| Step 18: Photoelectric Safety Sensor Installation |
|
|
| WALL |
|
|
| ||||
|
|
|
| MOUNTING |
|
|
| |||||
|
|
|
|
|
|
|
|
| BRACKET |
|
|
|
| Select a mounting position 5 inches above the floor |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
| to center line of wall mounting bracket. The send- |
|
|
|
|
|
|
|
|
|
|
|
| ing and receiving units should be mounted inside the |
|
|
|
|
|
|
|
|
|
|
|
| door opening to minimize any interference by the sun. |
|
|
|
|
|
|
|
|
|
|
|
| However, the sensors should be mounted as close to the |
|
|
|
|
|
|
|
|
|
|
|
| door track or inside edge of the door as possible to offer |
|
|
|
|
|
|
| “U” |
|
|
|
| maximum entrapment protection. It is very important |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| BRACKET |
| |||
| that both wall brackets be mounted at the same height |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| for proper alignment. |
|
|
|
| (1) 5/16 X | NAIL |
| ||||
|
|
|
|
|
|
| ||||||
| The brackets may be temporarily mounted to the jamb |
|
|
|
| LAG SCREWS |
| |||||
| with a 1” flat head nail (provided) using the small hole |
|
|
|
|
|
|
|
|
|
|
|
| above the slot. Using two 5/16 x |
|
|
| NUT |
|
|
|
|
|
|
|
| vided), permanently mount the wall mounting brackets |
|
|
| WASHER |
|
|
| ||||
| to both door jambs. In some installations it may be nec- |
|
|
|
|
|
| |||||
| essary to attach a wooden spacer to the wall to achieve |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5” |
| |||
| the required clearance. |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
| Attach the “U” brackets to the wall brackets with a |
|
|
|
|
|
|
| ||||
|
|
|
|
| CARRIAGE BOLT |
|
|
| ||||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| |
| sert |
|
|
|
|
|
|
|
|
|
|
|
| the bolt from the inside of the “U” bracket and hand |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| tighten only at this time. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RECEIVING UNIT |
|
|
| |||||
| Identify which side of the garage door opening (if any) |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
| is “likely” to be exposed to the sun. Since sunlight |
|
|
|
|
|
|
|
|
|
|
|
| may affect photoelectric sensors, you should mount the |
|
|
|
|
|
|
|
|
|
|
|
| sending unit (not the receiving unit) on the side of the |
|
|
|
|
|
|
|
|
|
|
|
| door opening most exposed to the sun. |
|
|
|
|
|
|
|
|
|
|
|
| NOTE: If wires must be lengthened or spliced into |
|
|
|
|
|
|
|
|
|
|
|
| prewired installation, use wire nuts or suitable con- |
|
|
|
|
|
|
|
| SENDING UNIT |
| |
| nectors. |
|
|
|
|
| LED ALIGNMENT | HAS NO LED |
| |||
|
|
|
|
|
|
| LIGHT | LIGHT |
| |||
| Attach the sending and receiving units to the “U” brack- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| ets by inserting their tabs into the respective holes. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| TAB HOLES |
|
|
| ||||||
|
|
|
|
|
|
| ||||||
|
|
|
| BOTTOM & TOP |
|
|
| |||||
|
|
|
|
|
|
|
|
| TABS |
| ||
|
|
|
|
|
|
|
|
| BOTTOM & TOP |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
19