Wayne-Dalton 3982 Changing the wall station’s security code, Wall Station Programming

Page 24
Changing the wall station’s security code:

Step 23: Wall Station Security Code Change and Programming

NOTE: The user must change the wall station’s security code before using the wall station.

This code setting sequence is only required the first time the wall station is used.

Overview: When changing the wall station’s security code, the user will have to hold the light button down for approximately 10 seconds, then release the button momentarily, and finally hold the button down again for approximately 5 seconds.

Changing the wall station’s security code:

1.Press and hold the wall station’s light button for ap- proximately 10 seconds until the wall station’s LED begins to blink rapidly. Once the LED starts blinking release the wall station’s light button; the LED will turn off.

2.Press and hold the wall station’s light button again (LED will light) for approximately 5 seconds. After approximately 5 seconds the LED will begin to blink on and off. Release the light button. The wall station’s LED will blink on and off three times indicating a suc- cessful security code change.

The wall station is now ready to be programmed to the opener.

LIGHT BUTTON

LED

Wall Station Programming

To program wall station:

1.Verify the emergency disconnect handle is in the manual door operated position (lower position). This is for safety reasons.

2.On the front cover of the opener, press and release the red program button; the opener will beep once, indicating activation of the program mode. The opener will remain in program mode for 30 seconds.

3.Press and hold the wall station light button until the opener beeps one time. The wall station is now programmed.

4.Return the emergency disconnect handle to the mo- tor operated position (upper position).

No beeping response of the opener during the wall station programming indicates a programming failure. Repeat programming Steps 1-4.

NOTE: Programming failure can occur during the wall station programming if the remote control is too close to the opener during the programming sequence. Perform the programming with a minimum of six feet between the remote control and the opener.

MOTOR IN UP POSITION

OPENER

RED PROGRAM

BUTTON

LIGHT

HANDLE IN MANUAL OP- BUTTON

ERATED POSITION

24

Image 24
Contents Important Notice Model 3982 idrive Extension Spring KitTable of Contents System RequirementsFCC and IC Statement FCC Regulatory InformationINSTALLATION AND USE INSTALLATION AND USEHardware Kit: 3982 idrive Extension Spring Kit idrive Package Contents idrive Hardware KitAvailable Accessories: For idrive Tools Neededidrive Retro-fitInstallation Extension idrive InstallationStep 1: Extension Spring Relief Step 2: Remove Front SheaveStep 4: Flag Bracket Installation Step 4A: Track Width ConformationNOTE: In some instances there shown in stepStep 5: Cable Drum Installation Step 6 Bottom Bracket Lifting CablesNOTE Do not remove shrink wrap from cable drums until instructed to do soStep 7: Drum Wrap Installation Step 8 Extension Spring Counterbalancewrapped oppositely on the drum Step 9: Safety Cable Installation Step 10 Lower the DoorWARNING TO AVOID SEVERE IN JURY DO NOT PLACE FINGERS OR HANDStep 11: idrive Opener/Torque Tube Assembly NOTE Hold the opener by the mainbody. Do not hold by the motor NOTE: Do not force the opener ontoStep 13: Secure idrive Opener Step 14: Disconnect Installation tion be pilot drilled using 1/8” drill bitNOTE: It is recommended that 1/4” lag screw loca and Owner’s ManualPre-OperationInstallation Step 15: Wall Station InstallationSwitch Settings Light Fixture Jumper Settings: OpenerStep 16 Multi-Opener/LightFixture Programming Step 17: Light Fixture Installation CEILING MOUNTINGLight Fixture Installation Continued power back on at fuse boxWALL MOUNTING Step 18: Photoelectric Safety Sensor Installation NOTE: If wires must be lengthened or spliced intonectors Photoelectric Safety Sensor Installation ContinuedStep 19: Power Connection Standard Wiring CONVENIENT POWER OUTLETLIGHT FIXTURE POWER OUTLET RECEPTACLE #6 X 7/8 WOOD SCREWS POWER CORD FEMALE END OPENERStep 20 Power Connection Permanent Wiring Option Step 22: Photoelectric Safety Sensor Alignment Step 21 Securing the OpenerChanging the wall station’s security code Wall Station ProgrammingStep 24 Install Routine MOTOR OPERATED POSITIONUP/DOWN BUTTON PROFILE BUTTON Step 25: Detent Adjustment if required Step 26: Lock Arm InstallationStep 27: Custom Settings Step 28 Photoelectric Obstruction Sensor Test Step 29: Contact Obstruction TestStep 30: Transmitter Security Code Change and ProgrammingCHANGING THE TRANSMITTER’S SECURITY CODE TRANSMITTER PROGRAMMINGTeaching Power Unit Step 31: Programming HomeLink to idriveper Step PROGRAMMING Training HomeLink UnitImportant Safety Instructions 8.SAVE THESE INSTRUCTIONSOperation Transmitter Operationservice person immediately Wall Station OperationManual Door Operation Emergency Disconnect MOTOR DOWN POSITION DOOR LOCKEDDISCONNECTED, MOTOR UP POSITION Maintenance Monthly MaintenanceBattery replacement NOTE: Dispose of dead batteries properlyTroubleshooting SYMPTOMPROBABLE CAUSE CORRECTIVE ACTIONTroubleshooting continued Lock Arm TroubleshootingSYMPTOM SYMPTOMWayne-DaltonCustomer Service LIFETIME LIMITED WARRANTYQuestions?? For quick answers and helpful advise, call