| Function • Funcionamiento |
|
| english | ||||
| Fonctionnement • Funcionamento |
| |||||||
|
|
| |||||||
1 |
|
|
|
|
|
| The condensate flows through the feed | ||
|
|
|
|
|
|
| line (1) into the BEKOMAT unit and | ||
|
|
|
|
|
|
| accumulates in the container (2). A | ||
|
|
|
|
|
|
| capacitive sensor (3) continuously re- | ||
|
|
|
|
|
|
| gisters the liquid level and passes a | ||
|
|
|
|
|
|
| signal to the electronic control as | ||
|
|
|
|
|
|
| soon as the container is filled. The | ||
|
|
|
|
|
| 4 | pilot valve (4) is then activated and the | ||
|
|
|
|
|
|
| diaphragm (5) opens the outlet line | ||
|
|
|
|
|
|
| (6) for discharging the condensate. | ||
|
|
|
|
|
|
| When the BEKOMAT unit has been | ||
|
|
|
|
|
|
| emptied, the outlet line is closed | ||
2 | 3 |
|
|
| 5 | 6 | again quickly and tightly without wa- | ||
|
|
| sting compressed air. | ||||||
|
|
|
|
|
|
| |||
|
|
| BEKOMAT 21 |
|
| The operating states of the BEKOMAT | |||
|
|
|
|
|
|
| 21 are indicated by one LED with dif- | ||
Power |
| 1 | Power |
| ferent flashing frequencies. | ||||
|
| TEST | 2 |
|
| TEST | 1 | Ready for operation | |
|
|
|
| Power on | |||||
Valve | Alarm |
| 3 | Valve | Alarm |
| 2 | Discharge procedure | |
|
|
|
| ||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| Outlet line open | |
|
| BEKOMAT 21 PRO |
| If the condensate discharge is not func- | |||||
|
|
| tioning properly, the valve will keep | ||||||
|
|
|
|
|
|
| opening (about every 3 seconds) so as | ||
Alarm |
|
| Alarm |
|
| to clear the fault automatically, if | |||
Valve | TEST |
| Valve |
| TEST | possible. | |||
|
|
| Malfunction /Alarm | ||||||
Power |
| 1 | Power |
| 2 | 3 | |||
|
|
| |||||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| 4 | Test of valve function and | |
Alarm |
|
|
|
|
| manual drainage: briefly press | |||
|
| Alarm |
|
|
| button. | |||
Valve | TEST |
| Valve |
| TEST | Additional feature of the BEKOMAT 21 | |||
|
|
| 3 |
| 4 | ||||
Power |
| Power |
| PRO: press button for > 1 minute to | |||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| test the alarm function (s. below). | ||
Switching sequence of valve in alarm mode |
|
| The BEKOMAT 21 PRO also has an | ||||||
Secuencia de apertura de la válvula en el modo de alarma. |
| ||||||||
Séquence d'activation de la vanne en modeAlarme | 7,5 sec | If normal conditions have not been re- | |||||||
stored after 1 minute, a fault signal | |||||||||
Sequência de ligação da válvula no modo de alarme | |||||||||
> < | will be triggered: | ||||||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| • Alarm LED flashes. | ||
|
|
|
|
|
|
| • Alarm signal switches over (can be | ||
|
|
|
|
|
|
| transmitted via | ||
|
|
|
|
|
|
| tact). | ||
|
|
|
|
|
|
| • Valve opens every 4 minutes for a | ||
|
|
|
|
|
|
| period of 7.5 seconds. | ||
|
|
|
|
|
|
| Once the fault is cleared, the | ||
< 1 min >< | 3 min | >< 4 min | >< | 4 min | > | BEKOMAT 21 PRO will automatically | |||
switch back to the normal mode of | |||||||||
|
|
|
|
|
|
| operation. | ||
|
|
|
|
|
|
| Malfunctioning could be caused | ||
|
|
|
|
|
|
| by, e.g.: | ||
|
|
|
|
|
|
| • Mistakes during installation | ||
|
|
|
|
|
|
| • Dropping below the necessary mi- | ||
Alarm signal via | nimum pressure | ||||||||
Mensaje de alarma a través de contacto sin potencial (solamente BEKOMAT 21 | • Excessive condensate quantities | ||||||||
PRO) |
|
|
|
|
|
| |||
|
|
|
|
|
| • Blocked/shut off outlet line | |||
Signal d'alarme délivré sur le contact sans potentiel(uniqu. BEKOMAT 21 PRO) | |||||||||
• Extreme amount of dirt particles | |||||||||
Sinal de alarme via contacto isento de potência (só BEKOMAT 21 PRO) | |||||||||
• Frozen piping | |||||||||
|
|
|
|
|
|
|
4 | BEKOMAT 21, 21 PRO |