Hampton Direct H25-NG1, H25-LP1 Precautions, Vent Restrictor Position, Rotating 45O Elbow

Page 10

INSTALLATION

VENTING

INSTALLATION

SAFETY PRECAUTIONS

INTRODUCTION

PRECAUTIONS

FOR THE INSTALLER

The HorizontalTermination Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the Direct Vent Freestanding Gas Stoves, H25-NG1, and H25-LP1, have been tested and listed as direct vent heater systems by Warnock Hersey.

These units use the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combus- tion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be connected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.

The location of the termination cap must con- form to the requirements in the "Exterior Vent Terminal Locations" section.

These venting systems are engineered products that have been designed and tested for use with the H25-NG1, and H25-LP1. The warranty will be voided and serious fi re, health or other safety hazards may result from any of the fol- lowing actions:

1)Installation of any damaged Direct Vent component

2)Unauthorized modification of the Direct Vent System

3)Installation of any component part not manu- factured or approved by Simpson Dura-Vent or FPI Fireplace Products International Ltd.

4)Installation other than as instructed by Simp- son Dura-Vent and FPI Fireplace Products International Ltd.

Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.

Be sure to check the vent termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specifi ed in the "Exterior Vent Terminal Locations" section and in your local building codes.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appli- ance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

1)Wear gloves and safety glasses for protec- tion.

2)Exercise extreme caution when using lad- ders or on roof tops.

3)Be aware of electrical wiring locations in walls and ceilings.

VENT RESTRICTOR

POSITION

To set the Vent restriction as indicated in the diagrams in "Venting Arrangements" section, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws.

1)Remove all 4 screws that secure the elbow to the unit using a 1/4" magnetic nut driver.

Remove all 4 screws

and washers

ROTATING 45O ELBOW

2)Rotate the elbow 180o

3)Secure the elbow by securing it with the 4 screws.

10

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Image 10
Contents H25 Direct Vent Gas Fireplace Hampton Unit DimensionsTo the New Owner Table of Contents Safety Label Copy of Safety Label for H25-NG1 & H25-LP1Requirements MA Code CO DetectorInstructions InstallationImportant Message Before YOU StartClearances to Combustibles General Safety InformationInstallation Checklist This includesManufactured Mobile Home Additional Requirements Optional FAN InstallationLocating Your GAS Stove Fan Kit ContainsInstallation Rotating 45O Elbow PrecautionsVent Restrictor Position Remove all 4 screws WashersExterior Vent Terminal Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsVenting Arrangements Dura-Vent Snorkel TerminationHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalDescription Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT Qty. DescriptionMust be used to ensure that the termination is not Minimum components for a Horizontal Installation Planning Your venting InstallationOptional Components DURA-VENT Venting Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Dura-Vent Basic Horizontal Kit #Minimum components for a Dura-Vent Verti- cal Termination Below Grade Snorkel InstallationHorizontal Terminations Snorkel TerminationsVertical Terminations Offset Chart Approved for US Installations Only Converting a Factory Built Metal ChimneyHigh Elevation Aeration AdjustmentCathedral Ceilings GAS ConnectionValve Description GAS Pipe Pressure TestingClockwise to open Counter-clockwise to close Conversion KIT #434-969 from NG to LP LPG Conversion Kit Contains QtyGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Lift off the Cast Top and remove the Glass Front see manual LOG SET InstallationShut off the gas supply Are fragile, handle with care do not force into positionLogs must be oriented as shown below On an interior wall Remote ControlWall Thermostat Rear View Decorative Door GrillWiring Diagrams Final CheckFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances Glass Replacement FAN MaintenanceLOG Replacement Replacement 946-327 GlassRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue ScrewsParts List Main AssemblyBurner & LOG Assembly Warranty ConditionsInstaller Please complete the following information