Heat & Glo LifeStyle 6000TRS-CE manual Flue with Three 3 90 Elbows

Page 18

 

FLUE WITH THREE (3) 90° ELBOWS

V

H

H + H1

MIN. 30.5 cm

MAX. 61.0 cm

MIN. 61.0 cm

MAX. 1.22 m

MIN. 91.4 cm

MAX. 1.86 m

MIN. 1.22 m

MAX.

2.48 m

H = MAX. 2.48 m

MAX.

4.9 m

MAX. 1.22 m MAX. 2.48 m MAX. 3.6 m MAX. 4.9 m

NOTE: V + V1 + H + H1 = MAX. 10.97 m

V1

V

H1

 

FLUE WITH THREE (3) 90° ELBOWS

V

H

H + H1 + H2

MIN. 30.5 cm MIN. 61.0 cm MIN. 91.4 cm MIN. 1.22 m MAX. 6.1 m

MAX. 61.0 cm MAX. 61.0 cm MAX. 1.22 m MAX. 1.86 m MAX. 1.86 m

MAX. 1.22 m MAX. 2.48 m MAX. 3.6 m MAX. 4.9 m MAX. 4.9 m

V

H2

H1

Figure 13. Flue with three 90° elbows

18

Heat & Glo • 6000TRS-CE2049-900 Rev. Q • 2/11

Image 18
Contents Model What to do if you smell gasSafety and Warning Information Installing the Fireplace Maintaining and ServicingLog Set Assembly Service PartsService Parts List 6000TRS-CEValve Assembly 6000TRS-CEInstallation Regulations Appliance CertificationANY Such Action MAY Possibly Cause a Fire Hazard Location Centimeters Fireplace StepLocating Clearance RequirementsStep Framing Fireplace Framing should be constructed of 2 X 4 lumber or heavierStep Installing Flue System Flue System ApprovalsIdentifying Flue Components DVP4 DVP6 DVP12 Straight UP Flue with ONE 1 90o Elbow Flue with TWO 2 90 Elbows Flue with TWO 2 90 Elbows Flue with Three 3 90 Elbows + H Installing Flue Components Venting Out the Rear FlueVenting Out the Top Flue Install Support Brackets On the TOP of the heaterInstall Firestops Installing Support BracketsFlue Pipe & Firestop For Horizontal Terminations using the DVP-TRAP Flue TerminationBe Positioned SO That the Arrow is Pointing UP DVP Termination Cap Outside of the building Alcove Applications Step Positioning Leveling, Securing Fireplace Standing Pilot Ignition SystemStep Gas Supply Line Optional Accessories Step Gas Pressure RequirementsFinishing Installing the Trim Installing the Ceramic ReFractory LOG Placement Heat & Glo 6000TRS-CE 2049-900 Rev. Q 2/11 Glass Assembly Placing the Ember MaterialStep Before Lighting Fireplace Review safety warnings and cautionsDouble-check for faulty components Double-check for gas leaksStep Lighting Fireplace After the Installation Maintaining Servicing Your Fireplace Make Sure the Flames Standing Pilot Troubleshooting With the pilot lit, and the ON/OFF switch Placed in this Opening Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions