Heat & Glo LifeStyle 6000TRS-CE manual Step Before Lighting Fireplace, Double-check for gas leaks

Page 37

Step 11

Before Lighting

the Fireplace

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

• NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Before lighting the fireplace, be sure to do the following:

Review safety warnings and cautions

Read the Safety and Warning Information section at the beginning of this Installers Guide.

Double-check for gas leaks

Before lighting the fireplace, double-check the unit for possible gas leaks.

Double-check flue terminations and front grilles for obstructions.

Before lighting the fireplace, double-check the unit for possible obstructions that could be blocking the flue terminations or the front grilles.

Double-check for faulty components

Any component that is found to be faulty MUST BE replaced with an approved component. Tampering with the fireplace components is DANGEROUS and voids all warranties.

A small amount of air will be in the gas supply lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and will operate normally.

Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines, unless the gas valve has been turned to the OFF position, in which case the air would have to be purged.

NOTE: The fireplace should be run for 3 to 4 hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the fireplace for an additional 8 hours. This will help to cure the products used in the paint and logs.

Heat & Glo • 6000TRS-CE2049-900 Rev. Q • 2/11

37

Image 37
Contents What to do if you smell gas ModelSafety and Warning Information Maintaining and Servicing Installing the FireplaceService Parts Log Set Assembly6000TRS-CE Service Parts List6000TRS-CE Valve AssemblyAppliance Certification Installation RegulationsANY Such Action MAY Possibly Cause a Fire Hazard Location Centimeters Locating StepFireplace Clearance RequirementsFraming should be constructed of 2 X 4 lumber or heavier Step Framing FireplaceFlue System Approvals Step Installing Flue SystemIdentifying Flue Components DVP4 DVP6 DVP12 Straight UP Flue with ONE 1 90o Elbow Flue with TWO 2 90 Elbows Flue with TWO 2 90 Elbows Flue with Three 3 90 Elbows + H Venting Out the Rear Flue Installing Flue ComponentsVenting Out the Top Flue On the TOP of the heater Install Support BracketsInstalling Support Brackets Install FirestopsFlue Pipe & Firestop Flue Termination For Horizontal Terminations using the DVP-TRAPBe Positioned SO That the Arrow is Pointing UP DVP Termination Cap Outside of the building Alcove Applications Standing Pilot Ignition System Step Positioning Leveling, Securing FireplaceStep Gas Supply Line Step Gas Pressure Requirements Optional AccessoriesFinishing Installing the Ceramic Re Installing the TrimFractory LOG Placement Heat & Glo 6000TRS-CE 2049-900 Rev. Q 2/11 Placing the Ember Material Glass AssemblyDouble-check for faulty components Review safety warnings and cautionsStep Before Lighting Fireplace Double-check for gas leaksStep Lighting Fireplace After the Installation Maintaining Servicing Your Fireplace Make Sure the Flames Standing Pilot Troubleshooting With the pilot lit, and the ON/OFF switch Placed in this Opening Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions