Enviro C-11253, C-11102, 50-1472 owner manual Venting Fireplace Inserts

Page 21

Initial Installation

QUALIFIED INSTALLERS ONLY

3.Remove screw from draft tube and remove air intake covers.

a)Remove the glass door as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL.

b)Using a T-20 screwdriver remove the screw that is in the draft tube pointed at in Figure 30.

c)Remove the two (2) air intake covers below the firebox (refer to Figure 38), they can be pried out using a flat head screwdriver.

d)Install door.

4.Test fire the appliance and ensure proper operation. A venturi adjustment (Figure 8) could be required to achieve an efficient flame, refer to Figure 79. Improper operation or adjustment could result in Carbon Monoxide production causing personal injury or property damage.

Note: To convert a B-Vent to a Direct Vent, remove the air intake plug, remove the spill switch assembly and re-install the flue slider bottom plate, re-install the jumper onto the thermocouple wire, re-install the air intake cover plates, install the proper venting, re-install the screw into the draft tube at the

front top of the unit.

Figure 38: Air Intake Cover Plates.

VENTING FIREPLACE INSERTS:

The ENVIRO Sonnet may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. Before starting, refer to INITIAL INSTALLATION - PREPARING YOUR SONNET FOR

INSTALLATION and INITIAL INSTALLATION - CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE. Please

reference the information in Table 5 and Figures 39, 40, and 43.

An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s instructions that accompany the chimney liner kit. Use listed B-Vent or Flexmaster double walled aluminum flex vent.

If necessary, remove the vent collar plate from the top of the insert and connect it securely to the liner with sheet metal screws and/or hose clamps. Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed.

Provide for proper and adequate venting and air supply for this appliance in accordance with the tables in the current National Fuel Gas Code, Z223.1/NFPA 54 or the CSA B149.1.

NOTE: If the Sonnet unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant or silicone and reconnected with three

(3) sheet metal screws evenly spaced.

2ft (0.6m)

Roof ridge or

Minimum

3ft (0.9m)

any other portion

of a building

Minimum

Within

 

10ft (3m)

Figure 39: Roof Clearances.

21

Image 21
Contents Installer For Your SafetyConsumer General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater Sonnet BV/DV NG/LPG Codes And ApprovalsDimensions SpecificationsTrimmable Lighting and Turning OFF Instructions Operating InstructionsSetting C/24 hour or F/12 hour Clock Setting the TimeAutomatic Pilot Mode Adjustment of Flame HeightMAN Mode Manual Flame Height Adjustment Changing the Mode of OperationSetting the Temperature Setting the TimerComponent Sound & Reason Remote Control InstructionPilot Flame Maintenance And ServiceReceiver Remote HandsetMethod 1 From Outside the Cabinet Methods for Resetting the ReceiverTo be Installed by a Qualified Service Agency only Conversion Kit Installation Kit Parts ListIs pointing out then the valve is Mantle width and height Initial InstallationQualified Installers only Vent Kit Installation Kit Contents Quantity DescriptionInstall of Intake Air Plug Venting Fireplace Inserts Description Installation of Sonnet DV and BVKIT Components Installation InstructionsVertical Vent Cap Underside Electrical Requirements Removing/Installing Back Panel Fan Kit InstallationGas Line Connection Fan Only ReplacementLabeled Gas Valve To Test Valve PressuresProper Pilot Flame Installation OptionsInstallation Secondary InstallationScrew Hook Bracket To the Trim AssemblyMinimum size of Large Removal InstallationEnsure the Sonnet is turned off and allow the unit to cool Hook PlacementsEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Never operate the fireplace with the glass door removed Log Set and Ember InstallationProblem Possible Cause Solution Trouble ShootingValve’s Possible Cause SolutionBV only Reference Part Description Part Number Parts ListParts List Option DescriptionNumber Parts Diagram Components Parts Diagram Options To the Dealer WarrantyWarranty Warranty Installation Data Sheet