INSTALLATION

DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the H25 Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termination Kit" and "Dura-Vent Venting Components" sections.

Qty. Description

1)1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

 

 

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm)

 

 

inside diameter

2)

1

Flex Liner, compressed aluminium 2 ply liner, 4" (102mm)

 

 

inside diameter

3)

4

spring spacers

4)

1

90 deg. Elbow

5)

1

Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.

6)

1

Thimble Cover

7)

1

Wall Thimble (2 pcs.)

8)

1

Adapter

9)

1

AstroCap Termination Cap

10)

2

Trim Collars

11)

1

Tube of Mill-Pac, high temperature sealant

12)

12

Screws, #8 x 1/2" Self tapping, Stainless Steel

13)

14

Screws, #8 x 1/2" Self tapping, Black

14)4 Screws #8 x 1-1/2" Drill Point, Black

15) 4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

16) 8 Wood screws #8 x 1"

Note:

a)Liner sections should be con- tinuous without any joints or seams.

b)Thisisanapprovedsystem,there- fore components in this system must not be substituted for any other manufacturer's products.

DV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION

Review the following sequence of instructions which are typical of most installations. The se- quence may vary depending on wall thickness.

See the "Exterior Vent Terminal Locations" section for vent location and clearance dimensions, and "Vent Restrictor Position" section to set the Vent Restrictor to the correct position.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the venting system, adjust location until all clearances are met and there are no obstructions.

Note: A1-1/2"(38mm) clearance around the outerpipemustbemaintainedexcept that only a 1" (25mm) clearance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice buildup may occur. Be sure to check vent termina- tion area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

2)Assemble a trial fit to determine the vertical center-line for the vent termination.

a)Cut a 9-1/2" x 9-1/2" (241mm x 241

mm)square hole on both the interior and exterior wall.

b)Install wall thimbles on both interior and exterior wall with 4 wood screws (#8 x 1") per thimble.

c)Attach the 2 piece adjustable pipe sec- tion to the vent terminal and slide into position from the exterior. The larger diameter end of the adjustable pipe goes to the vent terminal.

d)Install the 90o elbow onto the adjust- able pipe to determine the vertical centerline.

Note:ifthecenterlinecannotbemet, the adjustable sections will have to be cut.

e)Cut the 4 ft. section of rigid pipe to length.Attach the 45o elbow to the rigid pipe, and ensure that the pipe length when cut (with the 45o elbow) will seat onto both the starter collar and the 90o elbow. Crimped section of rigid pipe seats into the 90o elbow. Only cut the uncrimped side of pipe.

Dismantle all pipe sections including vent terminal.

18

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Image 18
Contents H25 Direct Vent Gas Fireplace Unit Dimensions HamptonTo the New Owner Table of Contents Safety Label Copy of Safety Label for H25-NG1 & H25-LP1Requirements MA Code CO DetectorInstructions InstallationImportant Message Before YOU StartClearances to Combustibles General Safety InformationInstallation Checklist This includesManufactured Mobile Home Additional Requirements Optional FAN InstallationLocating Your GAS Stove Fan Kit ContainsInstallation Rotating 45O Elbow PrecautionsVent Restrictor Position Remove all 4 screws WashersExterior Vent Terminal Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsVenting Arrangements Dura-Vent Snorkel TerminationHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalDescription Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT Qty. DescriptionMust be used to ensure that the termination is not Planning Your venting Installation Minimum components for a Horizontal InstallationOptional Components DURA-VENT Venting Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Dura-Vent Basic Horizontal Kit #Minimum components for a Dura-Vent Verti- cal Termination Below Grade Snorkel InstallationHorizontal Terminations Snorkel TerminationsVertical Terminations Offset Chart Approved for US Installations Only Converting a Factory Built Metal ChimneyHigh Elevation Aeration AdjustmentCathedral Ceilings GAS ConnectionGAS Pipe Pressure Testing Valve DescriptionClockwise to open Counter-clockwise to close Conversion KIT #434-969 from NG to LP LPG Conversion Kit Contains QtyGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Lift off the Cast Top and remove the Glass Front see manual LOG SET InstallationShut off the gas supply Are fragile, handle with care do not force into positionLogs must be oriented as shown below On an interior wall Remote ControlWall Thermostat Rear View Decorative Door GrillWiring Diagrams Final CheckFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances Glass Replacement FAN MaintenanceLOG Replacement Replacement 946-327 GlassRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue ScrewsParts List Main AssemblyBurner & LOG Assembly Warranty ConditionsInstaller Please complete the following information