Enviro 50-1472 Setting the Time, Setting C/24 hour or F/12 hour Clock, Automatic Pilot Mode

Page 8

Operating Instructions

The Sonnet is designed to gradually lower or raise the flame as is needed in application. It normally does not just turn on and off. This is very dependant on the size of the room the unit is located in. During the first several operational cycles the electronics go through a learning process that establishes how the system will react to the environment it is in. It does so by determining the amount of time it takes for the temperature to rise 1°. It does this several times to maintain consistency. Once this has been learned it will respond the same way each time it is used. It is possible to relearn by removing the batteries from the receiver and re installing the batteries after several minutes have past. If there is no call for heat and the unit is in the lowest operation condition the valve will turn the burner to the off position. When there is a subsequent call for heat the burner will turn back on at the low setting. Should this not be adequate in application the valve will open more to allow more gas flow to the burner.

REMOTE HANDSET CONTROLS:

The remote handset included with this unit has a thermostat in its control system and a design feature that will turn off the unit if there is a no communicate condition caused by the handset being removed from the normal range of operation (up to 20-25ft (6.1-7.6m)) or a low battery condition in either the receiver or the hand set. If one or more Sonnets are to be installed, confirm that the remote control signal

codes are different for each unit, refer to MAINTENANCE AND SERVICE - CHANGING REMOTE HANDSET CODE.

Setting the Time

1.The display will flash after either: (a) Installing the battery or (b) Simultaneously pressing the (up arrow) and (down arrow).

2.Press (up arrow) to set the hour and the (down arrow) to set the minute.

3.Press OFF to return to manual mode or simply wait and it will automatically return to the manual mode.

Setting °C/24 hour or °F/12 hour Clock:

Press OFF and (down arrow) until display changes from Farenheit/12 hour clock to Celcius/24 hour clock and vice versa.

Automatic Pilot Mode:

If there is no transmission from the handset to the receiver within a six (6) hour period, the unit will go to standby (pilot) mode.

Adjustment of Flame Height:

In standby mode: Press

(up arrow) to increase flame height. Press

(down arrow) to decrease flame height or to set appliance at pilot

flame. For fine adjustment tap the up/down arrows.

 

 

 

Mode Settings:

 

Figure 6: Remote Control.

 

 

TEMP MODE – Daytime Temperature Mode (appliance must be in standby mode; pilot ignited): The room temperature is measured and compared to the set temperature. The flame height is then automatically adjusted to achieve the Daytime set temperature. This mode is manually turned on and off.

TEMP MODE – Nighttime Setback Temperature Mode (appliance must be in standby mode; pilot ignited): The room temperature is measured and compared to the Nighttime Setback temperature. The flame height is then automatically adjusted to achieve the Nighttime Setback temperature. This mode is manually turned on and off.

8

Image 8
Contents Consumer InstallerFor Your Safety Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsSetting the Time Setting C/24 hour or F/12 hour ClockAutomatic Pilot Mode Adjustment of Flame HeightChanging the Mode of Operation MAN Mode Manual Flame Height AdjustmentSetting the Temperature Setting the TimerRemote Control Instruction Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverMethods for Resetting the Receiver Method 1 From Outside the CabinetTo be Installed by a Qualified Service Agency only Kit Parts List Conversion Kit InstallationIs pointing out then the valve is Initial Installation Mantle width and heightQualified Installers only Kit Contents Quantity Description Vent Kit InstallationInstall of Intake Air Plug Venting Fireplace Inserts Installation of Sonnet DV and BV DescriptionInstallation Instructions KIT ComponentsVertical Vent Cap Underside Electrical Requirements Fan Kit Installation Removing/Installing Back PanelFan Only Replacement Gas Line ConnectionTo Test Valve Pressures Labeled Gas ValveInstallation Options Proper Pilot FlameSecondary Installation InstallationAssembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’sBV only Parts List Reference Part Description Part NumberNumber Parts ListOption Description Parts Diagram Components Parts Diagram Options Warranty To the DealerWarranty Warranty Installation Data Sheet