FINAL FINISHING
HEARTH
A hearth is not mandatory but it is recommended for aesthetic purposes. We recommend a
Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.
GAS SPECIFICATIONS
|
|
|
| MAX. | MIN. |
|
|
|
| INPUT | INPUT |
MODEL | FUEL | GAS CONTROL | B.T.U.H | B.T.U.H. | |
BHDR36 RN | Natural Gas | Millivolt | Hi/Lo | 18,000 | 12,600 |
BHDR36 RP | Propane Gas | Millivolt | Hi/Lo | 18,000 | 13,500 |
|
|
|
|
|
|
GAS INLET & MANIFOLD PRESSURES
| NATURAL | LP (Propane) |
Input Minimum | 4.5" wc | 11" wc |
Input Maximum | 7" wc | 13" wc |
Manifold Pressure | 3.5" wc | 10" wc |
CERTIFIED TO
ANSI
Vented Gas Fireplace Heaters
Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control which has been under water.
The installation of your Majestic Fireplace must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1 latest edition, or CAN