Leupold 21 PRO manual „Test

Page 14

 

Trouble shooting • Búsqueda de fallos

english

 

Recherche de panne • Localização de avarias

 

 

Power

No LED lighting up

Possible causes:

 

 

 

TEST

Ningún LED está iluminado

• Power supply faulty

 

• Power supply board defective

 

 

 

Valve

Alarm

Aucune LED n'est allumée

• Control PCB defective

 

 

- Check voltage on type plate.

 

 

Todos os LEDs apagados

 

 

- Check wiring (external and internal)

Alarm

 

 

- Check plug connections

Valve

TEST

 

- Check printed circuit boards for

 

possible damage

Power

 

 

 

 

 

 

 

 

 

Power

Pressing of test button, but no

Possible causes:

condensate discharge

• Feed and/or outlet line shut off or

 

 

 

TEST

 

 

El interruptor de „TEST“ está

blocked

 

 

• Worn parts (seals, valve core,

Valve

Alarm

pulsado, pero el condensado no

diaphragm)

 

 

se evacua

 

 

• Control PCB defective

 

 

 

 

 

La touche Test est actionnée,

• Solenoid valve defective

Alarm

 

• Dropping below necessary minimum

 

mais sans purge du condensat

 

pressure

Valve

TEST

 

Botão de teste premido, mas não

- Check feed line and outlet line

Power

 

 

há descarga de condensado

- Replace worn parts

 

 

 

 

 

- Check if valve opens audibly (press

 

 

 

test button several times)

 

 

 

- Check printed circuit boards for

 

 

 

possible damage

 

 

 

- Check operating pressure; where

 

 

 

necessary, install pressure or

 

 

 

vacuum drains.

Power

 

Condensate discharge only when

Possible causes:

 

test button is being pressed

• Feed line with insufficient slope;

 

 

 

 

 

 

TEST

Evacuación del condensado soló

crosssection too small.

 

 

 

• Excessive condensate quantities

Valve

Alarm

 

si está pulsado el interruptor de

 

• Sensor tube extremely dirty

 

 

 

„TEST“

 

 

 

- Lay feed line with adequate slope

 

 

 

 

Alarm

 

 

Purge du condensat uniquement si

- Install venting line

 

 

la touche Test est actionnée

- Clean sensor tube

Valve

 

TEST

 

 

 

Power

 

 

Descarga de condensado só com

 

 

 

 

o botão de teste premido

 

Power

 

 

Device keeps blowing off air

Possible causes:

 

 

 

• Control air line blocked

 

 

 

El aparato está abierto

 

 

TEST

• Worn parts (seals, valve core,

 

 

constantemente

 

Alarm

 

diaphragm)

Valve

 

 

 

L'appareil refoule de l'air en

 

 

 

 

- Clean entire valve unit

 

 

 

permanence

- Replace worn parts

Alarm

 

 

O purgador perde ar

- Clean sensor tube

 

 

 

 

 

 

 

Valve

 

TEST

continuamente

 

Power

 

 

 

 

14

BEKOMAT 21, 21 PRO

Image 14
Contents Bekomat Bekomat 21 PRO English Español Français PortuguêsCom óleo + isento de óleo Carcasa Material plástico, reforçado por fibra de vidroSó utilizar material de instalação resistente à pressão Do not operate the de- vice when there is a danger of frostEjecute la instalación eléctrica según las normas vigentes By, e.g Alarm-mode functionMalfunctioning could be caused Español Français Português Modo de alarmeModo de alarma Sibles São, p.exInstallation Instalación Installation Instalação English Wrong no correcto Correct correcto Incorrect incorrectoTubagem Bekomat Affectation des bornes Asignación de los bornesOcupação dos bornes Assembly Connect power supplyPotential-free alarm contact KL2.3-2 N.C.-COM KL2.1-2 N.O.-COMBekomat 21 PRO KL4Bekomat Bekomat 21 PRO Controlar o sinal de alarme En mode fail-safeVérification du signal dalarme Modo fail-safe„TEST Posibles causasosibles causas Español Français Posibles causas Origines possiblesPortuguês Causas possíveis Components Despieze Nomenclature des pièces Componentes English Español Français Português Electronic PCB 230 Vac Electronic PCB 110 VacBekomat 21, 21 PRO Dimensions Dimensiones Dimensions Dimensões Bekomat 21, 21 PRO Bekomat 21, 21 PRO Bekomat 21, 21 PRO Clearpoint