BASE UNIT DIMENSIONS Ð 580D090-150
UNIT |
|
|
| CORNER WEIGHT* |
|
|
|
|
|
|
|
|
|
| DIMENSIONS |
|
|
|
|
| CONNECTION SIZES | |||||||||||
A |
| B |
|
| C |
| D |
|
| ``H'' |
|
| ``J'' |
|
|
| ``K'' |
| ``L'' |
|
| A | 13¤8 | Dia [35] Field Power Supply Hole | ||||||||
580D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B | 21¤2 | Dia [64] Power Supply Knockout |
| lb | kg | lb | kg | lb | kg | lb |
| kg | mm | mm |
|
| mm | mm |
| C | 13¤4 | Dia [44] Charging Port Hole | |||||||||||||
090 | 189 |
| 86 | 161 |
| 73 | 239 |
| 109 | 280 |
| 127 | 378 | 1050 | 856 | 2- 27¤16 | 672 |
| D | 7¤8 | Dia [22] Field Control Wiring Hole | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E | 3¤4 Ð14 NPT Condensate Drain | |
102 | 191 |
| 87 | 163 |
| 74 | 242 |
| 110 | 284 |
| 129 | 1013 | 1050 | 856 | 2- 27¤16 | 672 | |||||||||||||||
|
|
|
|
| F | 1¤2 Ð14 NPT Gas Connection 090 125 & 102 125 | ||||||||||||||||||||||||||
120 | 225 |
| 102 | 192 |
| 87 | 285 |
| 129 | 333 |
| 151 | 7 | ¤8 | 759 | 5 | ¤16 | 1253 |
| 3 | ¤8 |
| 924 | 7 | 875 |
|
| 3¤4 Ð14 NPT Gas Connection All Others | ||||
|
|
|
|
|
|
|
|
|
| G | 2 Dia [51] Power Supply Knockout | |||||||||||||||||||||
150 | 228 |
| 103 | 195 |
| 88 | 289 |
| 131 | 338 |
| 153 | 378 | 1253 |
|
| 924 |
| 875 |
| ||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||
*Weights are for units only (aluminum plate ®ns) and do not include options or crating. |
|
|
|
| NOTES: |
| ] are in millimeters. | |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1. | Dimensions in [ | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2. | Center of gravity. |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3. | Direction of air¯ow. |
|
4. On vertical discharge units, ductwork to be attached to accessory roof curb only. For horizontal discharge units
5. Minimum clearance (local codes or jurisdiction may prevail):
a. Between unit (¯ue side) and combustible surfaces, 48 inches.
b. Bottom of unit to combustible surfaces (when not using curb) 1 inch. Bottom of base rail to combustible surfaces (when not using curb) 0 inches.
c. Condenser coil, for proper air¯ow, 36 in. one side, 12 in. the other. The side getting the greater clearance is optional.
d. Overhead, 60 in. to assure proper condenser fan operation.
e. Between units, control box side, 42 in. per NEC (National Electrical Code). f. Between unit and ungrounded surfaces, control box side, 36 in. per NEC. g. Between unit and block or concrete walls and other grounded surfaces, con-
trol box side, 42 in. per NEC.
h. Horizontal supply and return end, 0 inches.
6. With the exception of the clearance for the condenser coil and combustion side as stated in Notes 5a, b, and c, a removable fence or barricade requires no clearance.
7. Units may be installed on combustible ¯oors made from wood or Class A, B, or C roof covering material if set on base rail.
8. The vertical center of gravity is 1
BOTTOM POWER CHART, THESE HOLES
REQUIRED FOR USE WITH ACCESSORY
PACKAGES Ð CRBTMPWR001A00 ( 1¤2 , 3¤4 )
OR CRBTMPWR002A00 (1¤2 , 11¤4 )
THREADED | WIRE SIZE | REQUIRED HOLE | ||
CONDUIT SIZE | SIZES (MAX) | |||
| ||||
|
|
|
| |
1¤2 | 24 V | 7¤8 | [22.2] | |
3¤4 | Power² | 1 1¤8 | [28.4] | |
11¤4 | Power² | 1 3¤4 | [44.4] |
²Select either 3¤4 or 11¤4 for power, depending on wire size.
18