Step 2

Framing the

Fireplace

CAUTION

Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall coverings and fireplace facing material. The diagram below shows framing reference dimensions.

MEASURE FIREPLACE DIMENSIONS, AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS, BEFORE FRAMING CONSTRUCTION BEGINS.

WALL

STUD

14 cm

D* E*

B *

C

Framing should be constructed of 2 X 4 lumber or heavier.

A

8 cm

NON-COMBUSTIBLE ZONE

* Note: Dimension B taken from fin-

 

ished hearth frame. Dimensions D

IS DEFINED BY 8 CM ABOVE

 

THE ELBOW FOR THE ENTIRE

and E taken from bottom of unit.

WIDTH AND DEPTH (BEHIND

 

 

 

 

THE FRONT HEADER) OF

 

 

 

 

THE FIREBOX.

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

D

E

 

 

107 cm

102 cm

56 cm

68,3 cm

106 cm

 

 

 

 

 

 

 

 

Figure 4. Framing Dimensions

Heat & Glo • 6000TRS-CE2049-900 Rev. Q • 2/11

11

Image 11
Contents What to do if you smell gas ModelSafety and Warning Information Maintaining and Servicing Installing the FireplaceService Parts Log Set Assembly6000TRS-CE Service Parts List6000TRS-CE Valve AssemblyAppliance Certification Installation RegulationsANY Such Action MAY Possibly Cause a Fire Hazard Location Centimeters Clearance Requirements StepLocating FireplaceFraming should be constructed of 2 X 4 lumber or heavier Step Framing FireplaceIdentifying Flue Components Step Installing Flue SystemFlue System Approvals DVP4 DVP6 DVP12 Straight UP Flue with ONE 1 90o Elbow Flue with TWO 2 90 Elbows Flue with TWO 2 90 Elbows Flue with Three 3 90 Elbows + H Venting Out the Top Flue Installing Flue ComponentsVenting Out the Rear Flue On the TOP of the heater Install Support BracketsInstalling Support Brackets Install FirestopsFlue Pipe & Firestop Flue Termination For Horizontal Terminations using the DVP-TRAPBe Positioned SO That the Arrow is Pointing UP DVP Termination Cap Outside of the building Alcove Applications Standing Pilot Ignition System Step Positioning Leveling, Securing FireplaceStep Gas Supply Line Step Gas Pressure Requirements Optional AccessoriesFinishing Fractory Installing the TrimInstalling the Ceramic Re LOG Placement Heat & Glo 6000TRS-CE 2049-900 Rev. Q 2/11 Placing the Ember Material Glass AssemblyDouble-check for gas leaks Review safety warnings and cautionsDouble-check for faulty components Step Before Lighting FireplaceStep Lighting Fireplace After the Installation Maintaining Servicing Your Fireplace Make Sure the Flames Standing Pilot Troubleshooting With the pilot lit, and the ON/OFF switch Placed in this Opening Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions