications Ð 580D036-150Guide Specifications Ð 580D036-150 Guide Specifications Ð 580D036-150 Guide Specifications Ð 579F180-300 Guide Specifications Ð 579F180-300 Copyright 1998 Bryant Heating & Cooling Systems