Hampton Direct H25-LP1, H25-NG1 installation manual Installation

Page 9

INSTALLATION

9)Place the blower close to the base of the unit and feed the long red and black wires through the opening of the base of the unit and connect them to the thermodisc.

12)Before re-attaching the rear access panel, the valve wires and the fan wires need to be connected.

Re-connect the red and grey valve wires.

Connect the fan wires.

10)Feed the short red and black wires through the small hole at the base of the unit.

11)Mount the blower assembly in position under the base of the stove and secure with the 2 supplied bolts (2-1/4" #20 hex head)

13)Slide the Rear Access Panel back into position and secure with 2 screws.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Hampton® H25-1 Direct Vent Freestanding Gas Stove

9

Image 9
Contents H25 Direct Vent Gas Fireplace Unit Dimensions HamptonTo the New Owner Table of Contents Copy of Safety Label for H25-NG1 & H25-LP1 Safety LabelMA Code CO Detector RequirementsImportant Message InstallationInstructions Before YOU StartInstallation Checklist General Safety InformationClearances to Combustibles This includesLocating Your GAS Stove Optional FAN InstallationManufactured Mobile Home Additional Requirements Fan Kit ContainsInstallation Vent Restrictor Position PrecautionsRotating 45O Elbow Remove all 4 screws WashersExterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsHorizontal CapsDura-Vent Snorkel Termination Venting Arrangements+ H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsStraight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemDescription Alternate Approved CapsQty. Description DV Stove Horizontal Vent KITMust be used to ensure that the termination is not Planning Your venting Installation Minimum components for a Horizontal InstallationOptional Components DURA-VENT Termination KIT Planning Your Dura-Vent InstallationDURA-VENT Venting Dura-Vent Basic Horizontal Kit #Horizontal Terminations Below Grade Snorkel InstallationMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsVertical Terminations Offset Chart Converting a Factory Built Metal Chimney Approved for US Installations OnlyCathedral Ceilings Aeration AdjustmentHigh Elevation GAS ConnectionGAS Pipe Pressure Testing Valve DescriptionClockwise to open Counter-clockwise to close LPG Conversion Kit Contains Qty Conversion KIT #434-969 from NG to LPGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Shut off the gas supply LOG SET InstallationLift off the Cast Top and remove the Glass Front see manual Are fragile, handle with care do not force into positionLogs must be oriented as shown below Wall Thermostat Remote ControlOn an interior wall Rear View Decorative Door GrillFinal Check Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingMaintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances LOG Replacement FAN MaintenanceGlass Replacement Replacement 946-327 GlassTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve ScrewsMain Assembly Parts ListBurner & LOG Assembly Conditions WarrantyInstaller Please complete the following information