Initial Installation
QUALIFIED INSTALLERS ONLY
3.Remove screw from draft tube and remove air intake covers.
a)Remove the glass door as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL.
b)Using a
c)Remove the two (2) air intake covers below the firebox (refer to Figure 38), they can be pried out using a flat head screwdriver.
d)Install door.
4.Test fire the appliance and ensure proper operation. A venturi adjustment (Figure 8) could be required to achieve an efficient flame, refer to Figure 79. Improper operation or adjustment could result in Carbon Monoxide production causing personal injury or property damage.
Note: To convert a
front top of the unit.
Figure 38: Air Intake Cover Plates.
VENTING FIREPLACE INSERTS:
The ENVIRO Sonnet may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of
INSTALLATION and INITIAL INSTALLATION - CONVERTING A DIRECT VENT FIREPLACE TO A
reference the information in Table 5 and Figures 39, 40, and 43.
An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s instructions that accompany the chimney liner kit. Use listed
If necessary, remove the vent collar plate from the top of the insert and connect it securely to the liner with sheet metal screws and/or hose clamps. Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed.
Provide for proper and adequate venting and air supply for this appliance in accordance with the tables in the current National Fuel Gas Code, Z223.1/NFPA 54 or the CSA B149.1.
NOTE: If the Sonnet unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the
(3) sheet metal screws evenly spaced.
2ft (0.6m) | Roof ridge or |
Minimum | |
3ft (0.9m) | any other portion |
of a building | |
Minimum | Within |
| 10ft (3m) |
Figure 39: Roof Clearances.
21