Appendix: Catalytic Combustor

In any chemical reaction, including the combustion process, there are certain conditions which must be met before the reaction can take place. For example, a reaction may require a certain temperature, or a certain concentration of the reactants (the combustion gases and oxygen), or a certain amount of time. Catalysts, though not changed themselves during the reaction, have the ability to act at a molecular level to change these requirements. In the secondary combustion chamber of the WinterWarm, the catalyst reduces the temperature at which secondary combustion can start from the 1000 - 1200°F (540 - 650°C) range to the 500

-600°F (260 - 315°C) range, increasing efficiency, and reducing creosote and emissions.

The catalytic reaction, though advantageous, does have some limitations of its own. Primary among these is that the reactants (the gases) come into close physi- cal contact with the catalyst itself.

To ensure the necessary contact, the catalytic element in your WinterWarm is composed of a ceramic base in the shape of a honeycomb. On each of the honey- comb’s many surfaces a coating of the catalyst (usually a noble metal such as platinum or palladium) is applied. The large surface area exposed in this configuration ensures the combustion gases have the greatest oppor- tunity to come in contact with the catalyst.

Loss of catalytic activity will be apparent in several ways. First you may notice an increase in fuel con- sumption. Second, there will be a visible increase in the rate at which creosote builds up in your chim- ney connector system. You may also notice a heavy discharge of smoke from the chimney. There are a number of catalytic problems which can cause loss of activity:

Blockage

While the honeycomb pattern ensures good contact, it also increases the resistance to flow of the combustion gases, and, because of the many surfaces, provides more places for creosote and fly ash to deposit. It is important to follow the operating instructions in order to minimize these deposits, and to periodically inspect your catalyst for signs of blockage.

Masking and Poisoning

While the catalyst itself does not enter into the combus- tion process, it is possible for certain elements, such as lead and sulfur, to attach to the active sites on the surface of the honeycomb. Though the catalyst is still there, it is covered, or masked, by the contaminant, and cannot function. To avoid this situation, it is im- portant not to burn anything in your WinterWarm that is a source of these contaminants. Particularly avoid painted or treated wood, coal, household trash, col- ored papers, metal foils, or plastics. Chemical chimney cleaners may also contain harmful elements. The safest approach is to burn only untreated, natural wood.

Flame Impingement

The catalytic element is not designed for exposure to direct flame. If you continually overfire your Winter- Warm, the chemistry of the catalyst coating may be altered, inhibiting the combustion process.

Thermal degradation of the ceramic base may also oc- cur, causing the element to disintegrate. Stay within the

recommended guidelines of the Operation section.

Mechanical Damage

If the element is mishandled, damage may occur. Always treat the element carefully. Remember the cata- lyst is made of a ceramic material; treat it as you would fine china. Hairline cracks will not affect the perfor- mance of the catalyst, as long as the steel sleeve holds the element in the proper position.

Peeling

Peeling of the surface coat may occur if the catalytic element is frequently subjected to excessive tempera- tures. Follow the operating instructions carefully to avoid this type of damage.

Every Vermont Castings’ product is equipped with either a Corning “Long-Life”®or a Technical Glass Products “Honeycomb”®. The products are equivalent. If for any reason you must ship your catalytic element, remem- ber its fragile nature. Place the element in a plastic bag, and package it with a generous amount of shock absorbing material.

42

2000941

Image 42
Contents WinterWarm Table of Contents IntroductionSpecifications WinterWarmPrimary Air Control Section I OperationYour WinterWarm’s Controls What They Do DamperUse the Air Control Settings That Work Best for You FansBurn Only High-Quality Wood High-Efficiency Wood Burning With Catalytic Combustion How To Build a Wood Fire Keep It GoingWinterWarm Control Settings Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Special Tactics for Cold-Climate Heating Open-Fire Viewing With the Screen CassetteRemove and Store Ash Safely Care of the Cast Iron Surface Section II MaintenanceCleaning the Glass Care of the Porcelain Enamel SurfaceAdjust the Door Latch Periodically How to Replace GasketsReplaceable WinterWarm Fiberglass Gaskets Replace Damaged Door Glass Immediately Replacing the Door GasketsReplacing the Damper Gasket Permanent WinterWarm GasketsUse the Coarse Adjustment Only If Necessary Adjust the Damper as NeededTry the Fine Adjustment First Care of the Catalytic CombustorWhen to Suspect a Combustor Problem Inspection and Removal of the CombustorClean Chimney System is Safer and Works Better Watch for Better ResultsLearn to Recognize and Avoid Creosote Fireplace Daily WinterWarm Maintenance ScheduleYearly Spring Cleaning Two WeeksLarge WinterWarm Wiring Diagram PH4Requirements for Existing Masonry Fireplace Minimum Fireplace DimensionsSection III Preparing a Masonry Chimney Requirements of your Existing Masonry ChimneyClearance Requirements Hearth RequirementsFireplace Maximums Chimney Connector Flex Connector SystemSealing Requirements Relined Chimney Install the Flex ConnectorCustom Damper Seal Remove the Masonry Fireplace DamperInstall the Floor Protector Reverse the Flue Collar If NecessaryCarefully Observe Local Building Codes Section IV Installing the Fireplace System CabinetStructural Considerations Installation Chase Dimensions Selecting a Location for Your FireplaceDuct and Vent Placement Chimney RequirementsGuidelines for an Outside Air Supply floor protector must satisfy these requirementsFlush with the Floor or Laid Over It? Important RemindersElectrical Requirements Customizing the Finished AppearanceChoosing a Facing Material Use the Right Adhesives Prepare and Install WinterWarm Cabinet 40³⁄ ₈ 1026mm Install the elevated base. Slide the base into Install the optional cabinet convection blower kitCabinet convection blower in place behind Section V Completing the WinterWarm Installation Prepare and Install WinterWarm FirechamberFireplace System only Connect the Outside Air Duct to the Air BoxPrepare and Install the WinterWarm Front Connect the Wiring Attach the Rheostat Rod LinkagesInstall and Adjust the Controls Install the Air DividerFireplace Systems only Install the Plinth Install the Latticework PanelsInstall the Mantel Move the Entire Unit the final few inches into the CabinetWinterWarm Large Insert WinterWarm Large Insert Shell Enamel Parts WinterWarm Large Insert Model Classic Sand MidnightAppendixApproved Chimney Components Appendix Catalytic Combustor Warranty CFM Corporation