Heat & Glo LifeStyle 6000TRS-CE manual Step Positioning Leveling, Securing Fireplace

Page 29

Step 4

Positioning,

Leveling, and

Securing the

Fireplace

1.Place the fireplace into position.

2.Level the fireplace from side to side and from front to back.

3.Shim the fireplace with non-combustible ma- terial, such as sheet metal, as necessary.

4.Secure the fireplace to the framing by nailing or screwing.

Step 5

The Gas Control

System

The diagram below shows how to properly position, level, and secure the fireplace.

NAILING TABS

(BOTH SIDES)

Figure 26. Proper Positioning, Leveling, and Securing of a

Fireplace

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

!WARNING: 230 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

STANDING PILOT

Figure 27. Gas Control System

Heat & Glo • 6000TRS-CE2049-900 Rev. Q • 2/11

29

Image 29
Contents What to do if you smell gas ModelSafety and Warning Information Maintaining and Servicing Installing the FireplaceService Parts Log Set Assembly6000TRS-CE Service Parts List6000TRS-CE Valve AssemblyAppliance Certification Installation RegulationsANY Such Action MAY Possibly Cause a Fire Hazard Location Centimeters Locating StepFireplace Clearance RequirementsFraming should be constructed of 2 X 4 lumber or heavier Step Framing FireplaceIdentifying Flue Components Step Installing Flue SystemFlue System Approvals DVP4 DVP6 DVP12 Straight UP Flue with ONE 1 90o Elbow Flue with TWO 2 90 Elbows Flue with TWO 2 90 Elbows Flue with Three 3 90 Elbows + H Venting Out the Top Flue Installing Flue ComponentsVenting Out the Rear Flue On the TOP of the heater Install Support BracketsInstalling Support Brackets Install FirestopsFlue Pipe & Firestop Flue Termination For Horizontal Terminations using the DVP-TRAPBe Positioned SO That the Arrow is Pointing UP DVP Termination Cap Outside of the building Alcove Applications Standing Pilot Ignition System Step Positioning Leveling, Securing FireplaceStep Gas Supply Line Step Gas Pressure Requirements Optional AccessoriesFinishing Fractory Installing the TrimInstalling the Ceramic Re LOG Placement Heat & Glo 6000TRS-CE 2049-900 Rev. Q 2/11 Placing the Ember Material Glass AssemblyDouble-check for faulty components Review safety warnings and cautionsStep Before Lighting Fireplace Double-check for gas leaksStep Lighting Fireplace After the Installation Maintaining Servicing Your Fireplace Make Sure the Flames Standing Pilot Troubleshooting With the pilot lit, and the ON/OFF switch Placed in this Opening Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions