Vermont Casting 2100 Move the Entire Unit the final few inches into the Cabinet

Page 37

12.Move the Entire Unit the final few inches into the Cabinet.

Move the WinterWarm the final few inches into the cabinet, making sure the surround panels are properly aligned. If you are using the CFM Corporation Flex Connector System, reach up into the flue collar area to grasp the Starter Piece and pull it down into the flue collar. Bend the retaining tabs 90° against the bottom of the flue collar.

13. Install the Latticework Panels.

The two panels are not interchangeable. Each is la- beled with a designating letter cast into the iron next to the tab — “L” for left and “R” for right. The corner cut- outs must be positioned on the back edge. The panels are anchored at the bottom by a single tab that is bolted on. (Fig. 59) At the top, the panels are retained by the overhang of the mantel.

Latticework

Panel

Corner Cut-out

Bolted-on Tab

FP1136

 

Fig. 59 A single tab at the bottom anchors the latticework panel, while the top of the panel is held in place by the mantel overhang.

Lower the panel and seat it on the base so the anchor tab locks behind the rib cast in the base plate. Secure it in place temporarily by holding it or with tape until the mantel is installed.

14. Install the Mantel.

Place the mantel flat side down on the floor. Lift the mantel slightly and slip the drilled and tapped ends of the column capitals under each end of the mantel. Align the two tapped holes in each capital with the two holes in each end of the mantel, and thread in two 3/4” (19mm) hex head cap screws and two washers. Do not tighten these cap screws with a wrench; leave them finger tight. Use care during this assembly process, especially with enamelled parts. Forcing the mantel or capitals into position may cause chipping or cracking.

Install the mantel and capital assembly by raising it into position and tilting it to the rear against the upper shroud flange, with the flange on the shroud in front of the back rib on the mantel. Push against the flange slightly before lowering the front edge of the assembly onto the upper trim piece.

WinterWarm Fireplace Insert or System

15. (Fireplace Systems only) Install the Plinth.

The plinth assembly consists of a pre-assembled plinth center and front, two plinth end caps, two plinth connec- tors, and six hex head screws (1/4-20 x 1/2” (13mm).

Invert the plinth center and front assembly on a flat surface. Unpack the two end caps and invert them also, placing one at each end. Make sure the decorative fronts of the end caps are in line with the front of the plinth. (Fig. 60)

Place the stem end of the plinth connector on the plinth

Preassembled

Plinth Center/

Front

Preassembled

 

Hex

Plinth Center/

 

Head

 

Rear

 

Screws

 

 

Plinth End

Plinth Connector

 

Cap

 

 

FP1137

Fig. 60 Before attaching the end caps, make sure their decorative fronts line up with the front of the plinth.

with the connector hole centered over the tapped hole in the plinth. The other two holes in the plinth connec- tor should line up with the two tapped holes in the end caps. (If they do not line up, remove the plinth connec- tor and flip it over.)

Repeat this process for the other side. Attach the plinth connectors with the six (6) hex head cap screws pro- vided.

Set the assembled plinth in the upright position, in front of and centered on the WinterWarm. Adjust the levelling bolts on the bottom front of the fire chamber so that the plinth will fit, slide the plinth into its final position, and center it. Adjust the levelling bolts downward to lower the WinterWarm onto the plinth.

Step 16. Replace the Ashpan and Ash Door, Front Grate Bars, Bottom Grate and Load Door.

2000941

37

Image 37
Contents WinterWarm Introduction Table of ContentsWinterWarm SpecificationsYour WinterWarm’s Controls What They Do Section I OperationPrimary Air Control DamperFans Use the Air Control Settings That Work Best for YouBurn Only High-Quality Wood WinterWarm Control Settings How To Build a Wood Fire Keep It GoingHigh-Efficiency Wood Burning With Catalytic Combustion Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Open-Fire Viewing With the Screen Cassette Special Tactics for Cold-Climate HeatingRemove and Store Ash Safely Cleaning the Glass Section II MaintenanceCare of the Cast Iron Surface Care of the Porcelain Enamel SurfaceHow to Replace Gaskets Adjust the Door Latch PeriodicallyReplaceable WinterWarm Fiberglass Gaskets Replacing the Damper Gasket Replacing the Door GasketsReplace Damaged Door Glass Immediately Permanent WinterWarm GasketsTry the Fine Adjustment First Adjust the Damper as NeededUse the Coarse Adjustment Only If Necessary Care of the Catalytic CombustorInspection and Removal of the Combustor When to Suspect a Combustor ProblemWatch for Better Results Clean Chimney System is Safer and Works BetterLearn to Recognize and Avoid Creosote Yearly Spring Cleaning WinterWarm Maintenance ScheduleFireplace Daily Two WeeksPH4 Large WinterWarm Wiring DiagramSection III Preparing a Masonry Chimney Minimum Fireplace DimensionsRequirements for Existing Masonry Fireplace Requirements of your Existing Masonry ChimneyHearth Requirements Clearance RequirementsFireplace Maximums Flex Connector System Chimney ConnectorSealing Requirements Custom Damper Seal Install the Flex ConnectorRelined Chimney Remove the Masonry Fireplace DamperReverse the Flue Collar If Necessary Install the Floor ProtectorStructural Considerations Installation Chase Dimensions Section IV Installing the Fireplace System CabinetCarefully Observe Local Building Codes Selecting a Location for Your FireplaceChimney Requirements Duct and Vent Placementfloor protector must satisfy these requirements Guidelines for an Outside Air SupplyImportant Reminders Flush with the Floor or Laid Over It?Customizing the Finished Appearance Electrical RequirementsChoosing a Facing Material Use the Right Adhesives Prepare and Install WinterWarm Cabinet 40³⁄ ₈ 1026mm Install the optional cabinet convection blower kit Install the elevated base. Slide the base intoCabinet convection blower in place behind Prepare and Install WinterWarm Firechamber Section V Completing the WinterWarm InstallationConnect the Outside Air Duct to the Air Box Fireplace System onlyPrepare and Install the WinterWarm Front Attach the Rheostat Rod Linkages Connect the WiringInstall the Air Divider Install and Adjust the ControlsInstall the Mantel Install the Latticework PanelsFireplace Systems only Install the Plinth Move the Entire Unit the final few inches into the CabinetWinterWarm Large Insert WinterWarm Large Insert Classic Sand Midnight Shell Enamel Parts WinterWarm Large Insert ModelAppendixApproved Chimney Components Appendix Catalytic Combustor Warranty CFM Corporation