DVS 30-2 installation instructions HOW to Order Repair Parts, DVS-30 Parts List

Page 41

HOW TO ORDER REPAIR PARTS

Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give all this information . . .

Fireplace Number

 

 

 

Part Description

 

Fireplace Serial Number

 

 

Part Number

 

 

Type of Gas (Propane or Natural)

 

 

 

 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.

Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529

DVS-30 PARTS LIST

 

 

 

 

 

 

 

 

INDEX

PART

 

INDEX

PART

 

 

 

NO.

NUMBER

DESCRIPTION

NO.

NUMBER

DESCRIPTION

 

 

 

 

 

 

 

 

 

1

11785

UPPER CLEARANCE SPACER

37

P-253

ORIFICE FITTING

 

2

10285

TOP STANDOFF (2 REQ’D)

38

P-182

#55 ORIFICE - LP

 

3

11265

VENT COVER PLATE ASSEMBLY

38

P-252

#44 ORIFICE - NAT

 

4

11264

OUTER WRAPPER TOP

39

R-5676

AIR SHUTTER

 

5

11263

TOP HEAT SHIELD

40

P-251

COUPLING (NAT GAS ONLY)

 

6

10281

OUTER WRAPPER - LEFT

41

12356

BURNER BOX ASSEMBLY

 

7

11240

OUTER WRAPPER BACK

42

11543

BURNER SUPPORT - LEFT

 

8

10282

OUTER WRAPPER - RIGHT

43

11279

BURNER SUPPORT - RIGHT

 

9

10779

CORNER SHIELD

45

R-5705

PILOT ASSEMBLY - NATURAL (DVS-30)

 

11

10018

AIR DILLUTION COVER PLATE

45

R-5706

PILOT ASSEMBLY - LP (DVS-30)

 

12

10574

CORNER BRACE 2

45a

R-5710

THERMOPILE (DVS-30)

 

13

10573

CORNER BRACE 1

45b

R-5709

THERMOCOUPLE (DVS-30)

 

46

R-6116

PILOT ASSEMBLY - NATURAL (DVS-

 

14

12217

OUTER WRAPPER BOTTOM WELDED

 

 

 

30RF)

 

 

 

 

ASSEMBLY

 

 

 

 

 

 

46

R-6117

PILOT ASSEMBLY - LP (DVS-30RF)

 

15

10590

LOUVER ASSEMBLY - UPPER

 

46a

R-6761

THERMOPILE (2 REQ’D) (DVS-30RF)

 

16

11267

GLASS FRAME ASSEMBLY

 

47b

11245

FIREBOX BOTTOM WELDED ASSEMBLY

 

17

10591

LOUVER ASSEMBLY - LOWER

48

R-4053

DOOR LATCH (2 REQ’D)

 

18

R-6106

ADAPTER PIPE

49b

R-5454

GAS VALVE - NATURAL (DVS-30)

 

19

M-160

6 5/8" ADAPTER GASKET

49b

R-5455

GAS VALVE - LP (DVS-30)

 

49c

R-6114

GAS VALVE - NATURAL (DVS-30RF)

 

20

11261

AIR DROP BACK ASSEMBLY

 

49c

R-6115

GAS VALVE - LP (DVS-30RF)

 

21

10554

NAILING FLANGE (4 REQ’D)

 

50

M-173

PILOT GASKET

 

22

11259

AIR DROP FRONT ASSEMBLY

 

57

R-3436

REMOTE/OFF/ON SWITCH (DVS-30)

 

23

11250

PRESSURE DOOR RELEIF ASSEMBLY

58

11663

VALVE BRACKET (2 REQ’D) (DVS-30RF)

 

24

11252

PRESSURE RELEIF BRACKET (2 REQ’D)

59

R-6110

LOG - LEFT FRONT

 

25

M-163

FLUE CONNECTOR TUBE GASKET

60

R-6109

LOG - RIGHT FRONT

 

61

R-6111

LOG - MIDDLE

 

26

10994

DIVERTER OUTLET SUPPORT

 

62

R-6113

LOG - BRANCH

 

27

11247

FIREBOX TOP ASSEMBLY

 

63

R-6112

LOG - REAR

 

28

11253

COMBUSTION DOME DIVERTER

 

NOT SHOWN

11281

VENTURI TARGET (NAT ONLY)

 

30

11257

SUPPORT COLUMN - LEFT

NOT SHOWN

R-3435A

WIRE ASSEMBLY (DVS-30)

 

31

11254

FIREBOX SIDE - LEFT

NOT SHOWN

13097

INLET TUBING ASSEMBLY (DVS-30))

 

32

11255

FIREBOX SIDE - RIGHT

NOT SHOWN

11664

INLET TUBING ASSEMBLY (DVS-30RF)

 

33

11258

SUPPORT COLUMN - RIGHT

NOT SHOWN

R-6118

REMOTE CONTROL (DVS-30RF)

 

34

11256

FIREBOX BACK

NOT SHOWN

11495

SHIPPING PLATE

 

35

11645

REAR LOG SUPPORT

NOT SHOWN

11788

DECORATIVE ROCK

 

36

11646

GRATE ASSEMBLY (2 REQ’D)

NOT SHOWN

11548

ROCK WOOL (1 REQ’D)

 

 

 

 

 

NOT SHOWN

R-4459

MAGNET (2 REQ’D)

 

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

13369-1-0203

Page 41

Image 41
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction Fireplace Dimensions Model DVS-30/DVS-36/DVS-42 SpecificationsHeater Baffle is Used on DVS-36 & DVS-42 only Fireplace Component InstallationClearances Mantel Chart FigureLocating Fireplace Clearances FigureChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Venting Fireplace InstallationExample a Example BFraming Figure Three 3 basic types of installationsFinishing Figure Vent Runs Figures 14, 15, 16, 17Installation Vertical Sidewall Application Positioning the Fireplace Cutting the Hole Figures 22 MAXInformation on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Inner flue joints do not require any sealant Installing Vent Components FigureVent System Identification DVS-30 Framing and Finishing Installing Support Brackets FigureInstalling Firestops Figures 30, 31, 32 DVS-30 Framing and Finishing DVS-36 & DVS-42 Framing and Finishing Installing Firestops Figures 35, 36, 37DVS-36 & DVS-42 Framing and Finishing Vertical Termination For All Models Installing the Vent System in a ChaseReassembly and Resealing Vent Pipe System LOG PlacementVertical Through the Roof Applications Figure Glass RemovalDVS-30 Placement of glowing embers Glass ReplacementDVS-36 and DVS-42 Placement of glowing embers TOP View of LOG SETMillivolt System Figures 48 Standing Pilot Operating InstructionsFlame Appearance Recommended Wire Gauges Standing Pilot Wiring Diagram What to do if YOU Smell GAS Standing Pilot Lighting InstructionsFrequent pilot outage problem Standing Pilot TroubleshootingPilot and main burner extinguish while in operation Glass sootsElectrical Connection Figure DVS-36 & DVS-42 Intermittent Pilot Wiring DiagramTo Turn OFF GAS to Appliance Operation SpecificationsTrial for Ignition CheckoutMain Burner Operation Safety LockoutARC Length Action Ignition System ChecksDVS-36 & DVS-42 Intermittent Pilot Troubleshooting RF Standing Pilot Operating Instructions RF Wiring Diagram RF Standing Pilot Lighting Instructions Please Note Maintenance and ServiceDVS-30 Parts List HOW to Order Repair Parts#41 Orifice NAT DVS-36 Parts ListDVS-42 Parts List Parts View Louvers Accessory PartsVariable Speed Blower Installation Instructions Blower Motor FBB1A Blower Installation Optional Single Speed Blower Installation InstructionsParts List Optional Fresh Air Intake Kit Figure Optional Fresh AIR Intake KIT DVFB-AK-30, FB-AK-2Example of Installation Parts List Installing Optional Brick LinerBrick Liner KIT DVS-BL-30-2, DVS- BL-36-2, DVS-BL-42-2