Enviro C-11102, C-11253, 50-1472 owner manual To Test Valve Pressures, Labeled Gas Valve

Page 28

Initial Installation

QUALIFIED INSTALLERS ONLY

A shut-off valve is not supplied with this unit but one should be installed.

The appliance and its shut-off valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1⁄2 psig (3.45 KPa) or the valve will be damaged.

The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at pressures equal to or less than 1⁄2 psig (3.45 KPa).

Table 6: Orifice and Pressure Information.

Main Burner

Natural Gas

Propane Gas

 

 

 

Orifice:

#42 DMS

#54 DMS

 

 

 

Manifold Press:

4.0 W.C. (0.99 KPa)

10.0 W.C. (2.47 KPa)

 

 

 

Min. Manifold Press:

0.2 W.C. (0.05 KPa)

2.3 W.C. (0.57 KPa)

Max. Supply Press:

7.0 W.C. (1.74 KPa)

13.0 W.C. (3.28 KPa)

Min. Supply Press:

5.0 W.C. (1.24 KPa)

12.0 W.C. (2.96 KPa)

 

 

 

 

 

Max. Input:

26,600 BTU/hr

(7.79 KW)

21,300 BTU/hr

(6.24 KW)

 

 

 

 

 

Min. Input:

6,500 BTU/hr

(1.9 KW)

11,400 BTU/hr

(3.34 KW)

 

 

 

 

 

TO TEST VALVE PRESSURES:

The pressure taps are located on the front side of the valve (see Figure 51 & 52).

1.Follow steps 1-4 in REMOVING VALVE COVER - MAINTENANCE

AND SERVICE. to access the valve.

2.

Turn set screw one (1) turn counter-clockwise to loosen.

 

3.

Place 5/16 in (8 mm) I.D. hose over the pressure taps.

 

4.

Check pressures using a manometer.

 

5.

When finished, release pressure, remove hose and tighten

 

 

set screw.

 

 

Figure 51: Labeled Gas Valve.

6.

Re-install the valve cover, burner tray, brick panels (refer to

 

 

SECONDARY INSTALLATION - INSTALLING THE BRICK PANELS), log

 

 

 

 

 

 

set and ember material (refer to SECONDARY INSTALLATION -

 

 

LOG SET AND EMBER INSTALLATION) and the glass door.

 

Always check for gas leaks with a soap and water solution after completing the required pressure test.

NEVER USE AN OPEN FLAME FOR

LEAK TESTING.

Figure 52: Opening Inlet Pressure Tap on

Valve.

28

Image 28
Contents For Your Safety InstallerConsumer Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Sonnet BV/DV NG/LPGSpecifications DimensionsTrimmable Operating Instructions Lighting and Turning OFF InstructionsSetting the Time Setting C/24 hour or F/12 hour ClockAutomatic Pilot Mode Adjustment of Flame HeightChanging the Mode of Operation MAN Mode Manual Flame Height AdjustmentSetting the Temperature Setting the TimerRemote Control Instruction Component Sound & ReasonMaintenance And Service Pilot FlameRemote Handset ReceiverMethods for Resetting the Receiver Method 1 From Outside the CabinetTo be Installed by a Qualified Service Agency only Kit Parts List Conversion Kit InstallationIs pointing out then the valve is Initial Installation Mantle width and heightQualified Installers only Kit Contents Quantity Description Vent Kit InstallationInstall of Intake Air Plug Venting Fireplace Inserts Installation of Sonnet DV and BV DescriptionInstallation Instructions KIT ComponentsVertical Vent Cap Underside Electrical Requirements Fan Kit Installation Removing/Installing Back PanelFan Only Replacement Gas Line ConnectionTo Test Valve Pressures Labeled Gas ValveInstallation Options Proper Pilot FlameSecondary Installation InstallationAssembly Screw Hook Bracket To the TrimMinimum size of Large Installation RemovalHook Placements Ensure the Sonnet is turned off and allow the unit to coolEmpty firebox showing the ledges for the back logs Third Stage Log Set Installation Log Set and Ember Installation Never operate the fireplace with the glass door removedTrouble Shooting Problem Possible Cause SolutionPossible Cause Solution Valve’sBV only Parts List Reference Part Description Part NumberOption Description Parts ListNumber Parts Diagram Components Parts Diagram Options Warranty To the DealerWarranty Warranty Installation Data Sheet