Patterson-Kelley MOD-04 owner manual Modu-FireGas-Fired Boiler Parts/Technical Support

Page 47

 

 

Modu-Fire®Gas-Fired Boiler

 

 

Parts/Technical Support

 

 

 

 

 

 

 

 

 

 

 

 

Circuit Breaker

Relays and

 

 

 

 

Sockets

1

4

 

 

 

 

2

7, 7a, 7b, 8

6

9

Forced Recycle Time

3

12

5

11

Delay Relay

 

 

 

 

Remote Control Panel

No.

Part

No.

Part

No.

Part

1.

Thermostat (Manual

Re-

7.

Flame Safeguard

Pro-

10a.

Ignition Cable (not

visi-

 

set)

 

grammer

 

ble)

2.

Thermostat (Oper. Temp)

7a.

Amplifier (UV Scanner)

11.

Indicator Light, Red

3.

Air Flow Switch

7b.

Timing Card, 30 sec.

12.

Indicator Light, Green

4.

Motor Start Relay

8.

Programmer, Sub-Base

 

 

 

5.

Terminal Block, Neutral

9.

Switch, On/Off, Lighted

 

 

 

6.

Terminal Block, Power

10.

Ignition Transformer (not

 

 

 

 

 

 

 

visible)

 

 

 

44

Image 47
Contents PATTERSON-KELLEY Modu-FireGas-Fired Boiler Table of Contents What to do if you smell gas Modu-FireGas-Fired Boiler Introduction/SafetyBurn, Fire, and Explosion Hazards SafetyElectrical Hazards Chemical Hazards Modu-FireGas-Fired Boiler SafetyCrush Hazards Slip, Fall Hazards Modu-FireGas-Fired Boiler Safety Pressure HazardsInitial Inspection Storage Prior to InstallationInstallation PlacementClearances Modu-FireGas-Fired Boiler InstallationCombustion AIR Flue Connection Vent ElbowsBarometric Damper Automatic Vent DamperRemoving an Existing Boiler Pipe Capacity for Natural Gas Piping Design Modu-FireGas-Fired Boiler Gas Supply Piping by InstallerGas Bleeds and Vents by Installer Boiler Inlet and Outlet Connections Boiler Water Piping by InstallerInspection Flushing and FillingWater Quality Test of Limit Controls Test of Ignition Safety SystemTest of Low Water Cut-off 12.1A Configuring the Local Controller Test of Low Gas Pressure SwitchTest of High Gas Pressure Switch For example, assume the following settings Configuration level Is pressed Table of Parameters Installation Air Flow Adjustments 12.1B Optional Remote ControlBasic Combustion Adjustment Procedure Control Panel Front Lighting ProceduresModu-FireGas-Fired Boiler Operation Emergency Shut Off Normal Shut Down ProceduresSemi-Annually Maintenance WeeklyDaily Monthly During OperationAnnually MaintenancePilot Tube Ceramic Spider Ignition Electrode Standard Modulating IRI Modulating Modu-FireGas-Fired Boiler MaintenanceLoss of Power Do not Parts/Technical Support Table of Contents for this SectionCustomer Connections Customer Customer Input Analog Connections Customer Alarm Safety Flame Interlock Start 2 # Interlock Start 1 # Alarm Safety Flame Interlock Start 2 # Interlock Start 1 # Customer Connections Page Page Modu-Fire Gas-Fired Boiler Parts/Technical Support Main Assembly PartLocal Control Panel Modu-FireGas-Fired Boiler Parts/Technical Support No.Part Modu-FireGas-Fired Boiler Parts/Technical Support Gas TrainsStandard Gas Train 1500 IRI Gas Train IRI Gas Train 1500 No. Part Modu-FireGas-Fired Boiler Parts/Technical Support CabinetLimited Warranty Limited WarrantyMODU-FIREBOILER