INSTALLATION

LOG SET INSTALLATION

Read the instructions below carefully and refer to the diagrams. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)Rear Log

b)Left Side Front Log

c)Right Side Front Log

d)Center Front Log

e) Embers

902-156

A)

B)

C)

1)

Shut off the gas supply.

2)

Lift off the Cast Top and remove the Glass Front (see manual).

3)

Carefully remove the logs from the box and unwrap them. The logs

 

are fragile, handle with care - do not force into position.

4)

Place the rear log on the 2 rear log locating pins on the rear of the

 

burner with the fl at side to the back.

5)Place the 2 front logs on the front log locating pins. Ensure the back of both logs rest against the tabs.

B)

Left Front Log

NOTE: This is

 

a rear view.

B)

 

Tabs

A)

Right Front Log

A)

The Front Right Log front edges should be placed parallel against the front edge of the burner.

C)

B)

C)

NOTE: This is

a rear view.

C)

Tabs

Hampton® H25-1 Direct Vent Freestanding Gas Stove

31

Image 31
Contents H25 Direct Vent Gas Fireplace Hampton Unit DimensionsTo the New Owner Table of Contents Copy of Safety Label for H25-NG1 & H25-LP1 Safety LabelMA Code CO Detector RequirementsBefore YOU Start InstallationImportant Message InstructionsThis includes General Safety InformationInstallation Checklist Clearances to CombustiblesFan Kit Contains Optional FAN InstallationLocating Your GAS Stove Manufactured Mobile Home Additional RequirementsInstallation Remove all 4 screws Washers PrecautionsVent Restrictor Position Rotating 45O ElbowExterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListCaps Rigid Pipe Venting SystemsAlternate HorizontalDura-Vent Snorkel Termination Venting Arrangements+ H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsAlternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations DescriptionQty. Description DV Stove Horizontal Vent KITMust be used to ensure that the termination is not Minimum components for a Horizontal Installation Planning Your venting InstallationOptional Components Dura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT VentingSnorkel Terminations Below Grade Snorkel InstallationHorizontal Terminations Minimum components for a Dura-Vent Verti- cal TerminationVertical Terminations Offset Chart Converting a Factory Built Metal Chimney Approved for US Installations OnlyGAS Connection Aeration AdjustmentCathedral Ceilings High ElevationValve Description GAS Pipe Pressure TestingClockwise to open Counter-clockwise to close LPG Conversion Kit Contains Qty Conversion KIT #434-969 from NG to LPGlow on logs Installation of the DC Sparker for the H25-1 Unit Only Are fragile, handle with care do not force into position LOG SET InstallationShut off the gas supply Lift off the Cast Top and remove the Glass Front see manualLogs must be oriented as shown below Rear View Decorative Door Grill Remote ControlWall Thermostat On an interior wallFinal Check Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Read Before LightingMaintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances Replacement 946-327 Glass FAN MaintenanceLOG Replacement Glass ReplacementScrews Installing Valve AssemblyTo remove valve from valve assembly, continue Removing ValveMain Assembly Parts ListBurner & LOG Assembly Conditions WarrantyInstaller Please complete the following information