Initial Installation
QUALIFIED INSTALLERS ONLY
•A
•The appliance and its
•The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at pressures equal to or less than 1⁄2 psig (3.45 KPa).
Table 6: Orifice and Pressure Information.
Main Burner | Natural Gas | Propane Gas | ||
|
|
| ||
Orifice: | #42 DMS | #54 DMS | ||
|
|
| ||
Manifold Press: | 4.0 W.C. (0.99 KPa) | 10.0 W.C. (2.47 KPa) | ||
|
|
| ||
Min. Manifold Press: | 0.2 W.C. (0.05 KPa) | 2.3 W.C. (0.57 KPa) | ||
Max. Supply Press: | 7.0 W.C. (1.74 KPa) | 13.0 W.C. (3.28 KPa) | ||
Min. Supply Press: | 5.0 W.C. (1.24 KPa) | 12.0 W.C. (2.96 KPa) | ||
|
|
|
|
|
Max. Input: | 26,600 BTU/hr | (7.79 KW) | 21,300 BTU/hr | (6.24 KW) |
|
|
|
|
|
Min. Input: | 6,500 BTU/hr | (1.9 KW) | 11,400 BTU/hr | (3.34 KW) |
|
|
|
|
|
TO TEST VALVE PRESSURES:
The pressure taps are located on the front side of the valve (see Figure 51 & 52).
1.Follow steps
AND SERVICE. to access the valve.
2. | Turn set screw one (1) turn |
| ||
3. | Place 5/16 in (8 mm) I.D. hose over the pressure taps. |
| ||
4. | Check pressures using a manometer. |
| ||
5. | When finished, release pressure, remove hose and tighten |
| ||
| set screw. |
| ||
| Figure 51: Labeled Gas Valve. | |||
6. | ||||
| ||||
| SECONDARY INSTALLATION - INSTALLING THE BRICK PANELS), log |
|
| |
|
|
| ||
| set and ember material (refer to SECONDARY INSTALLATION - |
| ||
| LOG SET AND EMBER INSTALLATION) and the glass door. |
|
Always check for gas leaks with a soap and water solution after completing the required pressure test.
NEVER USE AN OPEN FLAME FOR
LEAK TESTING.
Figure 52: Opening Inlet Pressure Tap on
Valve.
28