Heat & Glo LifeStyle EXCLAIM-36H-C owner manual fireplace burns the wood too fast. What can I do?

Page 34

The fireplace burns the wood too fast. What can I do?

 

Diagnostic Questions

 

Possible Causes of Condition

 

Solutions

 

 

 

 

Do you have glass doors?

Need to slow air intake

 

Add glass doors.

 

 

 

 

 

 

 

What is the condition of the

Extremely dry wood

 

Mix in less seasoned wood after fire established.

 

wood?

 

 

 

 

 

 

 

 

 

 

I smell smoke in the house during operation. What’s causing that?

 

Diagnostic Questions

 

Possible Causes of Condition

 

Solutions

 

 

 

 

Does the fire start and burn

No:

 

 

 

well?

• Damper not fully open

 

Open damper; check and clean chimney if needed; use adequate

 

 

 

 

 

Chimney obstruction

 

kindling and fuel; open glass doors or open window, check for

 

 

 

need for balanced air make-up.

 

 

Not enough kindling and/or fuel to establish

 

 

 

 

 

 

 

 

draft

 

 

 

 

Inadequate combustion air

 

 

 

 

Yes:

 

 

 

 

Fire too close to front

 

Build fire farther back. Do not use exhaust fans during startup

 

 

Competition with exhaust devices

 

and/or check for need for balanced air make-up system.

 

 

 

 

 

 

 

 

 

 

I smell smoke in the house after we’ve had a fire in the fireplace. What is the cause/what can we do?

 

Diagnostic Questions

 

Possible Causes of Condition

 

Solutions

 

 

 

 

Is the damper closed?

• No: Downdraft or negative pressure

 

Close the damper at end of burn.

 

 

Yes: Negative pressure from exhaust fans

 

Check for need for glass doors. Check for need for balanced air

 

 

 

and/or house stack effect.

 

make-up system or raising chimney.

 

 

 

 

 

 

Is the chimney clean?

• No: Creosote odor

 

Have chimney cleaned.

 

 

Yes: Damper closed too early

 

Wait until fire completely out before closing damper.

 

 

 

 

 

 

34

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

Image 34
Contents EXCLAIM-36H-C EXCLAIM-36T-C Fire RiskGrate Listing Label Information/LocationNumber Table of Contents Appliance Certification Listing and Code ApprovalsNot intended for use as a primary heat source Negative Pressure Design and Installation ConsiderationsGetting Started Asphyxiation RiskMarginal Location Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationClearances Failure to comply may cause fireSidewalls/Surrounds Frame the FireplaceConstruct the Chase Chimney RequirementsFire Risk Sharp Edges Asphyxiation Risk Installation of FireplaceInstall the Outside Air Kit Risk of Smoke SpillageFt min. from top of uppermost chimney section to air inlet Place the Protective Metal Hearth Strips Secure the FireplacePosition the Fireplace Level the FireplaceChimney Assembly Height of Chimney Components Using Offsets/Returns ¨ TableInstall the Ceiling Firestops Assemble the Chimney SectionsDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney Complete the Enclosure Chimney TerminationInstall the Chimney Air Kit required in Canada Install the Termination CapChase Top Installing an ST475 Square Termination Cap Gas Log/Lighter Provisions AccessoriesGas Code, Ansi Z223.1 Finishing Hearth ExtensionRaised Hearth Extension Glass Doors Finishing MaterialMantel Combustible MaterialOperating Instructions General InformationFlue Damper Outside AirClear Space Near the Fireplace FirescreenFirewood GrateWood Fuel MoistureStarting a Fire Troubleshooting Understanding Vent ProblemsSolutions Diagnostics and Problem SolvingDiagnostic Questions Can’t get a good fire going. What am I doing wrong?fireplace burns the wood too fast. What can I do? Disposal of Ashes Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Firebox RefractoryClean Maintenance Task ListWhen cleaning glass door Chimney FireFireplace Dimensions Reference MaterialsFireplace Components Catalog # DescriptionChimney Components Catalog #330 mm 51 mm 14-3/4 375 mm This page intentionally left blank TR442 TR442 / 444 TV Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 XMinimum Base Dimensions 26.5 X 28 with 34 X 34 with 20 xService Parts EXCLAIM-36-C Series Service PartsDescription of Part EXCLAIM-36T-C EXCLAIM-36H-C Qty.req This page intentionally left blank Warranty For Heat & GLO Fireplaces Limited WarrantyContact Information Do Discardnot