PROVEN COMPRESSOR RELIABILITY Ð Design techniques feature computer programmed balance between compressor, condenser, and evaporator. Hermetic (036-150 units) and semi- hermetic (180-300 units) compressors with suction and discharge service valves are equipped with compressor over- current and overtemperature protection to ensure dependability. Crankcase heaters (180-300 units) prevent refrigerant dilution of oil during off cycles and ensure proper lubrication at start-up to prolong compressor life. Crankcase heaters are not neces- sary on 036-150 units due to high-side crankcase design (sizes 072,150) and low refrigerant charge levels (sizes 036-150).

The 579F180 unit (with factory-supplied unloading) is equipped with a thermostatic expansion valve to precisely adjust refriger- ant ¯ow during Stage 1 (unloaded) operation. All other 579F/ 580D units have the exclusive Acutrol™ metering device which precisely controls refrigerant ¯ow, preventing slugging and ¯ood-back, while maintaining optimum unit performance.

Additional unloaders are not recommended on the 579F180- 300 units.

INTEGRATED ECONOMIZERS AND OUTDOOR AIR Ð Optional economizers and manual outdoor-air dampers intro- duce outdoor air which mixes with the conditioned air, improving indoor air quality and often reducing energy consumption.

During a ®rst stage call for cooling, if the outdoor-air tempera- ture is below the control changeover set point, the discharge-air sensor modulates the economizer outdoor-air damper open to achieve the changeover set point. When second-stage cooling is called for, the compressor is energized in addition to the economizer. If the outdoor-air temperature is above the change- over set point, the ®rst stage of compression is activated and the economizer stays at vent position. Economizer operation is controlled by Accusensor™ I dry-bulb thermostat that senses outdoor-air temperature. Accessory upgrade kits include Accu- sensor II solid-state enthalpy control (sizes 036-150) and Accu- sensor III enthalpy sensor.

The Durablade economizer (option or accessory) on the 580D036-150 units has a reliable sliding plate damper which is easily adjusted for 100% outdoor air, 100% return air, or any proportions of mixed air.

The 580D036-150 units can also utilize the optional Parablade economizer. This economizer incorporates a parallel-opposed

blade design with standard enthalpy controls. In addition, the Parablade economizer has a spring return built into the damper motor to provide reliable close-on-power-loss. The Parablade economizer comes equipped with up to 45% barometric relief capability for high outdoor air¯ow applications.

For units without economizer, year-round ventilation is en- hanced by a manual outdoor-air damper (ordered as standard on 579F180-300; ordered as an accessory or an option on 580D036-150 units). The damper can be preset to admit up to 25% outdoor air (sizes 180-300) or 50% outdoor air (sizes 036-150).

In addition, the barometric relief damper or power exhaust accessory can be utilized to help maintain proper building pressure.

INDOOR-AIR QUALITY Ð Sloped condensate pans minimize biological growth in rooftop units in accordance with ASHRAE (American Society of Heating, Refrigeration, and Air Condition- ing Engineers) Standard 62-89. Two-inch ®lters with optional dirty ®lter indicator switch provide for greater particle reduction in the return air. The face-split evaporator coils improve the de- humidi®cation capability of standard units, and standard en- thalpy controls provided with the optional or accessory (sizes 036-150) economizers maximize building humidity control.

TABLE OF CONTENTS

 

Page

Features/Bene®ts

. 1-3

Model Number Nomenclature

. 4,5

ARI Capacity Ratings

. 6,7

Physical Data

. 8-13

Options and Accessories

14-16

Base Unit Dimensions

17-20

Accessory Dimensions

21-24

Selection Procedure

. 25

Performance Data

26-55

Electrical Data

56,57

Typical Piping and Wiring

58,59

Typical Wiring Schematics

60-62

Controls

63,64

Application Data

65,66

Guide Speci®cations

67-72

3

Image 3
Contents 580D036-072 579F180,216 580D090-150 579F240,300 FEATURES/BENEFITSPage Table of Contents 580D036-150 Models only Model Number NomenclatureModel Number Nomenclature 579F180-300 Models only ARI* Capacity Ratings Rise Efficiency ARI* Capacity RatingsHeating Capacities and Efficiencies Ð 580D036-150 Heating Capacities and Efficiencies Ð 579F180-300Unit Size 580D Physical Data Ð 580D036-072Unit Size 580D Medium LOW/MEDIUM High Heat Physical Data Ð 580D036-072Pulley Center Line Distance Std Physical Data Ð 580D090-150090 102 120 150 Nominal Capacity tons Quantity...Diameter Motor Hp...RpmUnit Size 580D LOW/MEDIUM High Heat Hihg Heat Medium Heat Physical Data Ð 580D090-150Unit Size 579F Physical Data Ð 579F180-300Physical Data Ð 579F180-300 Unit Size 579FLOW/HIGH Heat Head Pressure Control Speed Control 180,216 Options and AccessoriesOption ACCESSORY² Head Pressure ControlSizes Options and AccessoriesTime Guard II Control Durablade EconomizerThermostat Power Exhaust 180-300 Shown Accusensor SensorAccusensor Control OnlyUnit Base Unit Dimensions Ð 580D036-072Unit Corner Weight Dimensions Base Unit Dimensions Ð 580D090-150486 220 636 288 Base Unit Dimensions Ð 579F180,216Dimension Base Unit Dimensions Ð 579F240,300Roof Curb Ð 580D036-072 Accessory DimensionsRoof Curb Ð 580D090-150 Accessory Dimensions579F Dimensions degrees and inchesPKG. NO. REF Curb Description Height Unit DEGPre-Assembled, High Static Horizontal Supply/Return Adapter Installation 579F180-300Power Exhaust 579F180-300 Accessory Curb Description Package no HeightII Select Unit Based on Required Cooling Capacity Selection Procedure with 579F180 exampleSHC Performance Data Cooling CapacitiesCooling Capacities Performance DataPerformance Data Cooling Capacities 580D120 10 Tons580D150 121¤2 Tons 5400/0.06 6000/0.07 7200/0.08 9000/0.09 579F180 15 Tons Temp F Air Entering Evaporator Ð Cfm/BF4500/0.08 5250/0.10 6000/0.11 6750/0.12 7500/0.14 Condenser 579F216 18 Tons579F240 20 Tons Temp F Air Entering Evaporator Ð Cfm/BF 579F300 25 Tons7000/0.03 8750/0.05 10,000/0.07 11,250/0.09 580D036 3 Tons Ð Alternate Motor Belt Drive FAN Performance Ð 580D036-150 Vertical Discharge Units580D036 3 Tons Ð Standard Motor Direct Drive Fiop580D048 4 Tons Ð Alternate Motor Belt Drive 580D048 4 Tons Ð Standard Motor Direct Drive580D060 5 Tons Ð Alternate Motor Belt Drive 580D060 5 Tons Ð Standard Motor Direct Drive1562 580D072 6 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 1800 26003100 580D090 71¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2250 2550904 2300 3400 580D102 81¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 2550 891 2188 3300985 580D120 10 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3000 43005200 580D150 121¤2 Tons Air¯ow External Static Pressure in. wgRpm Bhp Watts 3750 5100FAN Performance Ð 580D036-150 Horizontal Discharge Units 352 788 410 887 546 928 615 968 683 1400 640 284 705 1989 1466 2171 Bhp Brake Horsepower Input to FanRpm Bhp Watts 1200 569 189 641 299 761 357 859 483 901 546 943 609 1300 604 231 6731331 1986 1400 2227 1461 Medium Speed High Speed 208 230, 460, 575 230,460, 5751392 1365 2038 14261603 15361514 1496 2240 1529895 997 3055 1040 3333 Bhp Brake Horsepower Input to Fan894 882812 1062 3676 1102 3860 Bhp Brake Horsepower Input to FanRpm Bhp Watts 2550 669 627 867 692 1056 754 7831019 9621008 9731131 Bhp Watts 37501166 1178FAN Performance Ð 579F180-300 Units Performance Data FAN Performance Ð 579F180-300 Units 9500 10,000 Bhp Brake Horsepower Input to Fan579F240 20 Tons Air¯ow External Static Pressure in. wg Rpm Bhp Watts 60003507 10,500 11,000 11,250 Bhp Brake Horsepower Input to Fan579F300 25 Tons Air¯ow Rpm Bhp Watts 500Unit Minimum CFM Maximum CFM Sound Power Total UnitSound Weighted Octave Bands Unit Rating AIR Quantity LimitsUnit Motor Pulley Turns Open ACCESSORY/FIOP Static PRESSURE* in. wg − 580D090-150ACCESSORY/FIOP Static PRESSURE* in. wg − 579F180-300 Component CFMInput Altitude COMPENSATION* ÐBtuh Nominal Nominal InputAltitude Derating FACTOR* Ð ALL Units Fan Performance Using Accessory Power Exhaust 579F180-300Altitude COMPENSATION* Ð 580D090-150 EVAPORATOR-FAN Motor Efficiency580D036 EVAPORATOR-FAN Motor PerformanceMaximum Unit EVAPORATOR-FAN Acceptable Continuous Operating AMP Draw BHPRLA LRA FLA MCA MOCP² Electrical Data Ð 580D036-150Electrical Data Ð 579F180-300 NEC Ð National Electrical Code Typical Piping and Wiring Ð 580D036-150Vertical Discharge Ducting Horizontal Discharge Ducting579F180 shown Typical Piping and Wiring Ð 579F180-300Typical Wiring Schematic Ð 580D036-150 Typical Wiring Schematic 579F240-300, 460-v shown IFC AHAPRI IDMOperating Sequence ControlsCooling, Units With Parablade Economizer 580D036-072 Controls580D036-150 Application DataApplication Data Part 1 Ð General Guide Specifications Ð 580D036-150Guide Specifications Ð 580D036-150 Guide Specifications Ð 580D036-150 Guide Specifications Ð 579F180-300 Guide Specifications Ð 579F180-300 Copyright 1998 Bryant Heating & Cooling Systems