Hampton Direct H25-LP1, H25-NG1 installation manual Glow on logs

Page 29

INSTALLATION

7)

Turn control knob to the “OFF” position.

12) Using the Allen wrench as shown in

 

 

Fig.4, rotate the screw clockwise until

8)

Remove the black protection cap by

snug, do not overtighten.

 

hand from the high-low knob (Fig.1).

 

 

 

 

 

 

 

15)

Reverse step 2.

16)

Attach the label "This unit has been

 

converted to LPG" near or on top of the

 

serial # decal.

17)

Replace yellow "NG" label with red

 

"LPG" label.

18)

Check for gas leaks.

19)

Check inlet and outlet pressures.

20)

Check operation of fl ame control.

Fig. 1

9)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

Fig.4

WARNING!

Do not overtighten the screw. Recommended to grip

the wrench by the short side.

13)Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (Fig. 5).

21) Check for proper fl ame appearance and

glow on logs.

Red o-ring visible

Fig.5

LPG Configuration

Fig.2

10)Check that the screw is clean and if necessary remove dirt.

11)Flip the screw (Fig. 3).

Fig.3

14)Re-assemble the black protection cap (Fig. 6).

Fig. 6

WARNING!

Also check that the pilot and

main burner injectors

are appropriate for the gas type.

Hampton® H25-1 Direct Vent Freestanding Gas Stove

29

Image 29
Contents H25 Direct Vent Gas Fireplace To the New Owner Unit DimensionsHampton Table of Contents Copy of Safety Label for H25-NG1 & H25-LP1 Safety LabelMA Code CO Detector RequirementsImportant Message InstallationInstructions Before YOU StartInstallation Checklist General Safety InformationClearances to Combustibles This includesLocating Your GAS Stove Optional FAN InstallationManufactured Mobile Home Additional Requirements Fan Kit ContainsInstallation Vent Restrictor Position PrecautionsRotating 45O Elbow Remove all 4 screws WashersExterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsHorizontal CapsDura-Vent Snorkel Termination Venting Arrangements+ H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsStraight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemDescription Alternate Approved CapsQty. Description DV Stove Horizontal Vent KITMust be used to ensure that the termination is not Optional Components Planning Your venting InstallationMinimum components for a Horizontal Installation DURA-VENT Termination KIT Planning Your Dura-Vent InstallationDURA-VENT Venting Dura-Vent Basic Horizontal Kit #Horizontal Terminations Below Grade Snorkel InstallationMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsVertical Terminations Offset Chart Converting a Factory Built Metal Chimney Approved for US Installations OnlyCathedral Ceilings Aeration AdjustmentHigh Elevation GAS ConnectionClockwise to open Counter-clockwise to close GAS Pipe Pressure TestingValve Description LPG Conversion Kit Contains Qty Conversion KIT #434-969 from NG to LPGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Shut off the gas supply LOG SET InstallationLift off the Cast Top and remove the Glass Front see manual Are fragile, handle with care do not force into positionLogs must be oriented as shown below Wall Thermostat Remote ControlOn an interior wall Rear View Decorative Door GrillFinal Check Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions LOG Replacement FAN MaintenanceGlass Replacement Replacement 946-327 GlassTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve ScrewsMain Assembly Parts ListBurner & LOG Assembly Conditions WarrantyInstaller Please complete the following information