Heat & Glo LifeStyle TIARAP-CTO, TIARAP-CES, TIARAP-BK owner manual What to do if you smell gas

Page 1

Owner’s Manual

Installation and Operation

TIARA PETITE B

DIRECT VENT ROOM HEATER

Model:

TIARAP-BK

TIARAP-BR

TIARAP-CES

TIARAP-CTO

Tested and

O-T L

Portland

Listed by

Oregon USA

 

C

US

OMNI-Test Laboratories, Inc.

CAUTION

DO NOT DISCARD THIS MANUAL

• Important operating and •

Read, understand and

• Leave this manual with

maintenance instructions

follow these instructions

party responsible for use

included.

for safe installation and

and operation.

 

operation.

 

DO DISCARDNOT

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas

-Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory-trained professionals, or technicians supervised by an NFI certified professional.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

Do not touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in the same room as appliance

Alert children and adults to hazards of high

temperatures

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other combustibles away.

In the Commonwealth of Massachusetts:

installation must be performed by a licensed plumber or gas fitter.

See Table of Contents for additional Commonwealth of Mas- sachusetts requirements.

This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer's instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH.

This appliance is only for use with the type(s) of gas indicated on the rating plate.

www.heatnglo.com

7026-101K

August 1, 2008

Image 1
Contents What to do if you smell gas Installation and OperationHot glass will cause burns Location Hang tag attached to rear of appliance CongratulationsTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Getting Started Design & Installation ConsiderationsTools and Supplies Needed Inspect Appliance & ComponentsSelecting Appliance Location Appliance Location and ClearancesClearances to Combustibles Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsVenting Guidelines How to Use the Vent GraphStep Horizontal Termination203mm Vinyl Siding Direct Vent Pipe Vertical TerminationCeiling Joists Framing 2 in mm Long Wood Screws Twist-lock the vent cap and seal Level Cathedral Ceiling Support Box Cathedral CeilingClass a Metal Chimney Type a & B Co-Axial to Co-Linear Type C Up & Out InstallationExisting Masonry Chimney Type D Hearth MountCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Slim Line Wall Thimble Installing Slim Line Trim Ring and Heat ShieldAssembling Slim Line Trim Ring and Heat Shield NextFIG. C Minimum Clearance Gas Information Wire clipFuel Conversions Converting to LP GasScrews Rubber Gasket Identification Label F Valve Regulator ReplacementGas Connection Gas PressuresHigh Altitude Installations Connecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Wire Size Max. LengthTo access the module Ignition Module Access and Battery ReplacementRemove Shipping Materials Flue Restrictor Installation Appliance SetupLeg Leveling System Intake Damper Operation Positioning the Logs Intake Air Shutter AdjustmentMineral Wool AccessoriesKIT Contents Blower InstallationAugust 1 Heat & Glo · Tiara Petite B · 7026-101K 19 Complete Assembly Glass Replacement Warming Shelves InstallationBefore Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramSL-D Series Vent Components Vent Components DiagramHHT SL-P Vent Components ListTermination Caps & Kits Description Tiara Petite BService Parts List cont’d. Tiara Petite B Tiara Petite B Cast Parts Individual Pieces Accessories Date of Service Performed By Description of Service Service and Maintenance LogLimited Lifetime Warranty Heat & GLO GAS Appliance Products Warranty PolicyContact Information Tiara Petite BDealer Telephone