INSTALLATION
To adjust the aeration: use the allen key to turn the turning gear which will adjust the air shutter. Open the air shutter for a blue fl ame or close it for a more yellow fl ame. This adjustment is per- formed by a qualified installer.The factory setting should be suffi cient for most installations.
Clockwise to open,
counter-clockwise to close.
Caution: Carbon will be produced if the air shutter is closed too much.
Note: Any damage due to carboning re- sulting from improperly setting the aeration controls is NOT covered under warranty.
Note: Aeration Adjustment should only be performed by an authorized Hamp- ton® Installeratthetimeofinstallation or service.
GAS PIPE
PRESSURE TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual
The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1)Make sure the valve is in the "OFF" posi- tion.
2)Loosenthe"IN"and/or"OUT"pressuretap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.
3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.
4)Light the pilot and turn the valve to "ON" position. Read manometer.
5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.
6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten
Valve Description
1)Gas on/off knob
2)Manual high/low adjustment
3)Pilot Adjustment
4)Thermocouple Connection
5)Main Operator
6)Outlet Pressure Tap (Manifold Pressure)
7)Inlet Pressure Tap (Supply Pressure)
8)Pilot Outlet
9)Main Gas Outlet
10)Flange Securing Screw Holes
11)Alternative TC Connection Point
12)Thermoelectric Unit
13)Additional Valve Mounting Hole
Hampton® | 27 |