Installation

 

 

Outside Air

 

 

To install outside air, use 2 3/4” I.D.galvanized

 

 

steel flex pipe, part # 2-00-08544 ( 12’6” length) or part

 

 

# 2-00-08545 ( 25’ length) See Fig. 6. There is a break-

 

 

away hole on the rear panel which must be removed

 

 

before connecting the flex pipe. See Fig. 7.

 

 

When the appliance is side wall vented: The air

 

 

intake is best located on the same exterior wall as the

 

 

exhaust vent outlet, and located lower on the wall than

 

 

the vent outlet.

 

 

When the appliance is roof vented: The air intake

Inlet Cover part#

Fig. 6

is best located on the exterior wall oriented toward the

1-10-09542

prevailing wind direction during the heating season.

 

 

Never terminate the outside air above the vent pipe

 

 

outlet. The maximum length of this pipe is 20 feet. Inlet

 

 

cover part number 1-10-09542 should be used to keep

 

 

birds, rodents etc.out of the inlet pipe. See Fig.6.

 

 

NOTE: The inlet cover should not be placed in an

Outside Air Pipe

 

area where drifting of snow or ice will build up, block-

 

ing the intake air supply.

Knockout

 

 

 

The Outside Air knockout is located on the face of

 

 

the Feeder Cover. It is pre-cut except for several small

Feeder Cover

 

tabs. There is also a filler plate screwed to the inside

 

 

to cover the top of the hole after the Outside Air Pipe

 

 

has been installed. This will allow for removal of the

 

 

Feeder Cover without disconnecting the Outside Air

 

 

Pipe. See Fig. 7.

Fig. 7

 

Only metal Intake Flex should be used for the

 

Outside Air Supply connection.

 

 

 

 

The Outside Air Intake Pipe is inside the Feeder

 

 

Cover and to the right of the feeder motor. The 2 3/4”

 

 

steel flex pipe is made to slide over the outside of the

 

 

Air Intake Pipe. See Fig. 8. It should be held into place

 

 

with some silicone, foil tape, or a hose clamp. (not

Outside Air Inlet Pipe

 

supplied)

 

Heat Reclaiming Ventilation System (HRV)

 

When installing in a house with a Heat Reclaim-

 

ing Ventilation System (HRV) be sure the system is

 

balanced and is not creating a negative pressure in the

Hopper/Feeder

house.

Swing Plate

 

Knob

 

Fig. 8

13

Image 13
Contents Harman PB 105 Pellet Boiler Installation & Operating ManualPage Parts Locations Report # 135-S-16-6 IntroductionHarman Central Heating Products Limited Warranty WarrantyBoiler Kit Materials Refer to AssemblyDesign Installation is to be Performed by a Qualified Installer Venting Venting Venting Ventingti gKeep combustibles away From flue outlet Venting InstallationOutside Air Main Wiring Installation InstallingInstallationDuct Installing Duct/AirInstallationConditioning Example of Typical Tankless Domestic HOT Water Piping InstallationUnion AIR Vent Installation Power Failure / Heat Dissipation Loop Over Heat Safety ZoneTest Draft Test ProcedureFuel and Fuel Storage Fuel SpecificationsStatus Light OperationWithout the Outdoor Air Temperature Sensor Installed Setting The Boiler TemperaturePellet Boiler Outdoor Air Reset Operation Starting a Fire Automatically Turn Mode Selector to OFFMAX. Temp Flip the Igniter Switch up into the Auto positionHave matches or other ignition source ready Lighting a Fire ManuallyOperation Burnpot Cleaning MaintenanceFeeder Chamber Fig To remove the feeder coverRemove Ash Pan Open Ash DoorCleaning Steps Combustion Blower Cleaning Helpful Hints TroubleshootingFuel Atmospheric Conversion Pb105 #8 Ash base Assembly Pb105 #28 Feeder Assembly Stocked at depot BTU Input Range= 0, and 9350 to 113,900 SpecificationsElectrical 120 VAC 60 Hz Pellet Boiler Wiring Diagram DiagramPower Failure Backup Supply Exceeding -.9 in Water Column / -224Pa Testing LabelService Record / Notes Service Record / Notes Proudly Printed On 100% Recycled Paper Quick Reference Auto-Light