Patterson-Kelley MOD-04 owner manual Modu-FireGas-Fired Boiler, Introduction/Safety

Page 4

Modu-Fire®Gas-Fired Boiler

1.0 INTRODUCTION

The P-K MODU-FIRE®Gas Fired Boiler is a revo- lutionary advance; Patterson-Kelley now combines full-modulation burner control with our time-tested modular hot water boiler design. The result is “modular full-modulation”- Modu-Fire! This new hybrid boiler combines the best of our earlier de- signs with a new generation of burner and control technology. You will achieve even higher part-load efficiencies – but without the complexity you might expect in this type of high performance boiler. High performance made simple and dependable for years of trouble-free operation.

This manual covers installation of the P-K MODU- FIRE® Boiler Series 1000, 1500, and 2000. The model numbers may be followed by a prefix or suf- fix letter in some cases to indicate special features or different options. While details may differ slightly, basic operation is the same for all models. Boilers are built to operate with natural gas or pro- pane. Check the rating plate for the correct gas type and flow rate.

The boiler is only a part of the complete heating system. This boiler may be fully operational and yet because of poor circulation, controls, or other oper- ating characteristics, not deliver heat to the desired location. Additional equipment such as temperature sensors, pumps, flow switches, balancing valves and check valves will be required for satisfactory opera- tion of any system. Patterson-Kelley cannot be re- sponsible for the design or operation of such sys- tems and a qualified engineer or contractor must be consulted.

2.0SAFETY

2.1GENERAL

The MODU-FIRE®gas-fired boiler must be:

Installed in accordance with designs prepared by qualified facility engineers including: struc- tural, mechanical, electrical, and other applica- ble disciplines.

Introduction/Safety

Operated and serviced in accordance with a comprehensive safety program determined and established by the customer. Do not attempt to operate or service until such a program has been established.

Operated and serviced by qualified, factory- trained personnel in accordance with all appli- cable codes, laws, and regulations.

The use of the term “factory-trained personnel” throughout this manual indicates Patterson- Kelley trained on this specific piece of equip- ment.

2.2TRAINING

!WARNING

Improper use may result in fire or injury.

Read instructions/safety manual before installing, operating or servicing boiler.

c 1998 HCS, Inc. 800-748-0241

Reorder No. 6020-V2WHPK

It is essential to read, understand, and follow the recommendations of this manual before installing, operating, or servicing this equipment. Failure to do so could result in serious injury, death, and/or prop- erty damage.

Proper training is the best protection against acci- dents. Operating and service personnel must be thoroughly familiar with the basic construction of the MODU-FIRE®boiler, the use and locations of the controls, the operation of the boiler, adjustment of its various mechanisms, and all applicable safety precautions. If any of the provisions of this manual are not fully and completely understood, contact the Patterson-Kelley Sales Department.

2.3SAFETY FEATURES

It is the responsibility of the customer to maintain the safety features of this machine, such as: guards, safety labels, safety controls, interlocks, lockout devices, etc., in place and operable.

1

Image 4
Contents PATTERSON-KELLEY Modu-FireGas-Fired Boiler Table of Contents What to do if you smell gas Introduction/Safety Modu-FireGas-Fired BoilerElectrical Hazards SafetyBurn, Fire, and Explosion Hazards Crush Hazards Modu-FireGas-Fired Boiler SafetyChemical Hazards Modu-FireGas-Fired Boiler Safety Pressure Hazards Slip, Fall HazardsStorage Prior to Installation InstallationPlacement Initial InspectionModu-FireGas-Fired Boiler Installation ClearancesCombustion AIR Vent Elbows Barometric DamperAutomatic Vent Damper Flue ConnectionRemoving an Existing Boiler Pipe Capacity for Natural Gas Gas Bleeds and Vents by Installer Modu-FireGas-Fired Boiler Gas Supply Piping by InstallerPiping Design Boiler Water Piping by Installer Boiler Inlet and Outlet ConnectionsWater Quality Flushing and FillingInspection Test of Low Water Cut-off Test of Ignition Safety SystemTest of Limit Controls Test of High Gas Pressure Switch Test of Low Gas Pressure Switch12.1A Configuring the Local Controller For example, assume the following settings Configuration level Is pressed Table of Parameters 12.1B Optional Remote Control Installation Air Flow AdjustmentsBasic Combustion Adjustment Procedure Modu-FireGas-Fired Boiler Operation Lighting ProceduresControl Panel Front Normal Shut Down Procedures Emergency Shut OffMaintenance Weekly DailyMonthly During Operation Semi-AnnuallyMaintenance AnnuallyPilot Tube Ceramic Spider Ignition Electrode Standard Modulating Modu-FireGas-Fired Boiler Maintenance IRI ModulatingLoss of Power Do not Table of Contents for this Section Parts/Technical SupportCustomer Connections Customer Customer Input Analog Connections Customer Alarm Safety Flame Interlock Start 2 # Interlock Start 1 # Alarm Safety Flame Interlock Start 2 # Interlock Start 1 # Customer Connections Page Page Main Assembly Part Modu-Fire Gas-Fired Boiler Parts/Technical SupportLocal Control Panel Modu-FireGas-Fired Boiler Parts/Technical Support Modu-FireGas-Fired Boiler Parts/Technical Support Gas Trains No.PartStandard Gas Train 1500 IRI Gas Train IRI Gas Train 1500 Modu-FireGas-Fired Boiler Parts/Technical Support Cabinet No. PartLimited Warranty Limited WarrantyMODU-FIREBOILER