Enviro C-11102, C-11253, 50-1472 owner manual Component Sound & Reason, Remote Control Instruction

Page 10

Operating Instructions

NOTE: The remote handset control instructions are on inside of remote’s battery cover plate (see Figure 7).

Figure 7. Remote Control Instruction.

CONTROL PANEL:

Press the larger flame to increase flame height. Press the smaller flame to decrease flame height. For fine adjustment tap the appropriate flame icon, refer to Figure 4. Can also be use to turn unit on or off.

BLOWER SPEED:

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). Pressing the fan’s three (3) position rocker switch on the unit’s control panel will change the speed of the fan; it is Low/Off/High (refer to Figure 4). The fan can not be controlled with the handset.

NORMAL SOUNDS DURING OPERATION:

 

Table 2: Normal Sounds.

 

 

Component

Sound & Reason

 

 

Sonnet & Surrounds

Creaking when heating up or cooling down.

 

 

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

Temperature Sensor

Clicking when it senses to turn the blower on or off.

 

 

Blower / Fan

Air movement that increase and decreases with the speed of the blower.

 

The blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

ADJUSTING VENTURI AIR SETTINGS:

There is one venturi adjustment. Use this venturi adjustment lever, shown in Figure 8, to achieve a proper and efficient flame. Pull the rod forward for more air or push it in for less air. Adjust lever until the flame pattern is similar to Figure 79.

Figure 8: Adjusting the venturi air setting.

10

Image 10
Contents For Your Safety InstallerConsumer Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsAutomatic Pilot Mode Setting the TimeSetting C/24 hour or F/12 hour Clock Adjustment of Flame HeightSetting the Temperature Changing the Mode of OperationMAN Mode Manual Flame Height Adjustment Setting the TimerRemote Control Instruction Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverMethods for Resetting the Receiver Method 1 From Outside the CabinetTo be Installed by a Qualified Service Agency only Kit Parts List Conversion Kit InstallationIs pointing out then the valve is Initial Installation Mantle width and heightQualified Installers only Kit Contents Quantity Description Vent Kit InstallationInstall of Intake Air Plug Venting Fireplace Inserts Installation of Sonnet DV and BV DescriptionInstallation Instructions KIT ComponentsVertical Vent Cap Underside Electrical Requirements Fan Kit Installation Removing/Installing Back PanelFan Only Replacement Gas Line ConnectionTo Test Valve Pressures Labeled Gas ValveInstallation Options Proper Pilot FlameSecondary Installation InstallationAssembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’sBV only Parts List Reference Part Description Part NumberOption Description Parts ListNumber Parts Diagram Components Parts Diagram Options Warranty To the DealerWarranty Warranty Installation Data Sheet