Vermont Casting BHDR36 Mantels, Mantel Chart, Clearance to Combustibles, Framing and Finishing

Page 5

MANTELS

Depending on the width of the mantel it may be installed higher or lower from the top of the louvre opening. See drawing and chart below for proper installation height of your combustible mantel piece. Non-combustible mantels may be installed at any height above the appliance opening.

When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent discolouration.

 

V

 

 

 

W

 

 

 

X

 

 

 

 

WALL

 

A

Y

 

 

 

 

 

 

B

 

 

 

C

 

 

 

Z

 

 

 

D

 

 

 

E

 

 

 

TOP

 

 

 

LOUVRE

 

 

 

OPENING

 

 

 

FRONT GLASS

 

 

 

SIDE VIEW

 

 

 

OPTIONAL

 

 

 

HEARTH

 

 

 

GAS

 

ELECTRICAL

 

KNOCK-OUT

ELECTRICAL CABLE

BOX KNOCK-OUT

 

 

KNOCK-OUT

 

 

 

 

Fig. 3

MANTEL CHART

Ref.

Mantel

Ref. Mantel From

Mantel Leg from

 

Depth

Top Louvre

Fireplace Side

CLEARANCE TO COMBUSTIBLES

 

Back

0 mm/0 inches

 

 

 

 

Side

0 mm/0 inches

 

 

Floor

0 mm/0 inches

 

 

Top

0 mm/0 inches

 

 

 

 

 

 

 

 

 

FRAMING AND FINISHING

1.Choose fireplace location.

2.Place fireplace into position and secure to floor with 1-1/2" screws, or nails. The holes to secure the fireplace to the floor are located just behind the access door grill on the left and right hand side of the fireplace.

3.Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame.

4.Attach fireplace to frame using adjustable frame drywall strips(located behind access door for shipping). Preset depth to suit facing material (adjustable to 1/2" , 5/8" or 3/4" depths). Fig. 4.

5.Screw through slotted holes in drywall strip and then screw into pre-drilled holes on fireplace side. Measure from face of fireplace to face of drywall strip to determine final depth. (Fig. 5 & 6)

C ADJUSTABLE DRYWALL STRIP

A

(NAILING FLANGE)

 

 

B

 

 

 

SCREW

DRYWALL

 

POSITION

DEPTHS

 

A

1/2" / 13mm

 

B

5/8" / 16mm

 

C

3/4" / 19mm

Fig. 4

V

10" (254 mm)

A

12" (305 mm)

10" (254mm)

 

W

8" (203 mm)

B

10" (254 mm)

8" (203mm)

 

 

 

 

 

 

 

 

X

6"

(152 mm)

C

8" (203 mm)

6" (152mm)

 

 

 

 

 

 

 

 

 

Y

4"

(101 mm)

D

6"

(152 mm)

4" (101mm)

 

 

 

 

 

 

 

 

Z

2" ( 51 mm)

E

4"

(101 mm)

2" (51mm)

 

Fig. 5

Adjustable 1/2",5/8"

& 3/4" spacing

Fig. 6

- 5 -

Image 5 Contents
BHDR36 Table of Contents Locating Your GAS Fireplace Installation InstructionsFireplace Dimensions Mantels Mantel ChartClearance to Combustibles Framing and FinishingHearth GAS SpecificationsFinal Finishing Remote Switch Installation For RN/RP GAS Line InstallationGeneral Venting Information Termination Clearances Rear Venting Applications Rear Wall InstallationsVertical Sidewall Installations Vertical Sidewall Applications Sidewall Venting Graph HOW to USE the Vent GraphVent Sidewall Installation Ensure Pipes Are Vertical Through Roof Applications Below Grade InstallationsProceed to plumb for additional openings through Vertical Thru Roof InstallationCrimped END Venting Components Rear Venting Applications General Information on Assembling Twist Lock Vent Pipes190mm Vertical Sidewall Applications Vertical Sidewall InstallationsSee page 23 for Venting Requirements for Snorkels NON-COMBUSTIBLE Walls Hole opening must be Installation Below Grade InstallationsRise Vertical Through Roof ApplicationsVertical Through the Roof Installation Twist Lock Venting Components General Glass Information Glass CleaningLouvre Removal Glass Frame RemovalLava Rock Installation of LogsFlame Adjustment Maintenance Flame CharacteristicsCleaning the Standing Pilot Control System Inspecting the Venting SystemLighting and Operating Instructions Trouble Shooting the GAS Control System SIT 820 Nova Millivolt Valve Replacement Parts List Replacement Parts Optional FAN KIT FK24 Wiring InstructionsOptional BAY Window Installation Optional Remote Control Optional Screen KIT InstallationOptional Ceramic Refractory Installation