Hampton Direct H25-LP1, H25-NG1 Must be used to ensure that the termination is not

Page 19

INSTALLATION

3)Attach the 4" dia. fl ex liner to the vent ter- minal ensuring that the fl ex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stainless steel).

4)Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel).

Hint: Apply the sealant (Mill-Pac and/or high temperature silicone) to the outer pipe before connecting the inner pipe.

Note: The pipe

s e a m

s h o u l d be facing

down.

Note: To make the installation more aes- thetically pleasing, we recommend framing out a square that the cap can be mounted on.

Note: If installing ter- mination on a siding covered

wall, a vinyl sid-

ing standoff or furring strips

must be used to ensure that the termination is not

recessed into the siding. For vinyl siding standoff installation refer to the Dura-Vent Termination instruc- tions.

5)Slide the partially connected pipe and vent terminal assembly through the wall thimbles (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill point, stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 4 corners.

Note: The four screws provided for the vent cap should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

6)A bead of non-hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff.

7)Stretch the 4" dia. fl ex liner out fully and get a trial fi t of the liner onto the 4" dia. starter collar.

8)Cut the 4" dia. fl ex liner to the desired size.

Hint: leave an extra 12" to 16" of length, this will make the fi nal assembly easier to work with.

9)Secure the 4" dia. flex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel).

10)Slide the decorative Thimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2" drill point, black) to the wall.

11)Slide the 90o elbow (crimp end up), the 45o elbow and the 4 ft. pipe section (crimp end up) over the 4" dia. fl ex liner.

12)Install the spring spacers onto the pipe sections.

13)Secure the 4" dia. fl ex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel).

14)Attach the 45o elbow onto the starter col- lar by sealing with Mill-Pac and/or high temperature silicone and securing with 3 of the #8 x 1/2" (black) screws.

15)Attach the pipe section to the 45o elbow by sealing with Mill-Pac and/or high tempera- ture silicone and securing with 3 of the #8 x 1/2" screws (black). Pipe seams should be facing the wall.

16)Attach the 90o elbow onto the pipe section by sealing with Mill-Pac and/or high tem- perature silicone and securing with 3 of the #8 x 1/2" screws (black).

17)Slide the adjustable pipe section onto the 90o elbow. Slide the trim collar over the adjustable pipe sections to cover the joint of the telescopic section.) The fl ex may have to be compressed back in order for the adjustable pipe to properly mate to the elbow. Seal with Mill-Pac and/or high temperature silicone and secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down.

18)Install the trim collar over the starter col- lar and secure with a #8 x 1/2" screw (black).

If the pipe needs to be touched up, use only Stove Brite High Temperature Metallic Black Stove Paint.

NOTE: All inner joints must be sealed with Mill-Pac.Allouterjointsmaybesealed with high temperature silicone.

Hampton® H25-1 Direct Vent Freestanding Gas Stove

19

Image 19
Contents H25 Direct Vent Gas Fireplace Hampton Unit DimensionsTo the New Owner Table of Contents Copy of Safety Label for H25-NG1 & H25-LP1 Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationImportant Message InstructionsThis includes General Safety InformationInstallation Checklist Clearances to CombustiblesFan Kit Contains Optional FAN InstallationLocating Your GAS Stove Manufactured Mobile Home Additional RequirementsInstallation Remove all 4 screws Washers PrecautionsVent Restrictor Position Rotating 45O ElbowExterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListCaps Rigid Pipe Venting SystemsAlternate HorizontalDura-Vent Snorkel Termination Venting Arrangements+ H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsAlternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations DescriptionQty. Description DV Stove Horizontal Vent KITMust be used to ensure that the termination is not Minimum components for a Horizontal Installation Planning Your venting InstallationOptional Components Dura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT VentingSnorkel Terminations Below Grade Snorkel InstallationHorizontal Terminations Minimum components for a Dura-Vent Verti- cal TerminationVertical Terminations Offset Chart Converting a Factory Built Metal Chimney Approved for US Installations OnlyGAS Connection Aeration AdjustmentCathedral Ceilings High ElevationValve Description GAS Pipe Pressure TestingClockwise to open Counter-clockwise to close LPG Conversion Kit Contains Qty Conversion KIT #434-969 from NG to LPGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Are fragile, handle with care do not force into position LOG SET InstallationShut off the gas supply Lift off the Cast Top and remove the Glass Front see manualLogs must be oriented as shown below Rear View Decorative Door Grill Remote ControlWall Thermostat On an interior wallFinal Check Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingMaintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances Replacement 946-327 Glass FAN MaintenanceLOG Replacement Glass ReplacementScrews Installing Valve AssemblyTo remove valve from valve assembly, continue Removing ValveMain Assembly Parts ListBurner & LOG Assembly Conditions WarrantyInstaller Please complete the following information