Harman Stove Company PB 105 Installation, Example of Typical Tankless Domestic HOT Water Piping

Page 17

Installation

EXAMPLE OF TYPICAL TANKLESS DOMESTIC HOT WATER PIPING

HIGH TEMPERATURE

TEMPERED HOT WATER TO

WATER (IF NEEDED)

SHOWERS AND FAUCETS

 

OPTIONAL DOMESTIC

HOT WATER COIL

INLET

OUTLET

AQUASTAT WELL LOCATION

HOSE BIB TO BACKFLUSH COIL IF NEEDED

FLOW REGULATOR

HOSE BIB

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS

RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER

MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.

MIXING VALVE

MIXING VALVE SET TO DESIRED WATER TEMPERATURE.

NORMALLY NOT MORE THAN 120 DEGREES.

SAFETY RELIEF VALVE

ISOLATION VALVE

COLD WATER SUPPLY

FLOW REGULATOR WILL NEED TO MATCH THE GPM RATING OF THE DOMESTIC COIL. (IF USING A DOMESTIC COIL, 4 GPM IS REQUIRED.)

EXAMPLES OF TYPICAL DOMESTIC HOT WATER STORAGE PIPING

EXAMPLE #1

EXAMPLE #2

FROM BOILER

FROM BOILER

HIGHER TEMPERATURE

WATER (IF NEEDED)

CIRCULATOR

TO BOILER

COLD HOT

DOMESTIC HOT WATER STORAGE HEATER

IN

OUT

CIRCULATOR

TO BOILER

COLD HOT

DOMESTIC HOT WATER STORAGE HEATER

IN

OUT

TEMPERED HOT WATER FOR

SHOWERS AND FAUCETS

MIXING VALVE

MIXING VALVE SET TO DESIRED WATER TEMPERATURE.

NORMALLY NOT MORE THAN 120 DEGREES.

NOTE: ALWAYS REFER TO THE INDIVIDUAL COMPONENTS RECOMMENDED INSTALLATION INSTRUCTIONS FOR THE PROPER MOUNTING POSITION AND LOCATION WITHIN THE PIPING SYSTEM.

NOTE:TYPICALLY, AS LONG AS THE WATER TEMPERATURE NEEDED IS NOT MORE THAN 120F,THE MIXING VALVE SHOWN ABOVE (EXAMPLE 2) IS NOT NEEDED

17

Image 17
Contents Harman PB 105 Pellet Boiler Installation & Operating ManualPage Parts Locations Report # 135-S-16-6 IntroductionHarman Central Heating Products Limited Warranty WarrantyBoiler Kit Materials Refer to AssemblyDesign Installation is to be Performed by a Qualified Installer Venting Venting Venting Ventingti gKeep combustibles away From flue outlet Venting InstallationOutside Air Main Wiring Installation InstallingInstallationDuct Installing Duct/AirInstallationConditioning Example of Typical Tankless Domestic HOT Water Piping InstallationUnion AIR Vent Installation Power Failure / Heat Dissipation Loop Over Heat Safety ZoneTest Draft Test ProcedureFuel and Fuel Storage Fuel SpecificationsStatus Light OperationWithout the Outdoor Air Temperature Sensor Installed Setting The Boiler TemperaturePellet Boiler Outdoor Air Reset Operation Starting a Fire Automatically Turn Mode Selector to OFFMAX. Temp Flip the Igniter Switch up into the Auto positionHave matches or other ignition source ready Lighting a Fire ManuallyOperation Burnpot Cleaning MaintenanceFeeder Chamber Fig To remove the feeder coverRemove Ash Pan Open Ash DoorCleaning Steps Combustion Blower Cleaning Fuel TroubleshootingHelpful Hints Atmospheric Conversion Pb105 #8 Ash base Assembly Pb105 #28 Feeder Assembly Stocked at depot Electrical 120 VAC 60 Hz SpecificationsBTU Input Range= 0, and 9350 to 113,900 Pellet Boiler Wiring Diagram DiagramPower Failure Backup Supply Exceeding -.9 in Water Column / -224Pa Testing LabelService Record / Notes Service Record / Notes Proudly Printed On 100% Recycled Paper Quick Reference Auto-Light