DVS 30-2 installation instructions Example of Installation

Page 51

6.Insert damper rod through damper rod bracket and 3/8" diameter hole in cover plate. Insert damper rod into 1/4" diameter hole in damper door tab. Place smooth side of 1/2" diameter pushnut over end of damper rod. Press the pushnut onto the damper rod approximately 1/8". The pushnut will prevent the damper rod from falling out of 1/4" diameter hole in damper door tab.

7.Attach cover plate to support legs with (4) 10 x 1/2" provided screws. The support legs are on the left side, to the rear, in the interior bottom of fireplace.

8.The 1 1/4" offset on damper rod is used to secure the damper door in an open or closed position.

9.Refer to Figure 4 for options available for installation of 6" diameter duct. The duct run can be a maximum length of 40 feet. Insulated duct is recommended when ducting through a heated space. Note: 6" C vent or 6" flex vent can be used.

Figure 4 Example of Installation

NO ELBOWS USED ON FRESH AIR KIT

10.Cut a 6" diameter hole in structure after determining duct termination (rain cap) location.

11.Caulk exterior of structure that will be contacted by outside air tube assembly (See Figure 5).

12.Insert outside air tube assembly into 6" diameter hole in structure. Align clearance holes on rain cap with clearance holes on outside air tube assembly. Attach rain cap and outside air tube assembly to structure with (6) 1 1/2" provided screws.

13.Attach 6" diameter duct to 1 1/2" collar on damper assembly.

14.Route 6" diameter duct to outside air tube assembly.

15.Attach 6" diameter duct to outside air tube assembly.

16.Installation of fresh air intake kit is completed.

PARTS LIST

Part

Part

Quantity

Description

Number

Supplied

 

 

 

Damper Assembly

10098

1

 

 

 

6 3/8" Cover Plate (30")

11679

1

 

 

 

6 3/8" Cover Plate (36" & 42")

10083

1

 

 

 

Rain Cap

10124

1

 

 

 

Damper Rod 30"

R-6157

1

 

 

 

Damper Rod 36" & 42"

R-4182

1

 

 

 

Pushnut

R-4607

1

 

 

 

10 x 1/2" Screw

R-2737

6

 

 

 

10 x 1 1/2" Screw

R-1134

6

 

 

 

CAULKING

RAIN CAP

DUCT TERMINATION

WALL

Figure 5 Caulk and Install Duct Termination

WHEN 90° OR 45° ELBOWS ARE USED ON FRESH AIR KIT

Figure 6

13369-1-0203

Page 51

Image 51
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction Fireplace Dimensions Model DVS-30/DVS-36/DVS-42 SpecificationsHeater Baffle is Used on DVS-36 & DVS-42 only Fireplace Component InstallationClearances Figure Mantel Chart FigureClearances Locating FireplaceInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Example B InstallationVenting Fireplace Example aVent Runs Figures 14, 15, 16, 17 Three 3 basic types of installationsFraming Figure Finishing FigureInstallation Vertical Sidewall Application Positioning the Fireplace Cutting the Hole Figures 22 MAXVertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Installing Vent Components Figure Vent System IdentificationInner flue joints do not require any sealant Installing Support Brackets Figure Installing Firestops Figures 30, 31, 32DVS-30 Framing and Finishing DVS-30 Framing and Finishing DVS-36 & DVS-42 Framing and Finishing Installing Firestops Figures 35, 36, 37DVS-36 & DVS-42 Framing and Finishing Vertical Termination For All Models Installing the Vent System in a ChaseGlass Removal LOG PlacementReassembly and Resealing Vent Pipe System Vertical Through the Roof Applications FigureTOP View of LOG SET Glass ReplacementDVS-30 Placement of glowing embers DVS-36 and DVS-42 Placement of glowing embersStanding Pilot Operating Instructions Flame AppearanceMillivolt System Figures 48 Recommended Wire Gauges Standing Pilot Wiring Diagram What to do if YOU Smell GAS Standing Pilot Lighting InstructionsGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationElectrical Connection Figure DVS-36 & DVS-42 Intermittent Pilot Wiring DiagramTo Turn OFF GAS to Appliance Checkout SpecificationsOperation Trial for IgnitionMain Burner Operation Safety LockoutARC Length Action Ignition System ChecksDVS-36 & DVS-42 Intermittent Pilot Troubleshooting RF Standing Pilot Operating Instructions RF Wiring Diagram RF Standing Pilot Lighting Instructions Please Note Maintenance and ServiceDVS-30 Parts List HOW to Order Repair Parts#41 Orifice NAT DVS-36 Parts ListDVS-42 Parts List Parts View Louvers Accessory PartsVariable Speed Blower Installation Instructions Blower Motor FBB1A Blower Installation Optional Single Speed Blower Installation InstructionsParts List Optional Fresh Air Intake Kit Figure Optional Fresh AIR Intake KIT DVFB-AK-30, FB-AK-2Example of Installation DVS-BL-30-2, DVS- BL-36-2, DVS-BL-42-2 Installing Optional Brick LinerParts List Brick Liner KIT