OPTIONS AND ACCESSORIES (cont)

LIQUID PROPANE (LP) CONVERSION KITS

BRYANT COMMERCIAL

 

 

 

PROGRAMMABLE THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036-072 SHOWN

The LP conversion kit allows the unit to utilize a liquid propane fuel supply in areas where natural gas is unavailable, and per- mits the unit to be converted from natural gas to LP gas use. The kit contains the ori®ces required for LP operation.

Designed speci®cally for use with Bryant commercial sys- tems, this Bryant programmable thermostat features LED occupied/unoccupied displays and setback mode which can override continuous fan operation.

TIME GUARD II CONTROL

Time Guard II control automatically prevents compressor from restarting for at least 5 minutes after a shutdown. Accessory prevents short cycling of compressor if thermostat is changed rapidly. Time Guard II control mounts in the control compart- ment of unit.

DURABLADE ECONOMIZER

(SIZES 036-150)

PARABLADE ECONOMIZER

(SIZES 036-150)

Exclusive Durablade economizer damper design saves energy while providing economical and reliable cooling. A sliding plate on the face of the economizer controls the amount of outdoor air entering the system. Closed, it provides a leakproof seal which prevents ambient air from seeping in or conditioned air from seeping out. It can be ad- justed easily for 100% outdoor air or any proportions of mixed air. Like the base unit, the economizer is converted easily for horizontal discharge applications.

The unique design of the Parablade economizer saves energy while providing economical and reliable cooling. The design uses a parallel- opposed blade damper. The economizer also has built-in spring return for reliable close-on-power-loss. The Parablade design incorporates standard enthalpy controls and up to 45% barometric relief capability for additional ¯exibility in high outdoor air¯ow applications.

15

Image 15
Contents 580D036-072 579F180,216 580D090-150 579F240,300 FEATURES/BENEFITSPage Table of Contents 580D036-150 Models only Model Number NomenclatureModel Number Nomenclature 579F180-300 Models only ARI* Capacity Ratings Rise Efficiency ARI* Capacity RatingsHeating Capacities and Efficiencies Ð 580D036-150 Heating Capacities and Efficiencies Ð 579F180-300Unit Size 580D Physical Data Ð 580D036-072Unit Size 580D Medium LOW/MEDIUM High Heat Physical Data Ð 580D036-072Pulley Center Line Distance Std Physical Data Ð 580D090-150090 102 120 150 Nominal Capacity tons Quantity...Diameter Motor Hp...RpmUnit Size 580D LOW/MEDIUM High Heat Hihg Heat Medium Heat Physical Data Ð 580D090-150Unit Size 579F Physical Data Ð 579F180-300Physical Data Ð 579F180-300 Unit Size 579FLOW/HIGH Heat Head Pressure Control Speed Control 180,216 Options and AccessoriesOption ACCESSORY² Head Pressure ControlSizes Options and AccessoriesTime Guard II Control Durablade EconomizerThermostat Power Exhaust 180-300 Shown Accusensor SensorAccusensor Control OnlyUnit Base Unit Dimensions Ð 580D036-072Unit Corner Weight Dimensions Base Unit Dimensions Ð 580D090-150486 220 636 288 Base Unit Dimensions Ð 579F180,216Dimension Base Unit Dimensions Ð 579F240,300Roof Curb Ð 580D036-072 Accessory DimensionsRoof Curb Ð 580D090-150 Accessory Dimensions579F Dimensions degrees and inchesPKG. NO. REF Curb Description Height Unit DEGPre-Assembled, High Static Horizontal Supply/Return Adapter Installation 579F180-300Power Exhaust 579F180-300 Accessory Curb Description Package no HeightII Select Unit Based on Required Cooling Capacity Selection Procedure with 579F180 exampleSHC Performance Data Cooling CapacitiesCooling Capacities Performance DataPerformance Data Cooling Capacities 580D120 10 Tons580D150 121¤2 Tons 5400/0.06 6000/0.07 7200/0.08 9000/0.09 579F180 15 Tons Temp F Air Entering Evaporator Ð Cfm/BF4500/0.08 5250/0.10 6000/0.11 6750/0.12 7500/0.14 Condenser 579F216 18 Tons579F240 20 Tons Temp F Air Entering Evaporator Ð Cfm/BF 579F300 25 Tons7000/0.03 8750/0.05 10,000/0.07 11,250/0.09 580D036 3 Tons Ð Alternate Motor Belt Drive FAN Performance Ð 580D036-150 Vertical Discharge Units580D036 3 Tons Ð Standard Motor Direct Drive Fiop580D048 4 Tons Ð Alternate Motor Belt Drive 580D048 4 Tons Ð Standard Motor Direct Drive580D060 5 Tons Ð Alternate Motor Belt Drive 580D060 5 Tons Ð Standard Motor Direct Drive1562 580D072 6 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 1800 26003100 580D090 71¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2250 2550904 2300 3400 580D102 81¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2550 891 2188 3300985 580D120 10 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3000 43005200 580D150 121¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3750 5100FAN Performance Ð 580D036-150 Horizontal Discharge Units 352 788 410 887 546 928 615 968 683 1400 640 284 705 1989 1466 2171 Bhp Brake Horsepower Input to FanRpm Bhp Watts 1200 569 189 641 299 761 357 859 483 901 546 943 609 1300 604 231 6731331 1986 1400 2227 1461 Medium Speed High Speed 208 230, 460, 575 230,460, 5751392 1365 2038 14261603 15361514 1496 2240 1529895 997 3055 1040 3333 Bhp Brake Horsepower Input to Fan894 882812 1062 3676 1102 3860 Bhp Brake Horsepower Input to FanRpm Bhp Watts 2550 669 627 867 692 1056 754 7831019 9621008 9731131 Bhp Watts 37501166 1178FAN Performance Ð 579F180-300 Units Performance Data FAN Performance Ð 579F180-300 Units 9500 10,000 Bhp Brake Horsepower Input to Fan579F240 20 Tons Air¯ow External Static Pressure in. wg Rpm Bhp Watts 60003507 10,500 11,000 11,250 Bhp Brake Horsepower Input to Fan579F300 25 Tons Air¯ow Rpm Bhp Watts 500Unit Minimum CFM Maximum CFM Sound Power Total UnitSound Weighted Octave Bands Unit Rating AIR Quantity LimitsUnit Motor Pulley Turns Open ACCESSORY/FIOP Static PRESSURE* in. wg − 580D090-150ACCESSORY/FIOP Static PRESSURE* in. wg − 579F180-300 Component CFMInput Altitude COMPENSATION* ÐBtuh Nominal Nominal InputAltitude Derating FACTOR* Ð ALL Units Fan Performance Using Accessory Power Exhaust 579F180-300Altitude COMPENSATION* Ð 580D090-150 EVAPORATOR-FAN Motor Efficiency580D036 EVAPORATOR-FAN Motor PerformanceMaximum Unit EVAPORATOR-FAN Acceptable Continuous Operating AMP Draw BHPRLA LRA FLA MCA MOCP² Electrical Data Ð 580D036-150Electrical Data Ð 579F180-300 NEC Ð National Electrical Code Typical Piping and Wiring Ð 580D036-150Vertical Discharge Ducting Horizontal Discharge Ducting579F180 shown Typical Piping and Wiring Ð 579F180-300Typical Wiring Schematic Ð 580D036-150 Typical Wiring Schematic 579F240-300, 460-v shown IFC AHAPRI IDMOperating Sequence ControlsCooling, Units With Parablade Economizer 580D036-072 Controls580D036-150 Application DataApplication Data Part 1 Ð General Guide Specifications Ð 580D036-150Guide Specifications Ð 580D036-150 Guide Specifications Ð 580D036-150 Guide Specifications Ð 579F180-300 Guide Specifications Ð 579F180-300 Copyright 1998 Bryant Heating & Cooling Systems