Vermont Casting BHDR36 installation instructions Lighting and Operating Instructions

Page 30

LIGHTING AND OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the fireplace area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace.

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to off position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn clockwise

to "OFF". Do not force.

LO

HI

it

N

 

OFF

 

 

 

O

 

F

 

PILOT

T

P

OF

 

 

OLI

 

 

EURO SIT

SIT NOVA

HONEYWELL

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal in manual).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

OR

If knob does not pop up when released, stop and immediately call your service technician or gas

supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to "On" position.

13.For Rn/RP appliances turn the On/Off switch to "On" positin or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

TO TURN OFF GAS TO FIREPLACE

1.

Turn the On/Off switch to Off position or set the

4.

Push in gas control knob slightly

 

thermostat to lowest setting.

 

and turn clockwise

to

2.

Turn off all electric power to the fireplace if service

 

"OFF". Do not force.

 

 

is to be performed.

5.

Close control access panel.

 

3.Open control access panel.

- 30 -

Image 30 Contents
BHDR36 Table of Contents Installation Instructions Locating Your GAS FireplaceFireplace Dimensions Clearance to Combustibles Mantel ChartMantels Framing and FinishingGAS Specifications Final FinishingHearth GAS Line Installation Remote Switch Installation For RN/RPGeneral Venting Information Termination Clearances Rear Wall Installations Rear Venting ApplicationsVertical Sidewall Installations Vertical Sidewall Applications HOW to USE the Vent Graph Vent Sidewall InstallationSidewall Venting Graph Ensure Pipes Are Below Grade Installations Vertical Through Roof ApplicationsVertical Thru Roof Installation Proceed to plumb for additional openings throughCrimped END Venting Components General Information on Assembling Twist Lock Vent Pipes Rear Venting Applications190mm Vertical Sidewall Installations Vertical Sidewall ApplicationsSee page 23 for Venting Requirements for Snorkels NON-COMBUSTIBLE Walls Hole opening must be Below Grade Installations InstallationVertical Through Roof Applications RiseVertical Through the Roof Installation Twist Lock Venting Components Louvre Removal Glass CleaningGeneral Glass Information Glass Frame RemovalInstallation of Logs Flame AdjustmentLava Rock Cleaning the Standing Pilot Control System Flame CharacteristicsMaintenance Inspecting the Venting SystemLighting and Operating Instructions Trouble Shooting the GAS Control System SIT 820 Nova Millivolt Valve Replacement Parts List Replacement Parts Wiring Instructions Optional BAY Window InstallationOptional FAN KIT FK24 Optional Screen KIT Installation Optional Ceramic Refractory InstallationOptional Remote Control