DVS 30-2 installation instructions Variable Speed Blower Installation Instructions

Page 46

VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS

Optional FB-BK-2 Blower Installation

and

Factory Installed FB-BK-RF Blower

1.If applicable, turn OFF electric supply to fireplace.

2.Lower bottom louver.

3.With a 5/16" socket, loosen but do not remove either left screw or right screw that attaches bottom louver to fireplace side.

4.When the screw is sufficiently loosened you will be able to pull and pivot the bottom louver out of fireplace.

5.Centered in the rear are two (2) weld studs which protrude upward into the bottom of fireplace for attachment of fan.

6.Insert fan into interior, bottom of fireplace. The clearance holes on fan mounting bracket must be facing toward the front of fireplace. Do not damage gas inlet supply line when fan is inserted into fireplace.

7.Align and place rear set of clearance holes on fan mounting bracket onto two (2) weld studs for direct vent 36/42 models or front set of clearance holes on fan mounting bracket onto two

(2) weld studs for other models.

8.Use two (2) wing nuts to attach blower to weld studs.

9.Depending on the appliance, you will remove the top louver(s) by one of the following methods.

First Method, Push up and outward to remove top louver. Second Method, Remove top louvers by grasping an individual

louver at each end and pivoting louver out of frame. Remove three (3) additional louvers in this same manner.

Attention: Steps 10 through 17 DO NOT apply to RF models.

10.Located in the right, front are two (2) weld studs which protrude upward into the bottom of fireplace for attachment of speed control.

11.Insert speed control into interior, bottom of fireplace. Align and place two (2) clearance holes on speed control onto two (2) weld studs.

12.Use two (2) wing nuts to attach speed control to weld studs.

13.Refer to Figure 1 for mounting hole location on right side of firebox top that applies to your appliance. Measure from front edge of firebox top to determine mounting hole location. Remove appropriate screw from firebox top.

14.Refer to Figure 2 for fan control bracket location that applies to your firebox. Align clearance hole on fan control bracket with screw hole on firebox top. Attach fan control bracket to firebox top with one (1) screw from Step 13.

15.Route fan control wires between the inner casing and outer casing.

16.Connect fan control wires to speed control wires.

17.Plug speed control electric cord into junction box on the right side of fireplace.

18.For RF Models only, insert one (1) 1/4" terminal wire from RF cordset and one (1) 1/4" terminal wire from blower motor into gas valve. Insert cap wire into plug wire from cordset and blower motor. Secure ground wire.

19.Depending on the appliance, you will replace the top louver(s) by one of the following methods.

First Method, Align and insert (4) mounting tabs on top louver with (4) slots on casing top. Push downward to lock the top louver into position.

Second Method, Install top louvers by grasping an individual louver at each end and pivoting louver onto end brackets on frame. Install three (3) additional louvers in this same manner.

20.Replace bottom louver.

21.Installation of blower is completed.

Figure 1

Figure 2

Page 46

13369-1-0203

Image 46
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP-GAS LP-GAS Warning OdorIntroduction Specifications Fireplace Dimensions Model DVS-30/DVS-36/DVS-42Fireplace Component Installation Heater Baffle is Used on DVS-36 & DVS-42 onlyLocating Fireplace Mantel Chart FigureClearances Clearances FigureGAS Supply Installing a New Main Gas CockChecking Manifold Pressures Example a InstallationVenting Fireplace Example BFinishing Figure Three 3 basic types of installationsFraming Figure Vent Runs Figures 14, 15, 16, 17Installation Vertical Sidewall Application Positioning the Fireplace MAX Cutting the Hole Figures 22Termination Clearances Vertical Sidewall InstallationsInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Vent Components FigureInner flue joints do not require any sealant Installing Firestops Figures 30, 31, 32 Installing Support Brackets FigureDVS-30 Framing and Finishing DVS-30 Framing and Finishing Installing Firestops Figures 35, 36, 37 DVS-36 & DVS-42 Framing and FinishingDVS-36 & DVS-42 Framing and Finishing Installing the Vent System in a Chase Vertical Termination For All ModelsVertical Through the Roof Applications Figure LOG PlacementReassembly and Resealing Vent Pipe System Glass RemovalDVS-36 and DVS-42 Placement of glowing embers Glass ReplacementDVS-30 Placement of glowing embers TOP View of LOG SETFlame Appearance Standing Pilot Operating InstructionsMillivolt System Figures 48 Recommended Wire Gauges Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions What to do if YOU Smell GASPilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsDVS-36 & DVS-42 Intermittent Pilot Wiring Diagram Electrical Connection FigureTo Turn OFF GAS to Appliance Trial for Ignition SpecificationsOperation CheckoutSafety Lockout Main Burner OperationIgnition System Checks ARC Length ActionDVS-36 & DVS-42 Intermittent Pilot Troubleshooting RF Standing Pilot Operating Instructions RF Wiring Diagram RF Standing Pilot Lighting Instructions Maintenance and Service Please NoteHOW to Order Repair Parts DVS-30 Parts ListDVS-36 Parts List #41 Orifice NATDVS-42 Parts List Parts View Accessory Parts LouversVariable Speed Blower Installation Instructions Blower Motor Optional Single Speed Blower Installation Instructions FBB1A Blower InstallationParts List Optional Fresh AIR Intake KIT DVFB-AK-30, FB-AK-2 Optional Fresh Air Intake Kit FigureExample of Installation Brick Liner KIT Installing Optional Brick LinerParts List DVS-BL-30-2, DVS- BL-36-2, DVS-BL-42-2