Initial Installation

QUALIFIED INSTALLERS ONLY

6.Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø2” (51mm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

7.At the top of the chimney, apply a bead of Mill-Pac Black sealant to the Ø3” (76mm) pipe of the vent terminal (refer to Figure 42). Slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced.

8.Place a bead of high temperature silicone on the intake collar of the vent terminal (refer to Figure 42). Slide the Ø2” (51mm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced.

9.Make a tight connection between the gas fireplace insert flue collar and the fireplace chimney at the top of the chimney. Secure the vent terminal to the chimney using adequate sealant, and according to local building codes.

10.Light the Sonnet and ensure proper operation and proper flame appearance. The amount of air to the venturi may need to be adjusted using the rod under the firebox (see Figure 8). Also refer to Figure 79 for a flame appearance picture.

3" (76mm) Exhaust

2" (51mm) Air Inlet

Figure 42: Vertical Vent Cap Underside.

The height for the vent must be between 10ft (3.05m) and 35ft (10.67m).

Install sealed Vertical Vent Cap to prevent leakage of room air up through chimney.

The intake is 2" (51mm) and the exhaust is 3" (76mm).

Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over-stretch a flexible liner to accommodate the height of the chimney. Any chimney over 15' (4.6m), install the Sonnet 15’ 2” & 3” Flex Vent (part #50-1512) and the Sonnet 2” & 3” Flex Couplers (part #50-1513). Every joint in the venting must be secured with three (3) #8 x 3/8” HWH sheet metal screws and an appropriate sealant (either silicone or milpac).

The flue damper can be fully blocked open or removed for installation of

the Sonnet; the smoke shelves, shields and baffles may be removed if

attached by mechanical fasteners.

The chimney must be clean, in good working order and constructed of non-combustible materials.

Make sure that all chimney cleanouts are tight fitting and will not permit air to leak into the chimney.

Refractory, glass doors, screen rails, screen mesh and log grates can be removed from the fireplace before installing the Sonnet.

Figure 43: Installation of Sonnet DV .

24

Image 24
Contents Installer For Your SafetyConsumer Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsSetting the Time Setting C/24 hour or F/12 hour ClockAutomatic Pilot Mode Adjustment of Flame HeightChanging the Mode of Operation MAN Mode Manual Flame Height AdjustmentSetting the Temperature Setting the TimerRemote Control Instruction Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverMethods for Resetting the Receiver Method 1 From Outside the CabinetTo be Installed by a Qualified Service Agency only Kit Parts List Conversion Kit InstallationIs pointing out then the valve is Initial Installation Mantle width and heightQualified Installers only Kit Contents Quantity Description Vent Kit InstallationInstall of Intake Air Plug Venting Fireplace Inserts Installation of Sonnet DV and BV DescriptionInstallation Instructions KIT ComponentsVertical Vent Cap Underside Electrical Requirements Fan Kit Installation Removing/Installing Back PanelFan Only Replacement Gas Line ConnectionTo Test Valve Pressures Labeled Gas ValveInstallation Options Proper Pilot FlameSecondary Installation InstallationAssembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’sBV only Parts List Reference Part Description Part NumberParts List Option DescriptionNumber Parts Diagram Components Parts Diagram Options Warranty To the DealerWarranty Warranty Installation Data Sheet