Read this manual before installing or operating this appliance.

Please retain this owner's manual for future reference.

Congratulations

Congratulations on selecting a Heat & Glo gas appliance - an elegant and clean alternative to wood burning appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new appliance, you'll want to read and carefully follow all of the instructions contained in this Owner's Manual. Pay special attention to all Cautions and Warnings.

This Owner's Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

The information contained in this Owner's Manual, unless noted otherwise, applies to all models and gas control systems.

Your new Heat & Glo gas appliance will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of gas appliance products!

SAMPLE OF RATINGS LABEL

LOCATION: Hang tag attached to rear of appliance.

 

 

 

 

 

 

 

 

Serial No / Numéro du

 

 

Tested and

O-T L

Portland

 

 

MODEL / MODÈLE: TIARA PETITE (B)

 

007

 

 

 

 

 

VENTED GAS FIREPLACE HEATER

 

 

 

 

Listed by

Oregon USA

 

 

 

 

 

 

 

C

US

 

NOT FOR USE WITH SOLID FUEL

 

 

 

 

 

OMNI-Test Laboratories, Inc.

 

 

 

A division of Hearth & Home Technologies Inc.

 

 

Report No. / Rapport Numéro

 

 

 

 

 

 

 

FOURNAISE AU GAZ AVEC VENTILATION

 

 

20802 Kensington Boulevard

 

 

 

061-S-47b-5

 

NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE

 

 

Lakeville, MN 55044

 

 

 

 

 

 

 

 

 

 

 

 

APPROVED FOR CANADAAND USA TO: ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heaters, and applicable sections of UL307b Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91 Gas Fired Appliances for use at High Altitudes. This appliance is manufactured for operation with Natural Gas. For conversion to propane Manufacturer's instructions must be used. This appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is required.

APPROUVÉ-POUR LE CANADAET LES ÉTATS-UNIS:ANSI-Z21.88b-2003 / CSA 2.33b-2003 Fournaises au Gaz avec Ventilation, et les sections applicable de UL 307b Appareils de Chauffage Au Gaz our les Maisons Mobiles et les Vehicules Motoriss, CAN/CGA2.17-M91 Gas FiredAppliances for use at HighAltitudes. Cet appareil est manufactur pour l'operation avec le Gaz Naturel. Pour une conversion au gaz propane les pices du Manufacturier et ses instructions doivent tre utilises. Cet appareil peut tre utilis dans une chambre à coucher ou salle de sjour, au Canada, l'installation d'un thermostat à distance est exige.

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE

Blower Electrical Rating / Evaluation du Ventilateur

115 V., .55 Amps, 60 Hz, 150 Watts

 

P.4.1-02 Canada Minimum pipe (P.4.1-02 Le Canada tuyau minimum) 67.38% NG / 69.52% LP

Blower is Optional. Order Part #844-9370

 

 

 

Route power cord away from unit. Do not route

 

 

 

power cord under or over stove./Éloignez le fil électrique

 

 

 

de l'appareil. Ne pas faire passer le fil électrique au dessus

For use with Natural Gas

For use with Propane

 

ou en dessous de l'appareil.

Usage Au Gaz Naturel

Usage Au Gaz Propane

 

 

0-2000 FT’

0-2000FT

 

Input Rate on “HI” (BTU/Hr)

17,000

17,000

Puissance Évaluée à “HI” (BTU/Hr)

Input Rate on “LO” (BTU/Hr)

12,000

13,000

Puissance Évaluée à “LO” (BTU/Hr)

Maximum Output (BTU/Hr)**

14,500

13,500

Puissance Maximum (BTU/Hr**

Main Burner Orifice

49

56

Orifice du Brûleur Principal

Minimum Inlet Pressure (Inches W.C.)

4.5”

11”

Pression Minimum de la Valve (pouces W.C.)

Maximum Inlet Pressure (Inches W.C.)

7.0”

14”

Pression Maximum de la Valve (pouces W.C.)

Manifold Pressure on “HI” (Inches W.C.)

3.5”

10”

Pression du Collecteur d’ Échappement à “HI” (pouces W.C.)

**Max Venting, Blower On

 

 

**Ventilation Maximum, Ventilateur Allumé

This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent configuration, orifice or combination of both may need to be changed. See Owner’s Manual for information on making these changes. This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow ANSI Z223.1 in USA, CAN 1-B149 in Canada. Install and use only in accordance with manufacturer’s installation and operating instructions. NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.) / Cet appareil est équipé pour les altitudes de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propriétaire pour les informations sur ces changements. Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez ANSI Z223.1/CAN 1-B149. Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier. REMARQUE: Le conduit gaz doit être installé conformément aux codes de construction locaux. L'installation doit être effectuée par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la République de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.)

MINIMUM CLEARANCES TO COMBUSTIBLES / ESPACE MINIMUM AUX COMBUSTIBLES

Minimum clearances required from combustible construction for all appliance surfaces. /

Espaces minimum exigés de la construction combustible aux surfaces de l’appareil.

 

 

F

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRight

 

 

 

G

A

A

A

A

 

D

 

 

E

 

 

 

 

 

 

C

 

 

 

 

 

Left

 

 

"A" measurement is from

 

 

 

 

stove top, not side

 

 

 

 

A.

Side of stove top to side wall

6" (15cm)

Du coté du poêle au coté du mur

 

B.

Rear of stove to back wall

2" (5cm)

Le contrôle arrière au mur arrière

 

C.

Corner of stove top to side wall-Left

2" (5cm)

Du coin arrière du poêle au mur de coté gauche

C.

Corner of stove top to side wall-Right

2" (5cm)

Du coin du dessus du poêle au mur de coté droit (acces a la valve)

D.

Minimum Alcove Height

 

43" (109cm)

Hauteur minimum du plancher au plafond

 

E.

Maximum Alcove Depth

 

36" (91cm)

Profondeur maximum de l'alcove

 

F.

Minimum Alcove Width

 

30" (76cm)

Largeur minimum de l'alcove

 

G.

Mantle Clearance from stove top

19-1/2" (50cm)

Espace libre du poêle au manteau

 

H.

Top of Stove to Alcove Ceiling

20-1/4" (51cm)

Dessus de fourneau au plafond de chambrette

HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and strong enough to support the stove without a tipping hazard.

CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle sans le hasard de basculer.

Date of Manufacture /

Date du Manufacturier

 

 

2008 2009 2010 Jan Feb Mar Apr

May

Jun

Jul

Aug Sep

Oct Nov Dec

 

 

 

 

 

102

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE

 

Made in U.S.A. / Fait Aux États-Unis

7026-

Serial No.

Barcode

Model Name

Test Lab & Report No.

Manufactured Date

Page 2

Heat & Glo · Tiara Petite B · 7026-101J

August 1, 2008

Image 2
Contents Hot glass will cause burns Installation and OperationWhat to do if you smell gas Congratulations Location Hang tag attached to rear of applianceTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Tools and Supplies Needed Design & Installation ConsiderationsGetting Started Inspect Appliance & ComponentsClearances to Combustibles Appliance Location and ClearancesSelecting Appliance Location 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsHow to Use the Vent Graph Venting GuidelinesHorizontal Termination Step203mm Vinyl Siding Vertical Termination Direct Vent PipeCeiling Joists Framing 2 in mm Long Wood Screws Twist-lock the vent cap and seal Cathedral Ceiling Level Cathedral Ceiling Support BoxClass a Metal Chimney Existing Masonry Chimney Type C Up & Out InstallationType a & B Co-Axial to Co-Linear Type D Hearth MountCut and bend flashing as needed to fit Sealant adhesive Flex Liner Flex Coupler Sheet Metal Screws Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble NextFIG. C Minimum Clearance Fuel Conversions Wire clipGas Information Converting to LP GasValve Regulator Replacement Screws Rubber Gasket Identification Label FGas Pressures Gas ConnectionHigh Altitude Installations Standing Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthIgnition Module Access and Battery Replacement To access the moduleLeg Leveling System Appliance SetupRemove Shipping Materials Flue Restrictor Installation Intake Air Shutter Adjustment Intake Damper Operation Positioning the LogsAccessories Mineral WoolBlower Installation KIT ContentsAugust 1 Heat & Glo · Tiara Petite B · 7026-101K 19 Complete Assembly Warming Shelves Installation Glass ReplacementControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram SL-D Series Vent ComponentsVent Components List HHT SL-PTermination Caps & Kits Tiara Petite B DescriptionService Parts List cont’d. Tiara Petite B Tiara Petite B Cast Parts Individual Pieces Accessories Service and Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsDealer Telephone Tiara Petite BContact Information