Hampton Direct H25-NG1, H25-LP1 Removing Valve, Installing Valve Assembly, Screws

Page 40

MAINTENANCE

3)Unclip the black and white wires from the fan motor.

4)Remove the 2 bolts holding the fan to the rear base. Disconnect the green ground wire from the right side of the fan as soon as you can reach it.

Replacing the Fan:

Reverse the above steps (1 - 4). Make sure the fan wires and the ground wire are reat-

6)Disconnect piezo wire.

7)Lift off the Cast Top and lift out the front door.

8) Carefully remove the logs and embers.

9)Remove burner by removing the 2 screws on each side and then lifting the burner tray out.

Screws

Note: Use a magnetic type screwdriver if possible.

12)To remove the valve, remove the 4 screws (2 per bracket) that hold the valve to the valve bracket assembly.

13)To replace the burner tray assembly, simply reverse these instructions.

To remove valve from valve assembly, continue.

14)

Remove two (2) thermopile wires.

15)

Remove thermocouple with a 9 mm (metric)

 

wrench.

16)

Remove pilot nut with an 11 mm wrench.

17)

Remove valve to orifi ce nut with a 13/16"

 

wrench.

18)

Remove inlet pipe with pipe wrench. Note

 

orientation of 90o elbow.

19)

Remove two (2) phillips head M5 screws on

 

each side of the valve.

REMOVING VALVE

If your valve requires maintenance or replace- ment, use the following instructions:

Note: Alwayscloseoffthegassupplybefore removing the valve.

1)If optional fan is installed, disconnect power source to stove.

2)Remove access panel.

3)Disconnect gas line to stove.

4)Disconnect 3/8" NPT pipe from 90o elbow on valve or fl ex connector.

5)Disconnect the two (2) switch wires from valve.

10)Remove all 6 screws holding the burner tray assembly in place.

11)Carefully lift the burner tray assembly out.

20) Remove valve and remove gas out 90o brass

fi tting. Note orientation of fi tting.

INSTALLING

VALVE ASSEMBLY

1)To install a new valve assembly, reverse instructions for removing valve. See as- sembly steps 1-12.

2)Check for leaks and manifold pressure. See Gas Pressure Test instructions.

3)To reinstall valve, reverse instructions for removing valve assembly, steps 13-19.

40

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Image 40
Contents H25 Direct Vent Gas Fireplace Hampton Unit DimensionsTo the New Owner Table of Contents Safety Label Copy of Safety Label for H25-NG1 & H25-LP1Requirements MA Code CO DetectorInstallation Important MessageInstructions Before YOU StartGeneral Safety Information Installation ChecklistClearances to Combustibles This includesOptional FAN Installation Locating Your GAS StoveManufactured Mobile Home Additional Requirements Fan Kit ContainsInstallation Precautions Vent Restrictor PositionRotating 45O Elbow Remove all 4 screws WashersExterior Vent Terminal Locations Rigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Systems AlternateHorizontal CapsVenting Arrangements Dura-Vent Snorkel TerminationHorizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalVertical Termination with CO-LINEAR Flex System Straight Vertical TerminationsDescription Alternate Approved CapsDV Stove Horizontal Vent KIT Qty. DescriptionMust be used to ensure that the termination is not Minimum components for a Horizontal Installation Planning Your venting InstallationOptional Components Planning Your Dura-Vent Installation DURA-VENT Termination KITDURA-VENT Venting Dura-Vent Basic Horizontal Kit #Below Grade Snorkel Installation Horizontal TerminationsMinimum components for a Dura-Vent Verti- cal Termination Snorkel TerminationsVertical Terminations Offset Chart Approved for US Installations Only Converting a Factory Built Metal ChimneyAeration Adjustment Cathedral CeilingsHigh Elevation GAS ConnectionValve Description GAS Pipe Pressure TestingClockwise to open Counter-clockwise to close Conversion KIT #434-969 from NG to LP LPG Conversion Kit Contains QtyGlow on logs Installation of the DC Sparker for the H25-1 Unit Only LOG SET Installation Shut off the gas supplyLift off the Cast Top and remove the Glass Front see manual Are fragile, handle with care do not force into positionLogs must be oriented as shown below Remote Control Wall ThermostatOn an interior wall Rear View Decorative Door GrillWiring Diagrams Final CheckFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances FAN Maintenance LOG ReplacementGlass Replacement Replacement 946-327 GlassInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve ScrewsParts List Main AssemblyBurner & LOG Assembly Warranty ConditionsInstaller Please complete the following information